VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 12
VEC027BD
TW O YEAR LIMITED WARRAN TY PRO GRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the
responsibilities of Vector Manufacturing, regarding this product. There is no other warranty, other than
those described herein. Any implied warranty of merchantability or fitness for a particular purpose on
this product is limited in duration to the duration of this warranty.
This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in
materials and workmanship for two years from the date of purchase without additional charge. The
warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for
any amount of damage in excess of the retail purchase price of the product under any circumstances.
Incidental and consequential damages are specifically excluded from coverage under this warranty.
Ele ctro m a te ™ Plu s 3 0 0
AC/ DC Po rta b le Po w e r Su p p ly
Ju m p -Sta rte r/ In fla to r
This product is not intended for commercial use. This warranty does not apply to damage to units from
misuse or incorrect installation/ connection. Misuse includes wiring or connecting to improper polarity
power sources.
Co rd le ss • Re ch a rg e a b le
RETURN/ REPAIR POLICY: Defective products may be returned to manufacturer. Any defective product
that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge.
If such a product is returned more than 30 days but less than two years from the purchase date,
manufacturer will repair the unit or, at its option, replace it, free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option.
A unit may be replaced with a new or reconditioned unit of the same or comparable design. The
repaired or replaced unit will then be warranted under the terms of the remainder of the warranty
period. The customer is responsible for the shipping charges on all returned items. During the warranty
period, manufacturer will be responsible for the return shipping charges to the customer in the United
States.
LIMITATIONS: This warranty does not cover accessories, such as charging adapters, bulbs, fuses and
batteries, damage or defects resulting from normal wear and tear (including chips, scratches, abrasions,
discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our
service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow
instructions for care and maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department toll free at (800)
618-5178 for general repair information and charges if applicable. You may also contact us through
our website at www.vectormfg.com.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser
specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax
or mail (see below). We suggest that you keep the original packaging in case you need to ship the unit.
When returning a product, include your name, address, phone number, dated sales receipt (or copy)
and a description of the reason for return and product serial number. After repairing or replacing the
unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector
Manufacturing. Enter “VEC027BD” as Model and “Electromate™ Plus 300” as Product Type. All Vector
products must be registered within 30 days of purchase to activate this warranty. Mail the completed
registration form, along with a copy of the original sales receipt, to:
USER’S MAN UAL
& WARRAN TY IN FO RMATIO N
ATTN.: CUSTOMER SERVICE
4140 SW 30th Ave., Ft. Lauderdale, FL 33312
• TOLL FREE: (800) 618-5178 • FAX: (954) 584-5556 •
IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIO NAL MANUAL. THIS MANUAL CO NTAINS IMPO RTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
WARRANTY IS NON-TRANSFERABLE.
BD122805
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312 U.S.
Toll Free: (800) 618-5178
© 2006 VECTOR MANUFACTURING
MADE IN CHINA
w w w .ve cto rm fg .co m
12
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page iv
TABLE O F CO N TEN TS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC and DC Charging/ Recharging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viewing Battery Charge Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
120 Volt AC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Volt DC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Electromate Plus as a Jump-Starter . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Alternator Check Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the 12 Volt Portable Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the 120 Volt AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Emergency Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Tire Inflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inflating Products With a Valve Stem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inflating Products Without a Valve Stem . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Replacement/ Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuse Replacement (DC Accessory Adapter) . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
3
3
3
3
4
5
5
6
7
7
7
8
9
9
9
9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
IN TRO DUCTIO N
Thank you for purchasing the Bla ck & De ck e r VEC0 2 7 BD Ele ctro m a te ™ Plu s
3 0 0 . Please read this guide carefully before use to ensure optimum performance
and avoid damage to the unit.
