Dimensions and Installation Information (in inches)  
The Installation Space  
41"  
36" Models 12"  
42" Models 18"  
48" Models 20"  
* Shipping height.  
The refrigerator  
25-3/4"  
Case Width  
can be adjusted to  
fit into a cutout that  
is 83-1/2" min. to  
84-1/2” max. height.  
Note that the top  
case trim at the  
front is 1/2" higher  
and will overlap  
upper cabinetry or  
soffit. Use leveling  
legs and wheels  
*Finished Width  
*84" From  
Floor to  
Top Frame  
*83-1/2"  
at  
Rear  
6"  
Electrical  
Area  
84-1/2" max  
83-1/2" min  
Finished  
5"  
75" From Floor  
to Bottom  
of Electrical  
Area  
Opening  
24"  
for a maximum 1"  
height adjustment.  
42"  
27-3/4"  
including  
handle  
Frame to Frame  
5"  
5"  
Water Supply  
3-1/2"  
Product Clearances  
3-1/2"  
Water and electrical locations  
These refrigerators are equipped with a 2 position door stop.  
The factory set 130° door swing can be adjusted to 90° if  
clearance to adjacent cabinets or walls is restricted.  
The opening must be prepared with the electrical and water  
supply located as shown.  
130° Door Swing  
90° Door Swing  
The cutout depth must be 24".  
The refrigerator will project forward, slightly beyond  
adjacent cabinetry, depending on your installation.  
13"  
19"  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24" installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
28-5/8"  
Frameless cabinets:  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
4" Min.  
to Wall  
Allow minimum clearances for freezer door and fresh food  
door for a full 130° door swing and to allow for pan removal.  
4" minimum clearance is required when door swing is  
adjusted to 90°. If the 90° door stop position is used, pan  
access is maintained, but pan removal is restricted.  
Additional Specifications  
• A 115 volt 60Hz., 15 or 20 amp power supply is required.  
An individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded 3-  
prong electrical receptacle recessed into the back wall.  
Electrical must be located on rear wall as shown.  
Installation Information: Before installing, consult  
installation instructions packed with product, or online  
at Monogram.com, for current dimensional data.  
Note: GFI (ground fault interrupter) is not recommended.  
• Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing or  
GE SmartConnectkit between the cold water line and  
water connection location, long enough to extend to the  
front of the refrigerator. Installation of an easily accessible  
shut off valve in the water line is recommended.  
For answers to your Monogram,® GE Profileor  
GE® appliance questions, visit our website at  
ge.com or call GE Answer Center® service,  
800.626.2000.  
As an EnErgy StAr®  
partner, gE has determined  
that this product meets the  
Laboratories  
Listed by  
Underwriters  
EnErgy StAr guidelines  
for energy efficiency.  
Specification Created 3/08  
110186  
 

Fisher Price Baby Accessories P6033 User Manual
Fisher Price Crib Toy 71985 User Manual
Fisher Price Motorized Toy Car 78656 User Manual
Frymaster Fryer Cool Zone Electric Fryer User Manual
Fujitsu Battery Charger FJBC GP User Manual
Garmin Marine Instruments 190 01015 01 User Manual
GE Car Stereo System DBXR463GDCC WW GE User Manual
Gemini CD Player CDX 601 User Manual
GE Monogram Beverage Dispenser ZDWG240 User Manual
GE Washer WWA9850M User Manual