BRK electronic Smoke Alarm Smoke Alarms User Manual

OTHER FEATURES OF SMOKE ALARMS  
Battery (DC) operated smoke alarms: Provide protection even when electricity fails, provided the batteries are fresh  
and correctly installed. Units are easy to install, and do not require professional installation.  
AC powered smoke alarms: Can be interconnected so if one unit senses smoke, all units alarm. They do not operate  
if electricity fails. Units must be installed by a qualified electrician.  
User’s Manual  
Long Life Lithium Pow er  
Smoke Alarm  
Cat. 4000LB  
AC/DC powered smoke alarms: (AC with battery back-up): Can be interconnected so if one unit senses smoke,  
all units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be  
installed by a qualified electrician.  
Smoke alarms for the hearing impaired: Special purpose smoke alarms should be installed for the hearing  
impaired. They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With  
Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if  
electricity fails. Units must be installed by a qualified electrician. BRK Electronics® model 100S is an AC powered unit  
that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in alarm.  
All these units are designed to provide early warning of fires if located, installed and cared for as described in the user’s  
manual, and if smoke reaches them. If you are unsure which type of unit to install, refer to Chapter 2 of the National Fire  
Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire  
Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require  
specific units in new construction or in different areas of the home.  
SPECIAL COMPLIANCE CONSIDERATIONS  
This smoke alarm alone is not a suitable substitute for complete fire detection systems in places housing many people—like  
apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, nursing homes,  
day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a suitable substitute for  
complete fire detection systems in warehouses, industrial facilities, commercial buildings, and special-purpose non-  
residential buildings which require special fire detection and alarm systems. Depending on the building codes in your area,  
this smoke alarm may be used to provide additional protection in these facilities.  
The following information applies to all four types of buildings listed below: In new construction, most building  
codes require the use of AC or AC/DC powered smoke alarms only. In existing construction, AC, AC/DC, or DC  
powered smoke alarms can be used as specified by local building codes. Refer to NFPA 72 (National Fire Alarm Code)  
or NFPA 101 (Life Safety Code), local building codes, or consult your Fire Department for detailed fire protection  
requirements in buildings not defined as “households.”  
1. Single-Family Residence: Single family home, townhouse. It is recommended smoke alarms be installed on every  
level of the home, in every bedroom, and in each bedroom hallway.  
2. Multi-Family or Mixed Occupant Residence: Apartment building, condominium. This smoke alarm is suitable for  
use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection  
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not  
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.  
Ionization smoke alarms are generally more effective at detecting flaming fires which  
consume combustible materials rapidly and spread quickly. Sources of these fires may  
include paper burning in a wastebasket, or a grease fire in the kitchen.  
Photoelectric smoke alarms are generally more effective at detecting smoldering fires  
which smolder for hours before bursting into flame. Sources of these fires may include  
cigarettes burning in couches or bedding.  
Model  
4000LB  
For maximum protection, use both types of smoke alarms on each level of your home.  
M06-2086-001 8/99  
3. Institutions: Hospitals, day care facilities, long-term health care facilities. This smoke alarm is suitable for use in  
individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection  
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not  
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.  
INSIDE THIS MANUAL  
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.  
4. Hotels and Motels: Also boarding houses and dormitories. This smoke alarm is suitable for use inside individual  
sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in  
common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient  
warning to all residents or meet local fire protection ordinances/regulations.  
This user’s manual contains important information about your smoke alarm’s operation. If you are installing  
this smoke alarm for use by others, you must leave this manual—or a copy of it—with the end user.  
THIS USER’S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11” PAGES.  
BLACK page numbers reference the original printed document.  
RED page numbers reference this web version.  
LIMITATIONS OF SMOKE ALARMS  
Smoke alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning  
device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them.  
They are not foolproof.  
Smoke alarms cannot work without power. Battery operated units cannot work if the batteries are missing,  
disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units  
cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a  
power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or  
AC power, install both types of units.  
Smoke alarms cannot detect fires if the smoke does not reach them. Smoke from fires in chimneys or walls, on  
roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one  
unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed  
at night—and in the hallway between them.  
