Soho Switch FSD 800 User Manual

SOHOConnect Series  
FSD-800  
8-port 10/100Mbps Ethernet Switch  
FSD-8080 User's Manual  
 
i
Table of Contents  
CHAPTER 1............................................................................1  
GENERAL INTRODUCTION ......................................................1  
Checklist............................................................................1  
Introduction.......................................................................1  
Features ............................................................................3  
CHAPTER 2............................................................................5  
HARDWARE DESCRIPTION......................................................5  
Front Panel .......................................................................5  
Rear Panel ........................................................................6  
Hardware Installation.......................................................7  
Configuration....................................................................8  
Switch Operation.............................................................10  
CHAPTER 3..........................................................................15  
TROUBLESHOOTING .............................................................15  
APPENDIX A........................................................................17  
SPECIFICATIONS:..................................................................17  
FSD-800 User's Manual  
1
 
This page is intentionally left blank.  
2
SOHOConnect Series  
 
Chapter 1  
General Introduction  
Checklist  
Check the contents of your package for following parts:  
¨
¨
¨
The Fast Ethernet Switch  
Power Cord  
User’ s Manual  
If any of these pieces are missing or damaged, please contact  
your dealer immediately, if possible, retain the carton including  
the original packing material, and use them against to repack the  
product in case there is a need to return it to us for repair.  
Introduction  
The FSD-800, 8-port 10/100Mbsp Ethernet Switch is designed to  
allow simultaneous transmission of multiple packets via an  
internal high-speed data channel. This means that it can partition  
FSD-800 User's Manual  
1
 
a network more efficiently than bridges or routers in most  
environments.  
In the following sections, the term “Switch” will represent  
Planet’ s FSD-800, and “switch” for third part Ethernet switches.  
This Switch is a highly reliable network switch and is the ideal  
device for bridging Ethernet to Fast Ethernet workgroups or  
networks. Simple and cost-effective, the Switch complies with  
IEEE802.3u, IEEE802.3, 100Base-TX, and 10Base-T. Therefore,  
the Switch will be the fast being recognized as one of the most  
important building blocks for today networking technology.  
Compact in size and designed for Plug and Play installation, the  
Switch allows the network administrator to simply connect the  
network and power cables and the switching/bridging functions  
begin automatically. No hardware or software configurations are  
required.  
The front panel of the Switch provides LED indicators for easy  
recognition of the switch operation status and for troubleshooting.  
These LED indicators display the power status for the system and  
link, speed, full duplex, and receive status for each port.  
With 8-port Fast Ethernet Switching designed specifically for  
2
SOHOConnect Series  
 
connecting workgroup devices and desktops, companies no  
longer have to invest in expensive and inflexible switches  
engineered primarily for backbone implementations. Instead,  
companies can deploy scaleable, affordable switches that increase  
the aggregate bandwidth of the network by boosting throughput  
to the workgroups that need it most.  
Features  
¨
¨
¨
¨
¨
8-port 10/100base-TX Auto-Negotiation Ethernet Switching  
Hub  
Complies with the IEEE802.3 Ethernet and IEEE802.3u Fast  
Ethernet standard  
Features Store-and-Forward architectures with wire-speed  
filtering and forwarding rates  
Full/Half-Duplex capability on every TX ports, total  
bandwidth is up to 200Mbps/port  
Support up to 4K Uni-cast address, Layer 2 address resolution-Self  
Learning  
¨
¨
¨
¨
Broadcast storm control  
IEEE802.3x compliant full-duplex flow control  
Half-duplex flow control  
100~240VAC Full range internal power supply  
FSD-800 User's Manual  
3
 
¨
¨
LED indicators for simple diagnostics and management  
Port#8 provides an extra port for MDI and MDI-X mode PC  
or hub Uplink.  
¨
Plug and Play  
4
SOHOConnect Series  
 
Chapter 2  
Hardware Description  
This section describes the hardware features of the Switch. For  
easier management and control of the Switch, familiarize  
yourself with its display indicators, and ports. Front panel  
illustrations in this chapter display the unit LED indicators.  
Before connecting any network device to the hub, read this  
chapter carefully.  
Front Panel  
The unit front panel provides a simple interface monitoring the  
Switch. It includes a power indicator for each port.  
Figure 1. Front Panel of FSD-800  
 
