Preface  
Thank you for purchasing this user system interface cable (HS2318ECH61H) for the Renesas’s  
original microcomputer H8/2318 series.  
The HS2318ECH61H is a user system interface cable that connects an H8/2318 series E6000  
emulator (HS2338EPI61H; hereinafter referred to as the emulator) to the IC socket for a  
FP-100B/TFP-100B package for the H8S/2318 series MCU on the user system.  
i
 
Contents  
ii  
 
Section 1 Configuration  
CAUTION  
Use an IC149-100-054-B51 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/TFP-  
100B package IC socket on the user system.  
Figure 1 shows the configuration of the HS2318ECH61H user system interface cable for the  
FP-100B/TFP-100B package.  
Figure 1 HS2318ECH61H User System Interface Cable  
1
 
 
Table 1 lists the HS2318ECH61H components. Please make sure you have all of these components  
when unpacking.  
Table 1  
HS2318ECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
Cable body  
Cable head  
IC socket  
1
1
1
1
Flat cable  
For the FP-100B/TFP-100B package  
Socket cover  
For installing an FP-100B/TFP-100B-packaged  
MCU  
5
6
Screws (M2.6 x 12 mm)  
Screws (M2.6 x 6 mm)  
4
4
For fastening cable head (with four flat washers)  
For installing an FP-100B/TFP-100B-packaged  
MCU (with four flat washers)  
7
Documentation  
1
User’s manual for HS2318ECH61H (this manual)  
2
 
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors will  
be damaged.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
3
 
 
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
 
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of  
the IC socket for an FP-100B/TFP-100B package, and fasten it to the user system before soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-100B/TFP-100B package to the user system. Be sure  
to completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
5
 
 
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-100B/TFP-100B package on the user system with pin 1 on  
the user system interface cable head, and insert the user system interface cable head into the IC  
socket on the user system, as shown in figure 3.  
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Philips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
6
 
 
Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on  
the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each screw  
should be tightened a little at a time, alternating between screws on opposing corners. Take special  
care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from  
being damaged by overtightening the screws or twisting the components.  
Cable head  
User system  
Figure 3 Connecting User System Interface Cable to User System  
7
 
2.2.5  
Fastening Cable Body  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jigs.  
Remove jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
 
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an FP-100B/TFP-100B package (IC149-100-054-B51: manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat  
different from those of the actual chip's mount pad.  
17.10 min  
13.80 max  
0.5 24 = 12.00 ± 0.05  
0.50 ± 0.05  
0.30 ± 0.05  
Unit: mm  
Figure 5 Recommended Dimensions for Mount Pad  
9
 
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
29.0  
16.5  
63.5  
Unit: mm  
Tolerance: ±0.5 mm  
Figure 6 Dimensions for User System Interface Cable Head  
10  
 
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
 
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Philips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws  
(M2.6 x 6 mm; with four flat washers). Take special care, such as manually securing the IC socket  
soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting  
the components.  
12  
 
 
Figure 8 Installing MCU to User System  
13  
 
Section 4 Verifying Operation  
1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the  
procedures described in the H8S Series E6000 Emulator User’s Manual (HS2000EPI61HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins with the MEMORY_FILL command (emulator command).  
If an error is detected, recheck the soldered IC socket and the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock sources  
as the MCU clock: an emulator internal clock and an external clock on the user system. For  
details, refer to the Emulator Supplementary Information (HS2338EPI61HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ), by using the CLOCK  
command (emulator command).  
To use the external clock on the user system  
Select external clock t or t2 with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator. Connect a crystal oscillator to the  
EXTAL and XTAL terminals for the system clock (φ), or input the external clock from the  
EXTAL terminal on the cable head. Select the external clock as the system clock (φ), by  
using the CLOCK command (emulator command). For details, refer to section 22, Clock  
Pulse Generator, in the H8S/2338 Series, H8S/2328 Series, H8S/2318 Series Hardware  
Manual.  
Figure 9 shows oscillator circuit on the user system interface cable.  
Figure 9 Oscillator Circuit  
14  
 
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different from  
those of the MCU.  
3. This user system interface cable is specifically designed for the HS2338EPI61H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 10.  
Figure 10 User System Interface Cable Location Example  
6. The P1 jumper connector is used for testing. Do not remove the inserted jumper pin.  
15  
 
 
Figure 11 P1 Short Connector  
16  
 

Raypak Swimming Pool Heater 155C User Guide
Remington Power Tools Chainsaw EL 3 User Guide
Renesas Switch M3062PT EPB User Guide
Ricoh All in One Printer 70eI92 User Guide
Samson Headphones 77 User Guide
Samson Musical Instrument Amplifier AG300 Guitar Transmitter User Guide
Samsung Home Theater System HT 410HD User Guide
Samsung Security Camera SCC 643AP User Guide
Sanyo Security Camera VDC HD3100 HD3100P User Guide
Sceptre Technologies Flat Panel Television E195BD SHD User Guide