PRODUCT DATASHEET
1-800-383-7323 US/CAN
Specifications
ENERGIZER CRV3 (ELCRV3)
Classification:
Chemical System:
Designation:
"Lithium Photo"
Non-Aqueous Lithium
Pending
Nominal Voltage:
Storage Temp:
Operating Temp:
Typical Capacity:
3.0 Volts
-40°C to 60°C (-40°F to 140°F)
-40°C to 60°C (-40°F to 140°F)
3000 mAh (to 2.0 volts)
(Rated at 200 mA at 21°C)
32 grams (1.1 oz.)
24 cubic centimeters (1.5 cubic inch)
2000 mA continuous (3000 mA pulse)
1.25 grams (0.04 oz.)
Industry Standard Dimensions
mm (inches)
Typical Weight:
Typical Volume:
Max Discharge:
Typical Li Content:
UL Listed:
This Battery has Underwriters
14.00 (0.551)
Laboratories component Recognition
14.40 (0.567)
MH12454
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
Shipping:
ø6.50 (0.256)
Typical
Global (except US):
United States:
49 CFR 173.185
14.10 (0.555)
Typical
Typical Discharge Characteristics
51.60 (2.031)
52.20 (2.055)
Constant Current Discharge
at 21 C
3.5
200 mA
28.20 (1.110)
28.60 (1.126)
3.0
2.5
2.0
1.5
This battery contains a Positive Temperature
Coefficient (PTC) safety device to limit current
during short circuit conditions.
1000 mA
0
4
8
12
16
Simulated Application Tests
Service, Hours
Typical Performance at 21°C (70°F)
Constant Power Discharge
Cutoff Voltage
at 21°C
3.5
3.0
2.5
2.0
1.5
Schedule
(time)
Drain
(mA)
Drain
(mW)
2.5V
(hours)
2.0V
(hours)
1.5V
(hours)
Continuous
Continuous
Continuous
200
1000
---
---
---
14.7
1.8
7.7
3
15.7
2.8
8.5
3.8
15.8
2.9
8.5
3.8
1000 mW
2000 mW
1000
2000
Continuous
---
0
2
4
6
8
10
Service, Hours
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4210H
Page 1 of 1
|