Bosch Appliances DVR DVR600 User Manual

Security Systems  
Product  
Document type  
Release #  
V2.0.7  
SAP/Doc number  
Release date  
DVR 600 Series  
Release notes  
2013.02.12  
Video Recorder 600 Series new firmware version  
1 DVR 600 Series firmware version 2.0.7 (date 2013-02-08)  
File name: 600series.bin (2013-02-08)  
This release includes the following improvement:  
Removed some wanIP providers that are not available anymore to solve issues with  
some DynDNS providers  
Corrected web site for DDNS server ‘sitelutions’.  
Solved issue that sometimes after several connection losses the system does not allow  
to reconnect again until power cycling the DVR.  
Security update for mobile devices.  
Bosch strongly recommends upgrading to the latest firmware to  
achieve the best possible functionality, compatibility and  
performance.  
2 Update procedure  
To update the DVR 600 Series to the latest firmware, please refer to the Video recorder 600  
Series Operation Manual, chapter 6.6.5 or follow instructions below:  
1. Put firmware v2.0.7 via a PC on the root of a USB memory stick (file name: 600series.bin  
[date 2013-02-08])  
2. Insert the USB stick into the front USB connector of the DVR  
3. Log on as “ADMINISTRATOR” in the local unit  
4. Select Menu and go to the “System > Configuration” screen  
5. Select Update firmware to upgrade the DVR software. In this case, the current DVR  
settings and video will not be deleted or replaced during the update process.  
Figure: Update firmware menu  
Page 1 of 6  
 
Security Systems  
Product  
Document type  
Release #  
V2.0.7  
SAP/Doc number  
Release date  
DVR 600 Series  
Release notes  
2013.02.12  
o This port number is now user selectable.  
This release includes the following bug fixes were below issues are solved:  
In low or unstable network configurations the DVR sometimes block any network user  
access until the unit was power cycled.  
It was not possible to record a tour in G3 domes via DVR.  
DVR was losing network gateway in some network applications.  
Network connection was not possible immediately after network disconnect.  
DVR ID in web pages showed one number higher than set in DVR.  
DVR rebooted after a number of smart search actions in web interface.  
3.4 Version 2.0.1  
File name: 600series.bin (2012-03-23)  
This release includes the following improvement:  
Web browser support for DVR 600 Series on IE9  
Option to avoid ICMP ping with Control Center (requires CC release v3.35)  
o Important note:  
.
.
.
In the new firmware you can set the ICMP to On or Off in the local UI  
menu ‘Network-TCP/IP’  
ICMP must set to On to get the DVR connected to a CC version 3.34 or  
older because in this version of Control Center the ICMP is required  
In the new Control Center version 3.35 the ICMP is not required  
anymore, therefore in this CC version you can set ICMP to Off in the  
local UI menu ‘Network-TCP/IP’  
Email notification with a 10 seconds video clip (10 pictures, iFrame only)  
Low bandwidth support by selecting 256/512kbps bandwidth throttle (iFrame only mode  
when selecting bandwidth of 256 or 512kbps in local UI)  
PAL or NTSC video format detection is improved (user will be clearly notified when  
video format of DVR don’t match with video format of connected cameras).  
Improve PTZ handling in full screen (you can select Menu, Search, Export or Exit when  
PTZ control is active)  
Video playback from HDD mounted in other DVR600 (possible to move complete HDD  
set from one to another DVR600)  
Avoid invalid log-on when user ID is used special characters like /:@ (In this firmware  
these characters are grayed out and cannot be selected)  
Give warning/possible to cancel before delete video after video format (NTSC/PAL)  
change  
This release includes the following bug fixes were below issues are solved:  
It is possible to use AUX on/off function in Control Center version 3.35  
Correct AM/PM setting using export via web when DVR is set in 24h mode  
Dome never stop moving if using PTZ control and drag mouse point  
Page 3 of 6  
 