Smoke alarms may not detect fire on another floor or area of the home. For example, a stand-alone unit on the  
second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to  
escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every  
bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much  
protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend  
installing interconnected AC powered units with battery back-up (see “Other Features Of Smoke Alarms”) or professional  
fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning  
than stand-alone units since all units alarm when one detects smoke.  
Other Features Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Where To Install Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Where Not To Install Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Protecting Your Family From Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Important! Read Before Installing This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
If This Smoke Alarm Goes Into Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
If This Smoke Alarm Is Not Working Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4/5  
10-Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4/5  
All Rights Reserved. ©1999 BRK Brands, Inc.  
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122  
Consumer Affairs: (800) 323-9005  
1
 
PROTECTING YOUR FAMILY FROM FIRE  
HOW TO INSTALL THIS SMOKE ALARM  
Putting up smoke alarms is one step in protecting your family from fires. You must also reduce the chance a fire will  
start in your home, and have a plan for escaping safely if one does. To have a good fire safety program, you must:  
WARNING!  
Develop a family escape plan and practice it with everyone in your family, including small children. 1) Draw a floor plan  
of your home and identify at least two exits from each room and one way to get out of each bedroom without opening  
the door; 2) Decide on a meeting place a safe distance from home, and make sure everyone knows to wait there; 3)  
Know where to go to call the Fire Department from outside the home; 4) Make sure everyone—including all children—  
know what the alarm signal means and how to react to it. Teach them they must be prepared to leave the home by  
themselves if needed; 5) Hold fire drills every 6 months and practice how to escape safely. Show children how to check  
if doors are hot before opening them. Show them how to use an alternate exit if a door is hot and shouldn’t be opened.  
Teach them to stay close to the floor and crawl if necessary.  
The battery was shipped backwardsin the smoke alarm to keep it fresh. The smoke alarm  
cannot work until you remove the battery and reinstall it in the correct position (Follow  
polarity markings in the battery compartment).  
This smoke alarm has a battery guard which prevents it from closing unless a battery is  
installed. This warns you the unit will not operate without a battery.  
1
Install at least one smoke alarm on every level of your home, in every bedroom, and in every sleeping area.  
Keep alarms clean, and test them weekly. Replace smoke alarms immediately if they are not working properly. Smoke  
alarms that do not work cannot alert you to a fire.  
Keep at least one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders  
or other reliable means of escape from an upper floor in case stairs are blocked.  
Follow safety rules, and prevent hazardous situations: 1) Use smoking materials properly. Never smoke in bed.  
2) Keep matches or lighters away from children; 3) Store flammable materials in proper containers; 4) Keep electrical  
appliances in good condition and don’t overload electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and  
chimneys grease- and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable heaters  
and open flames, like candles, away from flammable materials; 8) Don’t let rubbish accumulate.  
3
2
5
4
WHAT TO DO IN CASE OF FIRE  
Don’t panic; stay calm. Follow your family escape plan. Your safe escape may depend on thinking clearly  
and remembering what you have practiced.  
5
Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.  
Feel doors with the back of your hand before opening them to see if they are hot. If a door is cool,  
open it slowly. Don’t open a hot door—use an alternate escape route.  
7
6
Cover your nose and mouth with a cloth (preferably wet). Take short, shallow breaths.  
Keep doors and windows closed, unless you need to escape through them.  
Meet at your planned meeting place outside your home, and do a head count to make sure everybody got  
out safely.  
Call the Fire Department as soon as possible from outside. Give your address, then your name.  
Never go back inside a burning building for any reason.  
Parts of Smoke Alarm (Cover Open)  
Cover of Smoke Alarm  
1
2
3
4
5
6
7
Open Heretab  
1
Open Heretab 3 Test button and  
power/alarm indicator  
Test button and power/alarm indicator  
Silencer button  
2
Cover hinge  
4
Silence button  
Smoke alarm base  
Contact your Fire Department for ideas on making your home safer and on creating your own family escape plan.  
Mounting slots  
DO NOT install any battery here!  
Install 9V battery here  
IMPORTANT! READ BEFORE INSTALLING SMOKE ALARM  
Read Where To Install Smoke Alarms” and Where Not To Install Smoke Alarms” before beginning. This unit monitors  
the air, and when smoke reaches its sensing chamber, it alarms. It can give you more time to escape before fire spreads.  