FEATURES
• Powers 110/ 120 volt AC appliances
• Powers 12 volt DC appliances
• Jump-starts vehicle engines
• Built-in inflator
• Built-in 300 watt inverter
• Includes non-spillable, maintenance-free, heavy-duty, sealed battery
• Safe to use, transport and store
• Alternator check
• Reverse polarity connection warning
• Detachable jumper cables
• Requires no maintenance (other than recharging) for optimum operation
• Rechargeable with built-in AC charger
• Unique compact design provides completely portable 12 volt DC power
• Molded high-impact case is tough and durable
• Built-in area light for night time roadside repairs and use in remote locations
without utility power
• Battery charge level indicators
1
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 2
Pro te ctive Fe a tu re s
AC AN D DC CHARGIN G/ RECHARGIN G
• Auto m a tic O ve rlo a d — Built-in protection against overload — in the event the
AC outlet draws more than 300 watts, power to the unit’s outlet will automatically
shut off.
Use a common household AC extension cord for charging (cord not supplied).
For maximum battery life, we recommend the unit be kept fully charged at all times.
If the battery is allowed to remain in a discharged state, battery life will be shortened.
• Gro un d Fa ult Circuit In te rrup te r (GFCI) — The GFCI protects the unit and the
user by sensing imbalances in a circuit caused by current leakage to the ground
and shuts down the unit’s AC outlet to prevent electrical shock.
• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING.
• Charge the unit for a full 24 hours using AC method before first use.
• Recharge the unit fully after each use.
• O ve rh e a tin g — Unit automatically shuts down if it exceeds a safe temperature.
• Recharge the unit every two months when it has not been used regularly.
• Sa fe ty Po w e r Sw itch a n d Re ve rse Po la rity Ala rm — In event the
cables/ clamps are reversed during jump-starting, an indicator lights and an alarm
sounds BEFORE the Power Switch is turned ON.
N o te s: Re ch a rg in g th e b a tte ry a fte r e a ch u se p ro lo n g s b a tte ry life ; fre q u e n t
d isch a rg e s b e tw e e n re ch a rg e s re d u ce s b a tte ry life .
Th e Ele ctro m a te Plus a lso co m e s w ith a DC/ DC ch a rg in g a d a p te r fo r re ch a rg in g
th e un it fro m a 1 2 vo lt DC a cce sso ry o utle t in a ve h icle .
• Lo w Ba tte ry — If the battery power level is too low, the AC Power Supply shuts
If u n it is fu lly d isch a rg e d , it is re co m m e n d e d th a t th e ve h icle b e in g u se d fo r
re ch a rg in g b e le ft ru n n in g w h ile th e u n it is ch a rg e d via th e 1 2 vo lt DC m e th o d .
down automatically.
Fro n t Vie w
Ba ck Vie w
UN IT FRO N T PAN EL
RUBBER HAN DLE
Vie w in g Ba tte ry Ch a rg e Sta tu s
AC CHARGER
JUMPER CABLE
CO N N ECTO R
Press the Battery Charge Level pushbutton to display battery status. The Battery
Charge Level Indicator LEDS will light.
AIR VEN TS
LEDS (fro m le ft to rig h t):
• Red LED indicates a low battery charge
• Two Red LEDs indicate a medium level or partially charged battery
• Two Red and one Green LED indicates a full or high level battery charge.
1 2 0 Vo lt AC Ch a rg in g
DC PO W ER SUPPLY
PAN EL
1. Lift the AC adapter cover located on the back of the Ele ctro m a te Plus and
connect an extension cord to the unit. Plug the other end of the cord into a
standard 120 volt AC wall outlet.
AC PO W ER SUPPLY
PAN EL
IN FLATO R
1 2 VO LT DC ADAPTER STO RAGE
CO MPARTMEN T
2. Charge until two Red and one Green LEDs light.
Fro n t Pa n e l
3. Once fully charged, disconnect the extension cord.
BATTERY CHARGE
LEVEL IN DICATO RS
BATTERY CHARGE LEVEL
PUSHBUTTO N
N o te : Th e u n it ca n n o t b e o ve rch a rg e d u sin g th e AC m e th o d .
