Guardian Technologies Welding System QT10068 User Manual

Standby Power Rating  
100 kW 60 Hz  
Liquid Cooled Gas Engine Generator Sets  
Whisper-Test™  
Low Speed Exercise  
61 dB(A) at 23 feet  
GENERAC 6.8L ENGINE  
Naturally Aspirated  
Gaseous Fueled  
UL 2200 Listed  
Transfer Switch is sold separately  
STANDARD EQUIPMENT  
UV/Ozone resistant hoses  
Watertight state of the art electrical connectors  
Mainline circuit breaker  
Oil drain extension to frame rail  
Radiator drain extension  
All input connections in one single area  
High coolant temperature shutdown  
Low oil pressure shutdown  
Low coolant level automatic shutdown  
Low fuel pressure  
Battery charge alternator  
Overspeed automatic shutdown  
Adjustable cranking timer  
Adjustable exercise timer  
Oil drain extension  
Cool flow radiator  
2 Amp static battery charger  
Battery, battery rack and battery cables  
Fan and belt guards  
Isochronous governor  
Flex fuel line pigtail  
Closed coolant recovery system  
FEATURES  
Built-in kW, kVAR and power factor meters  
Watertight electrical connectors  
Rodent proof construction  
High efficiency, low distortion Generac designed alternator  
Vibration isolated from mounting base  
Matching Generac transfer switches engineered and  
tested to work as a system  
All components easily accessible for maintenance  
Electrostatically applied powder paint  
Innovative design and fully prototype tested  
UL 2200 Listed  
Solid state frequency compensated voltage regulator  
Dynamic and static battery charger  
Sound attenuated acoustically designed enclosure  
Whisper-Test™ for low noise level exercise  
Acoustically designed engine cooling system  
High flow low noise factory engineered exhaust system  
State of the art digital control system with H-100  
microprocessor control panel  
COMMERCIAL SERIES  
 
COMMERCIAL 100 kW  
OPERATING DATA  
KW RATING  
COMMERCIAL SERIES  
COMMERCIAL 100 kW  
100  
ENGINE SIZE  
6.8 Liter V-10  
GENERATOR OUTPUT VOLTAGE/KW - 60Hz  
120/240V, single phase, 1.0 pf  
120/208V, 3-phase, 0.8 pf  
120/240V, 3-phase, 0.8 pf  
277/480V, 3-phase, 0.8 pf  
KW  
AMP  
CB Size  
100 LP / 98 NG  
100 LP / 98 NG  
100 LP / 98 NG  
100 LP / 98 NG  
416.6 LP / 408.3 NG  
347.4 LP / 340.4 NG  
301 LP / 295 NG  
150.5 LP / 147.5 NG  
450  
400  
350  
175  
GENERATOR LOCKED ROTOR KVA  
AVAILABLE @ VOLTAGE DIP OF 35%  
Single phase or 208V & 240V 3-phase  
480V 3-phase  
190  
225  
ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)  
Natural Gas  
(ft /hr.)  
130  
371  
713  
994  
1260  
Propane  
3
(gal/hr.)  
1.42  
4.06  
7.81  
10.88  
13.80  
cu ft/hr  
Exercise cycle  
52.3  
149.4  
287.4  
400.4  
507.8  
25% of rated load  
50% of rated load  
75% of rated load  
100% of rated load  
ENGINE COOLING  
Air flow (inlet air including alternator and combustion air)  
System coolant capacity  
Heat rejection to coolant  
Max. operating air temp. on radiator  
Max. ambient temperature  
3
ft /min  
5,500  
4.5  
342,000  
60 (150)  
50 (140)  
US gal.  
BTU/hr.  
°C (°F)  
°C (°F)  
COMBUSTION AIR REQUIREMENTS  
Flow at rated power 60 Hz  
cfm  
262  
SOUND EMISSIONS IN DBA  
db(A) @ 23 feet in exercise mode  
db(A) @ 23 feet at normal operating load  
61  
72  
EXHAUST  
Exhaust flow at rated output 60 Hz  
Exhaust temp. at muffler outlet  
cfm  
°F  
888  
960  
ENGINE PARAMETERS  
Rated synchronous RPM  
HP at rated KW  
60 Hz  
60 Hz  
2300  
168  
POWER ADJUSTMENT FOR AMBIENT CONDITIONS  
Temperature Deration  
3% for every 10 °C above - °C  
1.65% for every 10 °F above - °F  
25  
77  
Altitude Deration  
1% for every 100 m above - m  
3% for every 1000 ft. above - ft.  
183  
600  
RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility  
source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and  
specifications are subject to change without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power  
and condition, etc.  
 
INTERCONNECTIONS  
COMMERCIAL 100 kW  
100  
100  
100  
100  
240 1 ø  
208 3ø  
240 3ø  
480 3ø  
450  
400  
350  
175  
3-2/0 to 400 mcm  
2-3/0 to 500 mcm  
2-3/0 to 500 mcm  
#6 to 350 mcm  
COMMERCIAL SERIES  
INSTALLATION LAYOUT  
NOTE:  
Door access  
from both sides  
UNIT WEIGHT: Steel 2705 lbs., Aluminum 2531 lbs.  
GENERAC® POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI 53190  
www.guardiangenerators.com  
Bulletin 0174700SBY / Printed in USA 06.07, 08.07  
 
© 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.  

Haier Flat Panel Television LE39F32800 User Manual
Haier Refrigerator HC27SF22RB User Manual
Hamilton Beach Gas Grill 25285 User Manual
Harbor Freight Tools Mobility Aid 93033 User Manual
Hasbro Games 32730 User Manual
Hotpoint Clothes Dryer TFA53 User Manual
HP Hewlett Packard Network Card 3C905B TX User Manual
HP Hewlett Packard Personal Computer xw8000 User Manual
Hubbell Stereo System 31350 User Manual
IKEA Crib AA 182191 2 User Manual