This unit can ONLY give an early warning of developing fires if it is installed, maintained and located where smoke can  
reach it, and where all residents can hear it, as described in this manual. This unit will not sense gas, heat, or flame. It  
cannot prevent or extinguish fires.  
WARNING!  
This unit will not alert hearing impaired residents. It is recommended that you install special  
units which use devices like ashing strobe lights to alert hearing impaired residents.  
Do not connect this unit to any other alarm or auxiliary device. It is a single-station unit that  
cannot be linked to other devices. Connecting anything else to this unit may prevent it from  
working properly.  
CAUTION!  
Do not install this unit over an electrical junction box. Air currents around junction boxes  
can prevent smoke from reaching the sensing chamber and prevent the unit from alarming.  
Only AC powered units are intended for installation over junction boxes.  
Do not stand too close to the unit when the alarm is sounding. It is loud to wake you in an  
emergency. Exposure to the horn at close range may harm your hearing. When testing the  
unit, step back when the horn starts sounding.  
Do not paint over the unit. Paint may clog the openings to the sensing chamber and prevent  
the unit from operating properly.  
3
 
To install this smoke alarm, follow these steps:  
This unit is designed to be mounted on the ceiling, or on the wall if necessary.  
Tools you will need:  
WEEKLY TESTING  
WARNING!  
Pencil  
NEVER use an open ame of any kind to test this unit. You might accidentally damage or set re to the unit or  
to your home. The built-in test switch accurately tests the units operation as required by Underwriters  
Laboratories, Inc. (UL). If you choose to use an aerosol smoke product to test the smoke alarm, be certain to  
use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards, and use it only as directed.  
Use of non-UL Listed products or improper use of UL Listed products may affect the smoke alarms sensitivity.  
Drill with 3/16(5 mm) drill bit  
Standard/Flathead screwdriver  
Hammer  
1. Hold base rmly and pull up on cover tab marked  
OPEN HERE.This will open the hinged cover. The cover  
may unsnap from the base if it's opened too far. This will not  
damage the unitthe cover hinge snaps back into place  
easily.  
1
2
5
7
It is important to test this unit every week to make sure it is working properly. Using the test button is the  
recommended way to test this smoke alarm. Press and hold the test button on the cover of the unit for  
5-20 seconds, or until the alarm sounds (the unit may continue to alarm for a few seconds after you release the button). If  
it does not alarm, make sure the unit is receiving power and test it again. If it still does not alarm, replace it immediately.  
During testing you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.  
4
2. Hold the smoke alarm base against the ceiling (or wall) and  
make a mark at the center of each of the mounting slots with  
a pencil.  
REGULAR MAINTENANCE  
3. Put the unit where it wont get covered with dust when you  
This unit has been designed to be as maintenance free as possible, but there are a few simple things  
you must do to keep it working properly.  
drill the mounting holes.  
3
Test it at least once a week.  
Test units used in RVs after the vehicle has been in storage, before every trip, and once a week while in use.  
Failure to test units used in RVs as described may remove your protection.  
4. Using a 3/16(5 mm) drill bit, drill a hole through each pencil  
mark.  
5. Insert the plastic screw anchors (in the plastic bag with  
screws) into the holes. Tap the screw anchors gently with a  
hammer, if necessary, until they are ush with the ceiling or  
wall.  
Clean the smoke alarm at least once a month; gently vacuum off any dust using your household  
vacuums soft brush attachment. 1. Open the cover and disconnect the battery. 2. GENTLY vacuum the  
inside of the cover and the sensor chamber. 3. Reconnect the battery. 4. Close the smoke alarm, and vac-  
uum the outside of the cover. 5. Test the smoke alarm. Never use water, cleaners or solvents since they  
may damage the unit.  
6. Tighten the screws (provided) into the screw anchors, then  
loosen them two turns.  
6
Relocate the unit if it sounds frequent unwanted alarms. See Where Not To Install Smoke Alarms.”  
