R7184
Interrupted Electronic Oil Primary
The new R7184 features interrupted ignition and valve-on delay with selectable
blower-off delay timings on selected models.
FEATURES
■ Oil-resistant plastic cover for electronics.
■ Compatible with hydronic and forced air applications.
■ Mounts on standard 4 in. by 4 in. junction box, directly
■ Patented cad cell resistance readout.
on main burner or inside appliance cabinet.
■ Available in 15- and 30-second lockout times.
■ UL Component Recognition.
■ Safe start check.
■ CUL Component Recognition.
■ Status indicator light monitors burner flame status and
system lockout.
■ Uses proven flame detection and monitoring systems.
■ Optional valve-on delay, blower-off delay models.
– 15 second or selectable 0 or 15 second valve-on
delay.
– Zero time or selectable 0-, 2-, 4-, 6-minute blower-off
delay.
– Oil valve control.
– Compatible with power venters without integral
timers.
Copyright © 1999 Honeywell Inc.
•
All Rights Reserved
68-3033
L1
(HOT)
R7184
L1
T8600
JUMPER
T
T
FAN RELAY
LINE VOLTAGE
THERMOSTAT
OR AQUASTAT
CONTROL
L2
1
L1
(HOT)
RC
1
®
LIMIT
COOLING
G
Y
TRANSFORMER
L2
L2
R
W
COOLING
CONTROL
R7184
L1
T
1
L1
LIMIT
LIMIT
BURNER
MOTOR
BURNER
MOTOR
T
(HOT)
L2
L2
IGNITOR
IGNITOR
CAD
CELL
ALARM
2
CAD CELL
VALVE
OIL VALVE
JUNCTION BOX
BURNER
MOTOR
BURNER
MOTOR
1/4 IN. QUICK CONNECT TERMINAL
SCREW TERMINAL
LEGEND:
IGNITOR
IGNITOR
1
2
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
CAD
CELL
ALARM
M16298
2
CAD CELL
OPTIONAL FEATURE ON SELECT MODELS.
Fig. 2. Typical connection for line voltage thermostat and
R7184A for oil burner system.
JUNCTION BOX
1/4 IN. QUICK CONNECT TERMINAL
SCREW TERMINAL
LEGEND:
1
2
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
L1
(HOT)
T8600
FAN RELAY
M16300
L2
OPTIONAL FEATURE ON SELECT MODELS.
1
RC
G
COOLING
TRANSFORMER
Fig. 4. Typical connection for 24 Vac thermostat
and R7184B,P,U for valve-on delay/blower-off
delay oil burner system.
Y
COOLING
CONTROL
R
W
R7184
T
T
1
L1
L1
LIMIT
(HOT)
L2
L2
BURNER
MOTOR
BURNER
MOTOR
IGNITOR
IGNITOR
CAD
CELL
ALARM
2
CAD CELL
JUNCTION BOX
1/4 IN. QUICK CONNECT TERMINAL
SCREW TERMINAL
LEGEND:
1
2
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
OPTIONAL FEATURE ON SELECT MODELS.
M16299
Fig. 3. Typical connection for 24 Vac thermostat and
R7184A for oil burner system.
68-3033
3
Home and Building Control
Honeywell Inc.
Honeywell Plaza
Home and Building Control
Honeywell Limited-Honeywell Limitée
155 Gordon Baker Road
North York, Ontario
P.O. Box 524
M2H 3N7
Minneapolis, MN 55408-0524
Printed in U.S.A. on recycled
paper containing at least 10%
68-3033 G.R. 1-99
post-consumer paper fibers.
|