1 2 Vo lt DC Ch a rg in g
JUMP-START SAFETY
O N / O FF SW ITCH
ALTERN ATO R CHECK
IN DICATO R
The DC recharging method will NOT recharge the unit as effectively as recharging
from 120 volt AC. The 12 volt DC recharging procedure is recommended only when
it is necessary, since frequent use of the 12 volt DC recharging procedure may
shorten the battery system’s life.
REVERSE PO LARITY
IN DICATO R
IN FLATO R PRESSURE
GAUGE
1. Insert the gold-tipped DC/ DC charging adapter plug into the vehicle’s 12 volt DC
accessory outlet.
IN FLATO R
O N / O FF SW ITCH
2. Insert the silver-tipped end plug into the 12 volt DC accessory outlet on the front
panel of the unit.
AREA LIGHT
O N / O FF SW ITCH
3. To check the charge status of the battery during DC charging, disconnect the DC
adapter from the accessory outlet and push the Battery Charge Level pushbutton.
Observe the battery charge indicator.
AREA LIGHT
Air In fla to r No zzle s
4. When charging is complete, remove the power cord and return it to the storage
compartment.
2
3
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 4
5a. Connect NEGATIVE (–) BLACK clamp to vehicle battery’s NEGATIVE
ungrounded post.
WARN IN G
Do n o t re ch a rg e fo r m o re th a n 5 to 6 h o urs m a x im um usin g th e 1 2
vo lt DC m e th o d .
5b. Connect POSITIVE (+) RED clamp to the vehicle chassis or engine block
away from the battery. Do not connect the clip to carburetor, fuel lines or
sheet-metal body parts. Connect to a heavy gauge metal part of the frame
or engine block.
USIN G THE ELECTRO MATE PLUS AS A JUMP-STARTER
WARN IN G
Be fo re u sin g th is sy ste m to ju m p -sta rt a n y ve h icle re a d a n d
un d e rsta n d a ll in structio n s, sa fe ty tip s, w a rn in g s, ca utio n s a n d first
a id in fo rm a tio n p ro vid e d in th is m a n ua l a n d o n th e p ro d uct la b e lin g .
Ad d itio n a l im p o rta n t in fo rm a tio n m a y a lso b e p ro vid e d b y th e
ve h icle ’s b a tte ry syste m m a n ufa cture r.
DO NO T TURN SAFETY SW ITCH O N IF REVERSE PO LARITY ALARM
SO UNDS O R THE REVERSE PO LARITY INDICATO R LIGHTS. REVERSE
THE CLAMP CO NNECTIO NS.
6. After making proper connections, turn safety power switch to ON.
7. Start vehicle (do not turn key for longer than 5-6 seconds).
8. After vehicle starts, turn the safety power switch to off, remove clamps (disconnect
the frame or engine clamp first, followed by the battery cable). Disconnect the
cables from unit.
CAUTIO N
To a vo id p o ssib le d a m a g e th a t m a y sh o rte n th e un it’s w o rk in g life ,
p ro te ct th is un it fro m d ire ct sun lig h t, d ire ct h e a t a n d m o isture .
N o te s: Alw a y s d isco n n e ct th e e n g in e o r fra m e ju m p e r cla m p first; fo llo w e d b y
th e b a tte ry ju m p e r cla m p .
Th is syste m is to b e use d O NLY o n ve h icle s, g a rd e n tra cto rs a n d
g a so lin e -p o w e re d g e n e ra to rs w ith 1 2 vo lt DC b a tte ry syste m s.
If e n g in e fa ils to sta rt, le a ve th e ig n itio n tu rn e d o ff a n d d isco n n e ct th e
N EGATIVE (–) cla m p first, th e n th e PO SITIVE (+) cla m p . Try a g a in la te r —
th e e n g in e m a y b e flo o d e d .
Th is syste m is NO T d e sig n e d to b e in sta lle d a s a re p la ce m e n t fo r a
ve h icle b a tte ry.
Re ch a rg e th e Ele ctro m a te Plu s a fte r e a ch u se .
