Broan Ventilation Hood 356NDK User Manual

EXTERIOR & IN-LINE BLOWER MOUNTING PLATE  
READ AND SAVE THESE INSTRUCTIONS  
WARNING  
CAUTION  
TO REDUCE THE RISK OF FIRE, ELECTRICAL 1. For general ventilating use only. Do not use to  
SHOCK, OR INJURY TO PERSONS, OBSERVE  
THE FOLLOWING:  
exhaust hazardous or explosive material and  
vapors.  
1. Use this unit only in the manner intended by the 2. Toavoidmotorbearingdamageandnoisyand/or  
manufacturer. If you have questions, contact the  
manufacturer at the address or telephone num-  
ber listed in the warranty.  
unbalanced impellers, keep drywall spray, con-  
struction dust, etc. off power unit.  
3. Your hood motor has a thermal overload which  
will automatically shut off the motor if it becomes  
overheated. The motor will restart when it cools  
down. If the motor continues to shut off and  
restart, have the hood serviced.  
2. Beforeservicingorcleaningunit,switchpoweroff  
at service panel and lock service panel to prevent  
powerfrombeingswitchedonaccidentally.When  
the service disconnecting means cannot be  
locked, securely fasten a prominent warning de-  
vice, such as a tag, to the service panel.  
4. Please read specification label on product for  
further information and requirements.  
3. Installation work and electrical wiring must be  
done by a qualified person(s) in accordance with  
allapplicablecodesandstandards,includingfire-  
rated construction codes and standards.  
10" ROUND ELBOW  
10" ROUND DUCT  
4. Sufficientairisneededforpropercombustionand  
exhaustingofgasesthroughtheflue(chimney)of  
fuel burning equipment to prevent backdrafting.  
Follow the heating equipment manufacturer's  
guideline and safety standards such as those  
published by the National Fire Protection Asso-  
ciation (NFPA), and the American Society for  
Heating, RefrigerationandAirConditioningEngi-  
neers (ASHRAE), and the local code authorities.  
5. When cutting or drilling into wall, or ceiling, do not  
damage electrical wiring or other hidden utilities.  
6. Ducted fans must always be vented to the out-  
doors.  
SOFFIT  
3
EXTERIOR  
BLOWER  
WALL HOOD  
CANOPY  
(island canopy  
available)  
ROUGH-IN  
PLATE  
18"  
12" MIN.  
ABOVE ANY  
OBSTRUCTION  
24" or 27"  
DUCT OPENING  
COVER PLATE  
TYPICAL WALL MOUNTED INSTALLATION  
(Vertical discharge - elbow to horizontal)  
7. To reduce risk of fire, use only metal ductwork.  
8. This unit must be grounded.  
EXTERIOR BLOWER  
10" ROUND DUCT  
10" ROUND  
DUCT  
SOFFIT  
DUCT  
WALL HOOD  
OPENING  
CANOPY  
COVER  
(island canopy  
PLATE  
SOFFIT  
available)  
EXTERIOR  
BLOWER  
WALL HOOD  
CANOPY  
(island canopy  
available)  
18"  
DUCT  
OPENING  
COVER PLATE  
24" or 27"  
ROUGH-IN  
PLATE  
18"  
ROUGH-IN  
PLATE  
12" MIN.  
ABOVE ANY  
OBSTRUCTION  
24" or 27"  
TYPICAL ROOF MOUNTED INSTALLATION  
(Vertical discharge)  
TYPICAL WALL MOUNTED INSTALLATION  
(Horizontal discharge)  
NOTE: Horizontal discharge requires relocation of the duct opening cover plate. See hood manual  
for instructions.  
 

Black Box Computer Drive USB 20 to SATA Enclosure User Manual
Black Decker Fan BDHT5016 User Manual
Bolens Lawn Mower 111 112A User Manual
Canon Camera Accessories 2750B002 User Manual
Canon Scanner CD 4070NW User Manual
Carrier Marine Heating System 25HPA6 User Manual
Casio Cash Register pcr 360 User Manual
CDA Electric Pressure Cooker RV 700 User Manual
Celestron Telescope 21051 W User Manual
Chamberlain Garage Door Opener 2580C 1 2 HP User Manual