11) Unplug the fan before moving, cleaning or making repairs. NOTE: If for any
reason this unit requires service, return appliance to manufacturer or a similarly
qualified service agent to ensure safety.
12) To reduce the risk of fire or electric shock, do not use this fan with any solid-state
speed control device.
13) To disconnect, grip plug and pull from wall outlet. Never pull on the cord to
unplug.
14) For indoor use only.
WARNING
This fan has a grounded three
pronged plug intended to fit
into a three slot outlet. (A) An
adapter is available for
connecting three pronged
plugs into two slot outlets. (B)
When doing so, the green
grounding tab extending from
the adapter must be fastened
under the wall plate’s mounting
screw. The adapter should not
be used if a three-slot outlet is
available.
DO NOT DEFEAT THE
SAFETY PURPOSE OF THE
GROUNDED PLUG.
TECHNICAL SPECIFICATIONS
Voltage Rating
120V, 60Hz
Power Consumption 33W
Unit Size
Stand: 13.5 in. (W) x 13.5 in. (D) x 38.5 in. (H)
Table: 13 in. (W) x 11 in. (D) x 16.5 in. (H)
13.5 lbs
Unit Weight
3
PRODUCT DIAGRAM
A) Front Grill
B) Fan Blade
C) Securing Screw
D) Mounting Nut
E) Back Grill
F) Carrying Handle
G) Motor Shaft
H) Speed Control Knob
I) Oscillation Knob
J) Motor Housing
K) Fan Head Neck
L) Pole
M) Adjustable Height Knob
N) Stand Fan Base
O) Black Weight
P) Washer
Q) Locking Lever
R) Adjustable Tilt Knob
S) Range of Motion Screw
T) Range of Motion Hole
U) Securing Knob
V) Carriage Bolt
W) Table Fan Base
4
ASSEMBLY INSTRUCTIONS
Tools required: Phillips screwdriver (not included).
Remove the fan and packaging materials from the box.
Stand Fan Base Assembly:
1) Unscrew the locking lever from the bottom of the pole.
2) Turn the pole upside down and slide the opening in the center of the fan base over
the pole. Place the black weight onto the base followed by the washer.
3) Insert the threaded end of the locking lever into the hole of the washer and through
the base into the bottom of the stand. Turn the locking lever clockwise to secure
and tighten the base to the pole.
4) Turn the base over and set it on the floor.
5) On the neck of the fan head, remove the securing knob, carriage bolt and
adjustable tilt knob. Loosen the range of motion screw.
6) Slide the fan head neck over the top of the pole so that the range of motion screw
aligns with the range of motion hole.
7) Insert the carriage bolt into the square slot on the fan head neck and push through
the hole.
8) Tighten the range of motion screw. Screw on the securing knob and the adjustable
tilt knob.
Table Fan Base Assembly:
1) On the neck of the fan head, remove the securing knob, carriage bolt and
adjustable tilt knob. Loosen the range of motion screw.
2) Slide the fan head neck over the top of the table base so that the range of motion
screw aligns with the range of motion hole.
3) Insert the carriage bolt into the square slot on the fan head neck and push through
the hole.
4) Tighten the range of motion screw. Screw on the securing knob and the adjustable
tilt knob.
Fan Head Assembly:
1) Remove the black sleeve and mounting nut from the motor shaft.
2) Position the back grill over the motor shaft, fitting the holes in the back grill over the
knobs that protrude from the motor. Make sure the rear grill fits securely against
the motor housing and the handle is at the top.
5
3) Secure the back grill by screwing on the mounting nut. Turn clockwise and tighten
firmly.
4) Loosen the securing screw on the fan blade. Slide the fan blade onto the mounting
shaft with the shaft sleeve facing the motor. Align securing screw with flat groove in
the motor shaft and tighten with Phillips screwdriver.
5) Remove the small securing bolt from the bottom of the front grill. Position front grill
so logo is horizontal and make sure the grill clips are open. Secure the top tab to
the back grill. Fasten the grills together with securing bolt. Hold the front grill
against the rear grill and snap the grill clips closed to complete the assembly.