WARN IN G
USIN G THE ALTERN ATO R CHECK FEATURE
Co n n e ct o r d isco n n e ct b a tte ry le a d s O NLY w h e n AC o r DC ch a rg in g
sup p ly co rd is d isco n n e cte d .
1. Turn the safety switch to the OFF position.
2. Connect jumper cables to unit.
Ju m p -Sta rtin g In stru ctio n s
3. Connect to vehicle.
This jump-starter is equipped with a manual safety switch that only allows jump-start
energy to flow when proper connections are made to battery and frame.
4. Start engine.
5. Turn vehicle accessories off.
Connect — RED clamp first, then BLACK clamp. Disconnect — BLACK clamp first,
then RED clamp.
6. A green LED indicates a good alternator. A red LED indicates a bad alternator.
1. Turn OFF vehicle ignition and all accessories (radio, A/ C, lights, cell phone, etc.).
Place vehicle in “park” and set the emergency brake.
USIN G THE 1 2 VO LT DC PO RTABLE PO W ER SUPPLY
1. Flip open one of the 12 volt DC outlet covers on the DC Power Supply Panel.
2. Insert the 12 volt DC plug from the appliance into the outlet.
3. Turn on the appliance and operate normally.
2. Make sure jump-start system’s ON/ OFF power switch is turned to OFF.
3. Connect jumper cables to unit.
4. To jump-start a NEGATIVE GROUNDED SYSTEM (NEGATIVE battery terminal
is connected to the chassis — the most common configuration), follow steps 4a
and 4b, then proceed to step 6.
DC Po w e r Sup p ly Pa n e l
1 2 VO LT DC O UTLETS
4a. Connect the POSITIVE (+) RED clamp to vehicle battery’s POSITIVE
ungrounded post.
4b. Connect the NEGATIVE (–) BLACK clamp to the vehicle chassis or engine
block away from the battery. Do not connect the clip to carburetor, fuel lines
or sheet-metal body parts. Connect to a heavy gauge metal part of the frame
or engine block.
AIR VEN TS
5. To jump-start a POSITIVE GROUNDED SYSTEM — In the rare event that the
vehicle to be started has a POSITIVE Grounded System, POSITIVE battery
terminal is connected to chassis, replace steps 4a and 4b above with steps 5a
and 5b, then proceed to step 6.
CAUTIO N
DO NO T USE UNIT TO PO W ER APPLIANCES THAT DRAW MO RE THAN
5 AMPS DC.
4
5
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 6
USIN G THE 1 2 0 VO LT AC PO W ER SUPPLY
USIN G THE EMERGEN CY AREA LIGHT
The 120 Volt AC Power Supply is designed for maintaining today's modern lifestyle
while traveling in vans, RVs, automobiles, trucks, or vehicles that have a 12 volt DC
battery power supply and a means to recharge those batteries. The Ele ctro m a te ™
Plus 3 0 0 comes with:
The Area Light is controlled by an ON/ OFF pushbutton. Make sure the light is turned
OFF when the unit is being recharged or stored.
USIN G THE TIRE IN FLATO R
1. AC ON/ OFF Switch — Slide switch to turn the AC Power Supply ON and OFF.
2. 120 Volt AC Power Outlets
Re a d In structio n s Ca re fully to Avo id Po ssib le In jury o r Pro p e rty
Da m a g e .
3. AC Power Supply “ON” Status Indicator — green LED lights when AC outlet is
turned on; green LED flashes on and off when faulted.
The built-in 12 volt DC inflator is the ultimate inflator for all vehicle tires, trailer tires
and recreational inflatables. Three different sized nozzles are supplied. Each nozzle
clips on the end of the standard tire valve connector attached to the free end of the
inflator hose. The inflator hose with tire fitting is stored in a retaining channel between
the jumper cable channels on the rear of the unit. The ON/ OFF switch is located on
the front of the unit. The inflator can operate long enough to fill up to 3 average sized
tires before the battery must be recharged. The inflator may be used by removing the
air hose from the storage hatch and, if required, fitting the appropriate nozzle to the
air hose. Return the hose to the storage compartment after use.