LED indicators  
LED  
Color Description  
Function  
Power  
(PWR)  
Green This indicator lights green when the hub is  
receiving power, otherwise, it is off.  
Link/ Act Green This indicator green when the port is  
connected to a either 10Mbps Ethernet or  
100Mbs Fast Ethernet station , If the station  
to which the hub is connected is powered  
off, or if there is a problem with the link, the  
LED will remain off.  
And the indicator blinking green when the  
data will be received to all other connected  
ports.  
100  
Green This indicator green when the port is  
connected to a 100Mbps Fast Ethernet  
station. If the station to which the hub is  
connected is powered off,  
a
10Mbps  
Ethernet station, or if there is a problem with  
the link, the LED will remain off.  
FDX/COL Green Lit: Full duplex operation  
Unlit: Half duplex operation  
Blink: indicates data collisions on the  
respective Ethernet segment of this port.  
Whenever collision is detected, the  
respective COL indicator will briefly blink  
a
Rear Panel  
The rear panel of the Switch indicates an AC-jack power socket,  
which accepts 100~240VAC Power inlet for FSD-800.  
6
SOHOConnect Series  
 
100V~240VAC  
50~60Hz  
Figure 2. Rear Panel of FSD-800  
Hardware Installation  
1. Place the Switch on a smooth surface  
2. Connect the output cord of power supply to the AC-jack.  
3. Connect hub or PC to one port of the Switch using Category  
3/4/5 UTP/STP cabling.  
4. Connect another hub or PC to the other port of Switch by  
following the same process as described in Step 3.  
Notice:  
Cable distance for FSD-800  
The cable distance between the Switch and hub/PC should  
not exceed 100 meter.  
Make sure the wiring is correct  
It can be used Category 3/4/5 cable in 10Mbps operation.  
To reliably operate your network at 100Mbps, you must  
use an Unshielded Twisted-Pair (UTP) Category 5 cable, or  
better Data Grade cabling. While a Category 3 or 4 cable  
FSD-800 User's Manual  
7
 
may initially seem to work, it will soon cause data loss.  
All kinds of hub/PC can connect to switch by using straight-  
through wires. The hub provides one additional RJ45 connector  
that is converted from port 1, labeled “Uplink” port. Either port 8  
or Uplink port can be used at one time.  
Configuration  
100Mbps Server to 10Mbps Hub  
Plug one end of the Category 5 UTP Cable into any one port of  
the Switch, and the other end of this cable into the RJ-45 of Fast  
Ethernet Adapter in the server. The cable length between these 2  
connecting points should not exceed 100 meters.  
Plug one end of the Category 3 UTP Cable into “Uplink” port of  
the Switch, and the other end of this cable into any port of the  
10Mbps Ethernet hub. The cable length between these 2  
connecting points should not exceed 100 meters.  
8
SOHOConnect Series  
 
Uplink  
Figure 3. 100Mbps File server to Hubs Connection  
10Mbps Hub to 100Mbps Hub  
Plug one end of the Category 5 UTP Cable into one port of the  
Switch, and the other end of this cable into “Uplink” port of the  
100Mbps Fast Ethernet Hub. The cable length between these 2  
connecting points should not exceed 100 meters.  
Plug one end of the Category 3 UTP Cable into one port of the  
Switch, and the other end of this cable into “Uplink” port of the  
10Mbps Ethernet Hub. The cable length between these 2  
connecting points should not exceed 100 meters.  
FSD-800 User's Manual  
9
 
Switch Operation  
Address Table  
The Switch is implemented with an address table. This address  
table composed of many entries. Each entry is used to store the  
address information of some node in network, including MAC  
address, port no, etc. The information comes from the learning  
process of Ethernet Switch.  
Learning  
When one packet comes in from any port. The Ethernet Switch  
will record the source address, port no. and the other related  
information in address table. This information will be used to  
decide either forwarding or filtering for future packets.  
Forwarding & Filtering  
When one packet comes from some port of the Ethernet Switch,  
it will also check the destination address besides the source  
address learning. The Ethernet Switch will lookup the address  
table for the destination addresses. If not found, this packet will  
be forwarded to all the other ports except the port which this  
packet comes in. And these ports will transmit this packet to the  
network it connected. If found, and the destination address is  
10  
SOHOConnect Series  
 
located at different port from this packet comes in; the Ethernet  
Switch will forward this packet to the port where this destination  
address is located according to the information from address table.  
But, if the destination address is located at the same port with this  
packet comes in, when this packet will be filtered. Thereby  
increasing the network throughput and availability  
Store-and-Forward  
Store-and-Forward is one type of packet-forwarding techniques.  
A Store-and-Forward Ethernet Switch stores the incoming frame  
in an internal buffer, do the complete error checking before  
transmission. Therefore, no error packets occurrence, it is the  
best choice when a network needs efficiency and stability.  
The Switch scans the destination address from the packet header,  
searches the routing table provided for the incoming port and  
forwards the packet, only if required. The fast forwarding makes  
the switch attractive for connecting servers directly to the  
network, thereby increasing throughput and availability. However,  
the switch is most commonly used to segment existing hubs,  
which nearly always improves overall performance. An Ethernet  
Switch can be easily configured in any Ethernet network  
environment to significantly boost bandwidth using conventional  
FSD-800 User's Manual  
11  
 
