Belkin Power Supply F6H350 USB User Manual

ALARMS  
Back Up (Slow Alarm)  
INSTALLATION  
When in “BACK UP” on battery mode, the RED LED illuminates and the  
UPS sounds an audible alarm. The alarm stops when the UPS returns to  
LINE NORMAL operation.  
Note!  
Before installation, please inspect the UPS Upon  
receipt. Make sure that everything inside the package  
is not damaged.  
Low Battery (Rapid Alarm)  
R
In “BACK UP” mode, when the battery energy runs low, the UPS beeps  
rapidly until the UPS shuts from a depleted battery or returns to LINE  
NORMAL operation.  
Connect to AC Utility Power  
Connect the AC inlet to utility power via the power  
cord. Please make sure there are no devices  
plugged into the UPS unit. Check to see if the “Site  
Wiring Fault” indicator is lit or not. If it is lit, please  
have the utility wiring inspected by an electrician.  
F6H350-USB  
F6H500-USB  
F6H650-USB  
Fault (10 Seconds Continuously)  
When the output is shorted, the UPS emits a 10 seconds continuously  
alarm to warn of a short condition. Disconnect the equipment prior to  
checking the equipment.  
Charging the Battery  
FRONT PANEL  
For best results, charge the battery for 6 hours prior  
to initial use. The UPS charges its battery whenever  
it is connected to the utility power. Should you see  
the red battery light come on, the battery may need  
immediate charging.  
2
Battery Light  
Turning on the UPS  
Turn on your UPS by depressing the On/Off button for  
approximately 2 seconds. You will see the green indicator light come  
on.  
INTRODUCTION  
Thank you for purchasing a Belkin Uninterruptible Power Supply  
(UPS). Each year, several natural and man made occurrences put  
the power supplied to your electronics in your home or office in  
jeopardy. At risk are your hardware, software and data because of  
these power problems.  
3
Plug in Power Devices  
Plug your devices into the AC outlets on the top of the UPS. To use  
the UPS as a master on/off switch, make sure all of the loads are  
switched on.  
Caution: Never connect a laser printer or  
scanner to the backup outlets of UPS with  
other computer equipment. A laser printer or  
scanner draws significantly more power  
when in use than when idles. This may  
IMPORTANT SAFETY INSTRUCTIONS  
Please save this manual!  
It contains important operating instructions and warranty information  
pertaining to your UPS.  
1
Diagram 1  
Please save or recycle the packaging materials!  
1. UPS Outlets (See #1 on Diagram 1)  
overload the UPS.  
The UPS packaging was designed with great care to provide  
protection during shipment and delivery. These materials are  
invaluable if you ever have to return the UPS for service. Damage  
sustained during transit is not covered under the warranty.  
These outlets are your battery back up outlets. We strongly  
recommend that only sensitive equipment such as your computer and  
monitor should be plugged into these outlets. Caution: Never  
connect a laser printer or scanner to the backup outlets of UPS  
with other computer equipment. A laser printer or scanner  
draws significantly more power when in use than when sitting  
idle. This may overload the UPS.  
Laser Printer  
Connect the phone/ fax/ modem lines  
Connect a single phone / fax/ modem line into the surge protected  
sockets on the right of the UPS. The RJ-11 modular sockets accept  
standard single line telephone connections.  
Federal Communications Commission Interference Statement  
This equipment has been tested and found to comply with the limits  
for a Class B digital device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against  
harmful interference in a residential installation. This equipment  
generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause  
harmful interference to radio communications. To assure continued  
compliance, use only shielded interface cables when connecting to  
computer or peripheral devices. Any changes or modifications not  
expressly approved by the party responsible for compliance could  
void the user’s authority to operate this equipment.  
Plug one end of the phone cable you received into your telephone  
wall jack and plug the other end into the jack marked IN. You may  
now plug a phone, fax or modem into the two jacks marked OUT.  
(See Diagram 4)  
Should a power outage occur, your battery backup would  
automatically turn on. Power (utility or battery) is not supplied to these  
outlets when the UPS is switched off.  
Do not plug any surge protectors or power strips into the battery  
back-up outlets (i.e. daisy chaining).  
Phone  
2. SURGE Protected outlets (See #2 on Diagram 1)  
These outlets do not provide power during a power outage.  
Equipment such as computer peripherals, printers, fax machine’s, or  
a desk lamp may be plugged into these outlets. The On/Off button  
does not control these outlets.  
CONTENTS  
You should have received the following:  
1 – UPS unit  
1 – Sentry Bulldog Shutdown Software  
1 – USB Cable  
Modem  
/ Fax  
3. The On/Off button has 3 functions:  
1. Turns on the UPS. Depress button at least 2  
seconds. The green light will come on.  
To Telephone Socket  
Diagram 4  
2. Cold Start function. Assuming the battery is  
charged the UPS will work without it being  
plugged into an outlet. Depress and hold the key  
for at least 2 seconds to turn on the UPS. The  
1 – Phone Line Cable  
Note: This connection is optional but highly suggested as phone /  
fax / modem lines often carry dangerous surges and spikes. The  
UPS works properly without a phone / fax/ modem connection.  