4. AC Power Ground Fault Circuit Interrupt (GFCI) — a 3-prong outlet for 120 volt
AC appliances which shuts down inverter if leakage or ground fault current is
detected.
5. Internal protective circuits including:
•
Overload and over-temperature shutdown (activated if AC output exceeds 300
watts)
•
•
•
AC short-circuit shutdown
Low voltage shutdown
A new cooling technology that more efficiently cools the power transistors and,
combined with soft start, dramatically increases reliability and product life
N o te : Th e rm o -p ro te ctio n d e vice sh u ts d o w n th e u n it w h e n th e u n it o ve rh e a ts a n d
re sta rts o n ce th e u n it h a s re a ch e d a sa fe o p e ra tin g te m p e ra tu re .
WARN IN G
Th e in fla to r is ca p a b le o f in fla tin g up to 1 2 0 p o un d s p e r sq ua re in ch
(p si) p re ssure . To a vo id o ve r in fla tin g , ca re fully fo llo w in structio n s o n
a rticle s to b e in fla te d . Ne ve r e x ce e d re co m m e n d e d p re ssure s. Alw a ys
ch e ck p re ssure w ith th e p re ssure g a ug e . Ne ve r le a ve th e in fla to r
un a tte n d e d w h ile in use . Burstin g a rticle s ca n ca use se rio us in jury.
AC Po w e r Su p p ly Co n tro ls a n d In d ica to rs
The illustration below details the AC Power Supply front panel. Air vents keep the unit
from overheating. An ON/ OFF switch turns the AC power circuitry on and off. The
ON/ OFF switch can also be used to reset the AC power after shutdown due to
overvoltage, overload or over-temperature condition. The “ON” status indicator lights
when the AC power supply is on. The AC outlets (covered when not in use) supply
power to AC appliances.
CAUTIO N
Do not op era te infla tor continuously for ex tend ed p eriod s of tim e
(a p p rox . 1 5 m inutes, d ep end ing on the a m b ient tem p era ture), a s it
m a y overhea t. In such event, infla tor w ill shut d ow n a nd resta rt a fter a
cooling p eriod of a p p rox im a tely 1 5 m inutes.
AC Po w e r Sup p ly Fro n t Pa n e l
AC PO W ER SUPPLY
“ O N ” STATUS
IN DICATO R
AC PO W ER SUPPLY
O N / O FF SW ITCH
In fla tin g Pro d u cts W ith a Va lve Ste m
1. Place standard connector (chuck) on valve stem.
1 2 0 VO LT AC
O UTLETS
2. Push connector toward valve stem and close thumb latch.
AIR VEN TS
N o te : Ma k e su re co n n e cto r is p u sh e d o n to va lve ste m a s fa r a s p o ssib le
b e fo re clo sin g th u m b la tch .
3. Slide inflator switch to ON.
AC Po w e r Su p p ly O p e ra tio n
4. Check pressure with the pressure gauge.
5. When desired pressure is reached, slide the inflator switch to OFF; open thumb
latch and remove connector from valve stem.
1. Turn power switch to ON (the power indicator lights).
2. Plug in appliance and turn the appliance on.
N o te : Th e AC p o w e r su p p ly sh u ts d o w n a u to m a tica lly w h e n th e b a tte ry vo lta g e le ve l
is to o lo w . If th e g re e n LED fla sh e s, a fa u lty co n d itio n su ch a s a n o ve rlo a d ,
o ve rh e a tin g o r sh o rt circu itin g h a s o ccu rre d . Tu rn th e AC Po w e r Su p p ly O FF a n d
u n p lu g th e a p p lia n ce . Wa it a fe w m in u te s, th e n tu rn p o w e r b a ck O N .
6. Store inflator hose and tire fitting in storage compartment.
6
7
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 8
In fla tin g Pro d u cts W ith o u t a Va lve Ste m
CARE AN D MAIN TEN AN CE
CAUTIO N
If th e co rd , w ire s, o r ca b le s b e co m e d a m a g e d , re tu rn th e e n tire u n it
to Ve cto r Ma n u fa ctu rin g im m e d ia te ly fo r se rvice / re p a ir.