Security Systems  
Product  
Document type  
Release #  
V2.0.7  
SAP/Doc number  
Release date  
DVR 600 Series  
Release notes  
2013.02.12  
Recording channel led off if used HDD is not certified  
File name: 600series.bin (2012-04-20)  
3.5 Version 2.0.2  
File name: 600series.bin (2012-04-20)  
This release includes the following bug fixes:  
Export via web access is not possible when logged-on as 'Advanced User' or 'Normal  
user’ that has rights for export. Always an error is stating that the export file contains  
0MB. This has been solved.  
Changing the additional “Normal user settings (like allow playback, search) via the web  
access was not possible. This is also solved in this release.  
The status information (like video loss, motion alarm, log-on,..) is not shown at the  
bottom of the Control Center 3.35 in combination with v2.0.1. This is corrected in v2.0.2.  
3.6 Version 2.0.3  
File name: 600series.bin (2012-06-28)  
This release includes the following improvement:  
Added Traditional Chinese language in the local user interface.  
3.7 Version 2.0.4  
File name: 600series.bin (2012-09-13)  
This release includes the following bug fixes:  
Video can be playback but export is not possible. When trying to export the video the  
system indicate that there is no video found. This has been solved.  
This firmware adds a watch dog feature which in the unlikely case of SW error triggers a  
restart to guarantee reliable operation throughout the units’ lifetime. We recommend that  
customers update their DVR units to the newest FW to benefit from this protection layer.  
3.8 Version 2.0.5  
File name: 600series.bin (2012-09-18)  
This release includes the following improvement:  
Improve compatibility with Late Configuration tool version 2.7. No functional changes  
compared to previous DVR630/650 firmware version 2.0.4.  
Page 4 of 6  
 
Security Systems  
Product  
Document type  
Release #  
V2.0.7  
SAP/Doc number  
Release date  
DVR 600 Series  
Release notes  
2013.02.12  
3.9 Version 2.0.6  
File name: 600series.bin (2012-10-12)  
This release includes the following improvement:  
In this version unsigned hard disk drives are supported.  
The below drives are released and recommended for use in the DVR630/650. These are  
available from Bosch Security Systems as DVR-XSxx0-A Storage Expansion Kits.  
We do not test other drives than indicated above to verify reliability:  
When using non-Bosch drives in DVR630/650 Series recorders, Bosch can no  
longer be held liable for any loss or damages or system mal-function resulting  
from the use of non-Bosch drives.  
Bosch will provide advance exchange and carry in service only on Bosch  
products. This means that failing DVR630/650 Series recorders should be  
returned for repair without non-Bosch drives.  
Should non-Bosch hard disk drives be returned, then Bosch will not be held  
responsible for loss of these drives or any information recorded on these drives  
or for any consequential damages.  
Bosch will not be held liable for loss or consequential damages resulting from  
disclosure of any information stored on these non-Bosch drives.  
Remote export on low bandwidth networks are supported in this version.  
Note 1  
Issue: Web access log-on as “Normal user” that has rights for playback. Still the playback icon  
is grayed out and cannot be pressed.  
Solution: You can select additional rights for Play, Search, Export and Alarm acknowledge for a  
“Normal user”. However to give additional ‘Play’ rights you also have to give additional ‘Search’  
rights. You cannot have ‘Play’ rights without also having ‘Search’ rights activated.  
Note 2  
Issue: Uploading DVR 400/600 firmware via webpage using IE, can cause unexpected error  
message "DVR update file contains errors" as result of IE security settings.  
Solution: Enable "Include local directory path when uploading files to a server".  
In IE9 this setting can be found in "tools", "Internet options", "Security", "Custom level",  
"Miscellaneous", "Include local directory path when uploading files to a server". Enable this  
setting to make uploading DVR400/600 firmware possible.  
Page 5 of 6  
 
Security Systems  
Product  
Document type  
Release #  
V2.0.7  
SAP/Doc number  
Release date  
DVR 600 Series  
Release notes  
2013.02.12  
Note 3  
The CC only shows maximum one event per second. So if more events are generated within  
one second only the last event is shown. On the local unit always all events are shown.  
Page 6 of 6  
 

Belkin Mouse F8U1500 User Manual
Black Decker Oven TRO910B User Manual
Britax Car Seat P321900 User Manual
Cabletron Systems Water Dispenser 1800 User Manual
Campbell Hausfeld Air Compressor VH300300 User Manual
Capcom Video Game Controller SF4 4728 MUG User Manual
Casio Watch MA0409 EA User Manual
Casio Watch MA0606 EA User Manual
Char Broil Gas Heater 4984619 User Manual
Chromalox Electric Heater STAR 05A User Manual