Caution: The phone/fax/modem protection feature could be  
rendered inoperable if improperly installed. Make sure that the  
telephone line from the wall is plugged into the connector marked  
“IN”, and the devices to be protected (phone/ fax/ modem) are plugged  
into the connector marked “ OUT”.  
UPS FEATURES AND FUNCTIONS  
Before installation, please inspect the UPS upon receipt. Make sure  
that nothing is damaged.  
Battery Light  
3. Silence function. During “On Battery Mode”, the  
audible sound can be turned “ON” or “OFF” by  
depressing the switch.  
Your UPS features 3 LED indicators. Each is marked by a power  
icon; please familiarize yourself with this chart, as it will assist you in  
the use of your UPS.  
USB (Universal Serial Bus) Communication Port  
A USB port is provided to relay the signal to support DOS,  
WINDOWS, and the other operating system.  
Side Panel A  
Indicator  
Condition  
Description  
1
AC Input  
Circuit Breaker  
Push to Reset  
OUT  
OUT  
IN  
AC power is on  
- Solid green  
Phone/Fax  
Modem  
Protection  
3
ON-LINE  
Refer to Bottom for  
Cautionary Markings  
2
Communication port  
This condition for the  
On-Battery and  
Low-Battery LED can  
indicate 1 of 3 problems:  
(Optional) To fully utilize the Sentry Bulldog Shutdown Software; you  
will need to connect the UPS to your computer. Connect the USB  
cable to your UPS then connect the other end to the USB port on  
your computer.  
Diagram 2  
4. AC Input Power Cord (See #1 on Diagram 2)  
Provides power to your UPS.  
1. The UPS is on battery  
backup and an  
intermittent audible  
alarm is on. The UPS  
will begin shutdown  
procedure.  
5. Phone/ Fax/ Modem Surge Protection (See #2 on Diagram 2)  
The Phone/ Fax/Modem lines are surge protected. There is one input  
jack and two output jacks. This allows you to split one telephone  
connection to two separate devices.  
Software Installation (Optional)  
Compatible with any computer running the following:  
95/98/ME/NT4/2000/XP & Novell 3.X & Higher  
- Flashing Red  
LED with Audible  
Alarm (Beeping)  
ON-BATTERY  
and  
LOW-BATTERY  
2. Battery is low. The UPS  
will start shutdown. The  
buzzer sounds an  
1. Your UPS features the Sentry Bulldog Shutdown Software.  
This allows you to protect and save your data should a power  
outage occur, as well as safely shutdown your computer in your  
absence. This software is compatible with Windows  
6. AC Breaker (Circuit Breaker; See #3 on Diagram 2)  
Should a power overload occur, the circuit breaker would trigger the  
UPS to turn off AC power. In order to restore the power, depress the  
circuit breaker button to reset, then depress the Power button.  
audible alarm.  
95/98/ME/NT4/2000/XP and Novell 3.X & higher.  
3. There is a problem with  
the UPS. The LED will  
be lit continuously and  
the buzzer will sound  
audible alarm for 10  
sec.  
Side Panel B  
2. To install the software, please place the CD into the CD drive of  
your computer.  
3. Your computer should automatically run (AutoPlay) the CD. If  
this does not occur, go to the Run feature on your Start icon  
(lower left corner) on your screen. Please enter the CD drive, it  
may be D: Should you continue to have a problem, please refer  
to your computer’s owner’s manual for the correct drive. Upon  
entering the drive Run setup.exe. to execute the software.  
The Site Wiring fault LED  
can indicate 1 of 2 possible  
conditions:  
1. Open or high resistance  
on the ground line  
2. Hot or neutral polarity  
circuit  
USB Communication Port  
4. Once uploaded, please click the Bulldog icon on the screen.  
SITE WIRING  
FAULT  
Diagram 3  
5. Click Install Belkin Sentry Bulldog for Win  
95/98/ME/NT4/2000/XP  
- Solid Red  
*Note in order for your UPS  
to work properly, you must  
have a properly grounded  
AC circuit. If your Site  
Wiring Fault LED is lit,  
please contact an  
7. Your UPS features a USB communication port. Installation of the  
cable and software is optional. This allows the UPS to connect to you  
computer. The Sentry Bulldog Software will not work if the UPS is not  
connected to you computer. This does not mean the battery backup  
feature will not work without the software and cable installed. The  
UPS will still provide backup power but you will be unable to utilize  
the data management capabilities of the software.  
6. InstallShield Wizard will appear onscreen, click Next.  
7. Please read the License Agreement and click Yes.  
electrician to properly wire  
this circuit.  
8. On Setup Type, click ALL (Standalone). You should not install  
the networking files unless you are technically qualified to use  
these features. For more information on networking, please  
refer to the software user’s manual. The software user’s  
manual can be downloaded from the user’s manual icon.  
Chart 1  
 

Black Box Switch KV9612A User Manual
Bodum Coffeemaker 120801 User Manual
Bogen Stereo Amplifier CT100C User Manual
Bosch Power Tools Saw 0601598260 User Manual
Braun Electric Shaver 4875 User Manual
Broil King Gas Grill 9896 84 User Manual
Casio Digital Camera EX Z16 User Manual
CDA Washer 3Z9 User Manual
Cisco Systems Caller ID Box O 8637 01 User Manual
Cisco Systems Home Security System ASA5505BUNK9 User Manual