When the battery becomes weak, the smoke alarm unit will chirpabout once a minute (the low battery warn-  
ing). This low battery warning should last for 30 days, but you should replace the battery immediately to con-  
tinue your protection.  
7. Fit the smoke alarm over the screw heads as shown. Close  
cover.  
8. If the smoke alarm cover does not line up the way you want it,  
rotate the base slightly and re-tighten the screws.  
Choosing a replacement battery:  
9. Activate the battery. With the cover open, remove and reinstall  
the battery so the terminals on the battery match the  
WARNING!  
terminals on the smoke alarm. Match +to +and -to -.”  
Push the battery in until it snaps in securely and cannot be  
shaken loose. If the battery is not snapped in completely, the  
unit cannot receive battery power. The smoke alarm may  
beep briey when you install the batterythis is normal.  
Use only the replacement batteries listed below. The unit may not operate properly with other  
batteries. Never use rechargeable batteries since they may not provide a constant charge.  
9
8
Your smoke alarm requires one standard 9V battery. The following batteries are acceptable as replacements: Eveready  
#216, (Energizer) #522, #1222; Duracell #MN1604; Gold Peak #1604P, #1604S; Rayovac 1604, D1604. You may also  
use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes.  
These batteries are available at many local retail stores.  
Once the battery is installed, the red power indicator light  
(behind the test button) will ash once a minute to show you  
the smoke alarm is working.  
IMPORTANT!  
10.Close the cover all the way.  
Most carbon zinc batteries have an average service life of 1 year; most alkaline batteries have an average service life  
of 1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the  
smoke alarm and the environment in which it is installed. All the batteries specied above are acceptable  
replacement batteries for this unit. Regardless of the manufacturers suggested battery life, you MUST replace the  
battery immediately once the unit starts chirping(the low battery warning).  
11.Test the smoke alarm. See Weekly Testing.”  
11  
10  
This smoke alarm shipped with a 10-Year Lithium battery. If you replace the original battery, you must replace it with  
a 10-Year Lithium battery for continued long-life protection.  
4
 
IF THIS SMOKE ALARM GOES INTO ALARM  
IF YOUR SMOKE ALARM IS NOT WORKING PROPERLY  
IMPORTANT!  
WARNING!  
Smoke alarms may not operate properly because of dead, missing or weak batteries, a build-up of dirt, dust or  
grease on the smoke alarm cover, or installation in an improper location. Clean the smoke alarm as described in  
Regular Maintenance,and install a fresh battery, then test the smoke alarm again. If it fails to test properly when you  
If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous  
situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm  
may result in injury or death. If the unit alarms and you are not absolutely certain of the  
source of the smoke, get everyone out of the house immediately.  
use the test button, or if the problem persists, replace the smoke alarm immediately.  
Never remove the batteries from a battery operated smoke alarm to stop an unwanted alarm  
(caused by cooking smoke, etc.). Removing the batteries disables the alarm so it cannot  
sense smoke, and removes your protection. Instead open a window or fan the smoke away  
from the unit. The alarm will reset automatically.  
Problem...  
You should...  
Smoke alarm alarms when  
no smoke is visible.  
Clean the smoke alarm. (See Regular Maintenance.)  
Check the location of the smoke alarm.  
(See Where To Install Smoke Alarms.)  
Responding To An Alarm  
During an alarm, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.  
If the unit alarms and you are not absolutely certain of the source of the smoke, get everyone out of the house  
immediately. Stay calm and follow your family escape plan. Stay as low to the ground as possible, and cover your  
mouth with a damp cloth. Never open a door before testing it to see if it is hot. Call the Fire Department from outside,  
and give them your address then name. Read What To Do In Case Of Firefor more information.  
You experience frequent unwanted alarms (like  
in response to cooking smoke).  
Check the location of the smoke alarm.  
(See Where To Install Smoke Alarms.)  
Smoke alarm chirpsintermittently.  
Check that the battery is installed correctly and is  
working properly. (See How to Install This Smoke  
Alarmand Weekly Testing.)  
Check the location of the smoke alarm.  
(See Where To Install Smoke Alarms.)  