Converting:
1) On the neck of the fan head, remove the securing knob, carriage bolt and
adjustable tilt knob. Loosen the range of motion screw.
2) Remove the fan head from the old base and slide over the new base so that the
range of motion screw aligns with the range of motion hole.
3) Insert the carriage bolt into the square slot on the fan head neck and push through
the hole.
4) Tighten the range of motion screw. Screw on the securing knob and the adjustable
tilt knob.
6
OPERATING INSTRUCTIONS
1) Set the fan on a stable, level surface.
2) Confirm that the Speed Control Knob is set to “O” (off). Plug the cord into a
standard 120V A/C outlet.
3) Adjust to the desired speed setting:
O: Off
I: Low Speed
II: Medium Speed
III: High Speed
4) The fan can operate in oscillation or stationary mode. Press the Oscillation Knob
down to activate the oscillating mode. To stop oscillation, pull knob up.
5) Unplug the fan when not in use.
Adjustment Instructions:
• To adjust the angle of the fan head, loosen the adjustable-tilt knob and move the
fan head to the desired angle. Firmly tighten the knob to secure into place.
• To adjust the height of the stand fan, turn the adjustable height knob counter-
clockwise to loosen the stand. Adjust the fan to the desired height, then firmly
tighten to secure into place.
CLEANING/MAINTENANCE
• Set the Speed Control Knob to off and unplug the unit.
• Clean the fan head, base, and pole using a damp cloth and a mild detergent, if
necessary. Make certain all detergent residue is removed.
• Never use abrasive cleaning agents or solvents. This may cause damage or
deterioration to the surface of the unit.
• Do not immerse the fan in any form of liquid. Do not allow water to drip on or into
the fan motor housing.
Fan Blade Cleaning:
1) Make certain the fan is unplugged. Unlock the metal clips on the front grill and
remove the front grill. Use a Phillips screwdriver to loosen the securing screw and
remove the fan blade.
2) The fan blade and grill may be cleaned with a damp cloth and mild detergent.
7
3) Reassemble the fan after the parts have dried completely. To do so, replace the
fan blade, tighten the securing screw, and secure the front grill. Do not plug the fan
into an electrical outlet until it is fully reassembled.
STORAGE
When not in use, store the fan in a cool, dry location. To prevent dust and dirt build-up,
use the old packaging to repack the unit.
Printed in China
8
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air FCM-30 to be free from
defects in material and workmanship for the applications specified in its operation
instruction for a period of ONE (1) year from the date of original retail purchase in the
United States or Canada.
If the unit exhibits a defect in normal use, Soleus International, Inc. will, at its option,
either repair or replace it, free of charge within a reasonable time after the unit is
returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this
Warranty Certificate along with a copy of the original purchase invoice.
This Warranty Does Not Cover
1) Damage, accidental or otherwise, to the unit while in the possession of a consumer
not caused by a defect in material or workmanship.
2) Damage caused by consumer misuse, tampering, or failure to follow the care and
special handling provisions in the instructions.
3) Damage to the finish of the case, or other appearance parts caused by wear.
4) Damage caused by repairs or alterations of the unit by anyone other than those
authorized by Soleus International Inc.
5) Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY
ARE LIMITED TO A ONE-YEAR DURATION OF THIS EXPRESS LIMITED
WARRANTY. SOLEUS INTERNATIONAL, INC. DISCLAIMS ANY LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS
INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS
UNIT.
As some states do not allow the limitation or exclusion of incidental or consequential
damages, or do not allow limitation on implied warranties, the above limitations and
exclusions may not apply to you. This warranty gives you specific legal rights, and you
may also have other rights that vary from state to state.
For Warranty, Technical Support, Customer Service, Missing or Defective Parts,
before returning to your retailer, please call (888) 876-5387.
Or Write To:
Soleus International Inc.
9451 Telstar Ave.
El Monte, CA 91731 USA