Inflation of other items requires use of one of the adapters (nozzles).
1. Insert appropriate adapter (e.g. needle) into connector (chuck) and close thumb
latch.
2. Insert adapter (e.g. needle) into item to inflate.
3. Slide inflator switch to ON.
Re p la ce m e n t Pa rts
For replacement parts (bulbs, batteries, fuses, etc.), contact Customer Service, toll-
free, at (800) 618-5178.
4. Refer to the following table for approximate filling pressure and time. Small items
such as volleyballs, footballs, etc. inflate very rapidly.
Ba tte ry Re p la ce m e n t/ Disp o sa l
5. Slide inflator switch to OFF.
It is recommended that the unit be returned to Customer Service
for battery replacement.
6. Remove adapter from item and store properly.
Typ ica l In fla tio n Tim e s
This unit contains a maintenance-free, non-spillable, sealed lead-
acid battery. This battery is fully recyclable and should be
accepted at any location that accepts common automotive
starter batteries. Examples of places that accept these batteries
are: county or municipal recycling drop-off centers, scrap metal
dealers and retailers who sell automotive replacement lead acid
starter batteries.
In fla tio n p re ssure (p si)
Ap p ro x . Fillin g tim e
Vehicle and trailer tires
155/ 80R 13"
185/ 70R 14"
235/ 75R 16"
235/ 70R 17"
26
30
30
42
2.5 min.
4.5 min.
6.5 min.
16 min.
Bicycle tires
27" X 1" (racing)
WARN IN GS
90
40 sec.
Do n o t d isp o se o f th e b a tte ry in fire , a s th is m a y re sult in a n e x p lo sio n .
Football
Basketball
Volleyball
13
10
5
24 sec.
20 sec.
6 sec.
Be fo re d isp o sin g o f th e b a tte ry, p ro te ct e x p o se d te rm in a ls w ith
h e a vy-d u ty e le ctrica l ta p e to p re ve n t sh o rtin g (sh o rtin g ca n re su lt in
in ju ry o r fire ).
WARN IN G
Do n o t e x p o se b a tte ry to fire o r in te n se h e a t, a s it m a y e x p lo d e .
Alw a ys fo llo w tire m a n ufa cture r’s re co m m e n d a tio n s fo r p re ssure o n
ite m to b e in fla te d .
Fu se Re p la ce m e n t (DC Acce sso ry Ad a p te r)
1. Remove plug from accessory outlet. Remove the gold cap by turning counter-
clockwise and lifting off.
2. Remove center pin and spring. Remove fuse.
3. Replace fuse with same type and size fuse (8 amp).
4. Replace center pin and spring inside plug.
5. Replace gold cap by turning clockwise.
8
9
VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 10
SPECIFICATIO N S
1 2 Vo lt DC Sp e cifica tio n s
Battery:
12 volt DC rechargeable, maintenance-free
Sealed, AGM lead-acid
Internal Battery Type:
Internal Battery
Capacity:
12 volt 19Ah/ 20 hour rate
Area Light :
Light Emitting Diode (LED)
Jumper Cables:
Heavy duty welding cable with 450 amp clamps
Accessory Outlet
Protection:
5 amp, dual self-resetting breakers
DC Charging Adapter: 12 volt DC
AC Po w e r Sp e cifica tio n s
Output Power:
Continuous — 300 watts
Output Voltage:
120 VAC RMS
60 Hz ±4 Hz
Modified sine wave
Yes
Output Frequency:
Output Waveform:
Overheat Protection:
Overload Protection:
Yes
Output Short Circuit
Protection:
Yes
Tire In fla to r Sp e cifica tio n s
Maximum Pressure: 120 PSI
Ba tte ry Ch a rg e r Sp e cifica tio n s
Input:
120 volt AC, 60 Hz
Rapid Charging
Current:
12 volt DC 1000mA
10
11
|