cabling and adapters.  
Due to the learning function of the Ethernet switch, the source  
address and corresponding port number of each incoming and  
outgoing packet are stored in a routing table. This information is  
subsequently used to filter packets whose destination address is  
on the same segment as the source address. This confines  
network traffic to its respective domain, reducing the overall load  
on the network.  
The Switch performs “Store-and-forward” therefore, no error  
packets occur. More reliably, it reduces the re-transmission rate.  
No packet loss will occur.  
Auto-Negotiation  
The STP ports on the Switch have built-in "Auto-Negotiation."  
This technology automatically sets the best possible bandwidth  
when a connection is established with another network device  
(usually at Power On or Reset). This is done by detect the modes  
and speeds at the second of both device is connected and capable  
of. Both 10Base-T and 100Base-TX devices can connect with the  
100Base-TX port in either Half- or Full-Duplex mode.  
12  
SOHOConnect Series  
 
If attached device is:  
100Base-TX port will set to:  
10Mbps  
· 10Mbps, no auto-negotiation  
· 10Mbps, with auto-negotiation  
· 100Mbps, no auto-negotiation  
· 100Mbps, with auto-negotiation  
10/20Mbps (10Base-T/Full-Duplex)  
100Mbps  
100/200Mbps  
(100Base-TX/Full-Duplex)  
FSD-800 User's Manual  
13  
 
This page is intentionally left blank.  
14  
SOHOConnect Series  
 
Chapter 3  
Troubleshooting  
This chapter contains information to help you solve problems.  
If the Switch is not functioning properly, make sure the Switch  
was set up according to instructions in this manual.  
The Link LED is not Lit  
Solution:  
Make sure the switch configuration is consistent with the  
connecting device  
Check the cable connections.  
Performance is bad  
Solution:  
Check the full duplex status of the Ethernet Switch. If the  
Ethernet Switch is set to full duplex and the partner is set to half  
duplex, then the performance will be poor.  
Some stations can not talk to other stations located on the  
other port  
Solution:  
 
The address table may contain older information than of the  
address table of that node. Please power down to refresh the  
address information.  
16  
SOHOConnect Series  
 
Appendix A  
Specifications:  
General (Ethernet)  
IEEE 802.3 10Base-T Ethernet  
Standards:  
IEEE 802.3u 100 Base-TX Fast Ethernet  
ANSI/IEEE Std 802.3 N-way auto-negotiation  
IEEE 802.3 Frame types: Transparent  
IEEE 802.3 MAC layer frame size: 64 - 1518 Bytes  
CSMA/CD  
Protocol:  
Data Transfer Rate:  
Ethernet:  
Fast Ethernet:  
10Mbps (half duplex)  
20Mbps (full duplex)  
100Mbps (half duplex)  
200Mbps (full duplex)  
Topology:  
Star  
General (Cabling)  
10Base-T:  
Network Cables:  
2-pair UTP Cat. 3,4,5 (100 m, maximum)  
EIA/TIA- 568 100-ohm STP (100 m, maximum)  
100Base-TX:  
2-pair UTP Cat. 5 (100 m, maximum)  
EIA/TIA-568 100-ohm STP (100 m, maximum)  
Number of Ports:  
8 - STP ports  
Media Interface  
Exchange:  
Cascade RJ-45 shared with port#1  
Hardware Physical /Environmental Specification  
DC inputs  
100~240VAC, 50~60Hz  
12 watts maximum  
System : Power  
Power Consumption  
LED Indication  
Port: 3 LED Indicators per port  
(LINK/ACT, 100, FDX/ COL)  
Operating  
Temperature  
0 ~ 50 degree C  
Storage Temperature  
-20  
~
70 degree C  
 
General (Ethernet)  
10% ~ 90% non-condensing  
251 x 118 x 37 mm  
Humidity  
Dimensions  
EMI  
FCC Class A, CE Mark Class A  
Performance  
Store-and-forward  
Transmission  
Method  
Filtering Address  
Table  
4 K entries / device  
Packet  
Filtering/Forwarding  
Rate  
148,800pps per port (for 100Mbps)  
14,880pps per port (for 10Mbps)  
Automatic update  
MAC Address  
Learning  
18  
SOHOConnect Series  
 

Sharp Refrigerator SJ F602SP User Manual
Snapper Snow Blower 1690497 User Manual
Sony Cassette Player WM EX122 User Manual
Sony Digital Camera 560TVL User Manual
Sony Personal Computer VPCSA User Manual
Specialized Cyclometer CylcoComputer User Manual
Sybase Personal Computer Desktop User Manual
Sylvania Clock Radio SKCR2613 User Manual
Sylvania DVD VCR Combo SRZ3000 User Manual
Sylvania Flat Panel Television LC370SL8 User Manual