If the unit alarms and you are certain that the source of smoke is not a recooking smoke or an extremely dusty  
furnace, for exampleopen a nearby window or door and fan the smoke away from the unit. This will silence the alarm,  
and once the smoke clears the unit will reset automatically.  
Clean the smoke alarm. (See Regular Maintenance.)  
Smoke alarm chirpsabout once a minute.  
Alarm horn doesnt sound during testing.  
Replace the battery. (See Regular Maintenance.)  
Check that the battery is installed correctly and is work-  
ing properly. (See How to Install This Smoke Alarm”  
and Weekly Testing.)  
Using the Silence Feature  
The silence feature can temporarily quiet an unwanted alarm for several minutes. To use this feature, press the Push to  
Silencebutton on the cover. The alarm will chirpabout once a minute (for up to 15 minutes) to remind you the alarm  
has been silenced. The chirpingwill stop when the unit returns to normal operation.  
Alarm horn will not silence when you  
push the Silence button.  
Do not ignore the alarm! Smoke present may be too  
dense, indicating an emergency situation.  
WARNING!  
If the smoke alarm is still not operating properly, and it is still under warranty, send it, shipping prepaid, along with  
original purchase receipt (or write down date purchased), to: BRK Brands, Inc., Attn.: Consumer Affairs, 3920 Enterprise  
Court, Aurora, IL 60504-8132. Enclose a note in the package describing what is wrong with the unit.  
The silence feature does not disable the unitit makes it temporarily less sensitive to smoke. For your  
safety, if smoke around the unit is dense enough to suggest a potentially dangerous situation, it will  
stay in alarm, or may re-alarm quickly. If you do not know the source of the smoke, do not assume it is  
an unwanted alarm. Not responding to an alarm can result in property loss, injury or death.  
WARNING!  
Do not try to x the unit yourselfthis will void your warranty!  
10-YEAR LIMITED WARRANTY  
Coverage: BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship  
under normal use for a period of ten years from the date of purchase. During the rst year after the date of purchase,  
BRK Brands, Inc. will replace any defective smoke alarm without charge. During the next nine years, BRK Brands, Inc.  
will replace any defective smoke alarm at a charge to you not to exceed BRK Brands, Inc.s cost. This is your exclusive  
warranty.  
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep  
the original sales receipt. Proof of purchase is required to obtain warranty performance. Dealers, service centers, or  
retail stores selling this product do not have the right to alter, modify or any way change the terms and conditions of this  
warranty. In new construction, if your smoke alarms were installed by a contractor, this warranty is valid for the  
homeowner at the time of installation from the date of original installation and is not transferable.  
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or  
misuse of the product, use on improper voltage, current or battery, use contrary to the operating instructions,  
disassembly, repair or alteration by anyone other than BRK Brands, Inc. Further, the warranty does not cover acts of  
God, such as re, ood, hurricanes and tornadoes.  
BRK Brands, Inc. shall not be liable for any incidental or consequential damages caused by the breach of any express or  
implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or tness for  
a particular purpose is limited in duration for 10 years. Some states, provinces, or jurisdictions do not allow the  
exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so  
the above limitations or exclusions may not apply to you. This warranty gives you specic legal rights, and you may also  
have other rights that vary from state to state, or province to province.  
Service: Units under warranty and in need of repair should be returned, shipping prepaid, to BRK Brands, Inc., Attn.:  
Consumer Affairs, 3920 Enterprise Court, Aurora, IL 60504-8132.  
Warranty: BRK Brands, Inc. makes no warranty, express or implied, written or oral, including that of merchantability or  
tness for any particular purpose, with respect to the battery.  
BRK Electronics® is a registered trademark  
of BRK Brands, Inc.  
M06-2086-001 8/99  
5
 

Belkin Network Card P73366 A User Manual
Black Box Switch S Video Audio Switch User Manual
Black Decker Camping Equipment PS50LRB User Manual
Bookendz Laptop Docking Station BE 10291 User Manual
Bosch Appliances Range HES3063U User Manual
Bose Headphones AM3834075 User Manual
Carrier Furnace 58HDV User Manual
Casablanca Fan Company Fan 59020 User Manual
CDA Cooktop RC 9020 User Manual
Christie Digital Systems Projector LX380 User Manual