GE Convection Oven JTP35SM User Manual

JTP35SM  
GE® 30" Built-In Double Wall Oven  
Dimensions and Installation Information (in inches)  
KW Rating  
Cutout width  
28-1/2'' MIN.  
28-5/8'' MAX.  
6.9  
5.2  
240V  
208V  
5
C
L
Cutout depth  
23-1/2" MIN  
2 x 4 or  
equivalent  
runners  
Breaker Size  
Junction box  
location  
E
30 Amps  
30 Amps  
240V  
208V  
A
B
Conduit  
(72"  
Note: Cabinets installed adjacent to wall ovens  
must have an adhesion spec of at least a 194°F  
temperature rating. Electric wall ovens are  
not approved for installation with a plug  
and receptacle. They must be hard wired in  
accordance with installation instructions.  
Suitable oven cabinet bracing must  
support 275 lbs.  
long)  
47" to  
Suitable  
bracing  
to support  
runners  
bottom of  
21-5/8"  
over centerline  
of cabinet  
junction box  
Cutout height  
51-13/16" MIN.  
51-15/16" MAX.  
(must support 325 lbs.)  
D
A
Cabinet  
30"  
11/16"-3/4"  
1"  
n
21  
A – Overlap of oven over side of edges of cutout  
B – Overlap of oven at top and bottom of cutout  
Oven  
C – Overall depth*  
D – Overall height with trim  
Overall height without trim  
E –Overall width  
*Depth including door handle is approximately 26-6/10" min. to  
26-9/10" max.  
21" minimum  
Door Opening  
Allowance  
Door handle protrudes 3" from door face.  
Cabinets and drawers on adjacent 45° and 90°  
walls should be placed to avoid interference with  
the handle.  
B
23-1/2"  
53-3/8"  
52-7/8"  
29-3/4"  
Minimum cutout location  
12" from the floor.  
C
Cabinet  
width 30"  
Installation Information: Before installing,  
consult installation instructions packed with  
product for current dimensional data.  
MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.  
THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.  
For answers to your Monogram,® GE Profileor  
GE® appliance questions, visit our website at  
ge.com or call GE Answer Center® service,  
800.626.2000.  
All GE ranges are equipped with  
an Anti-Tip device. The installation  
of this device is an important,  
required step in the installation  
of the range.  
Listed by  
Underwriters  
Laboratories  
Specification Revised 9/07  
320146  
 

Eizo Computer Monitor EV2411W User Manual
Eizo Computer Monitor F520 User Manual
Elation Professional Work Light 72MKII User Manual
Escort Radar Detector 7500S User Manual
Ferris Industries Lawn Mower IS1500Z User Manual
Fisher Price Baby Toy T5772 User Manual
Fisher Price Table Top Game T3856 User Manual
Fisher Price Video Game Console R9701 User Manual
Frigidaire Microwave Oven FFMV162LB User Manual
Goodman Mfg Air Conditioner SS PGBC50 User Manual