Honeywell Thermostat 08161 User Manual

08161  
TH110-DP-P  
TL8230  
1.  
3.  
Description  
Configuration  
n
p
The configuration switches are on the back of the thermostat. Default (factory)  
settings are inside the gray cells.  
This programmable thermostat can be connected to an electric heating sys-  
tem such as an electric baseboard, a radiant ceiling, a floor heating system,  
an electric convector, etc. It is not compatible with a central heating system.  
#
Configurations  
Not used  
UP  
DN  
SW1  
SW2  
SW3  
SW4  
Early Start a  
Time format  
Disable  
12-hour  
°F  
Enable  
24-hour  
°C  
Time and day  
Appears during the  
Temperature format b  
setpoint display  
On/Off  
switch  
a. Early Start can be used in Automatic mode only. When this function is  
enabled, the thermostat calculates the optimal time to start heating in  
order to obtain the desired temperature by the set time. The thermostat  
re-assesses the start time daily based on the previous day’s perfor-  
mance.  
Temperature  
Operating  
mode icons  
Preset temperature  
icons  
Heating  
indicator  
To set the day  
To set the time  
b. If you change the temperature display format, the preset temperatures  
(
,
and ) will return to their default settings.  
Periods  
4.  
To program the schedule  
To skip a period  
Temperature  
preset buttons  
Power-up  
q
Upon power-up, the thermostat is in manual mode ( ) and displays the room  
temperature.  
To select the  
operating mode  
Temperature  
adjustment  
n Press the Hour and Min buttons to set the thermostat’s clock.  
o Press the Day button to set the day.  
5.  
*
Set the switch to Off to cut power to the heater. This will not affect the time and tem-  
Temperature Setting  
perature settings.  
r
2.  
Setpoint  
Connection  
The thermostat normally displays the room temperature. To view the set tem-  
o
perature, press the  
5 seconds.  
or  
button briefly. The set temperature will appear for  
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER  
PANEL TO AVOID ELECTRICAL SHOCK.  
To change the setpoint, press the  
is displayed. To scroll faster, hold the button.  
or button until the desired temperature  
The installation must be carried out by an electrician.  
All cables and connections must conform to the local electrical code.  
Using a preset temperature  
Special CO/ALR solderless connectors must be used when connecting  
with aluminum conductors.  
The thermostat has 3 preset temperatures:  
Comfort temperature  
Economy temperature  
Vacation temperature  
Install the thermostat onto an electrical box.  
Install the thermostat about 5 feet high, on an inside wall facing the  
heater.  
Avoid locations where there are air drafts (such as the top of a staircase  
or an air outlet), dead air spots (such as behind a door), or direct sun-  
light.  
Icon  
Intended use  
Default setting  
Comfort (when at home)  
70 °F (21 °C)  
Do not install the thermostat on a wall that conceals chimney or stove  
pipes.  
Economy (when asleep or away from home)  
Vacation (during prolonged absence)  
62 °F (16 °C)  
50 °F (10 °C)  
n Connect the thermostat wires to the  
Black  
Red  
power and to the load using solderless  
connectors for copper wires.  
Power  
Load  
To use the Comfort or Economy temperature, press the  
respectively. The corresponding icon will be displayed.  
or button  
o Push the excess wire back into the  
To use the Vacation temperature, press both  
neously. The icon will be displayed.  
and buttons simulta-  
electrical box to prevent interference  
with the thermostat.  
Storing a preset temperature  
p Secure the thermostat using two 6-32  
To store the Comfort or Economy temperature:  
screws.  
Set the desired temperature using the  
the appropriate button ( or ) for approximately 3 seconds until the  
corresponding icon is displayed.  
or button. Press and hold  
q Return power to heating system.  
NOTE: Always keep the thermostat's vents  
clean and unobstructed.  
To store the Vacation temperature:  
Set the desired temperature using the  
both  
the  
or button. Press and hold  
and buttons simultaneously for approximately 3 seconds until  
icon is displayed.  
Load  
08161 / TH110-DP-P / TL8230  
69-2023-01  
2010-02-05  
1/2  
Programmable Thermostat - Installation and User Guide  
 

Graco Inc Paint Sprayer ti8370a User Manual
Graco Marine Battery 256991 User Manual
Greenheck Fan Ventilation Hood QEM User Manual
Hafler Stereo Amplifier GX2300 User Manual
Haier Washer HWM80 0626S User Manual
Harbor Freight Tools Paint Sprayer 95690 User Manual
Hasbro Games 55312 User Manual
Hotpoint Dishwasher FDW85 User Manual
HTC Cell Phone NMRHOD00 User Manual
Hunter Fan Fan 18865 User Manual