Regency Liberty L900 Gas Fireplace
L900-1 Gas Fireplace
Framing Dimensions:
Model
L900-NG1
Natural Gas
L900-LP1
Propane
Fuel Type
Framing Dimensions
Description
L900-1
52” (1321mm)
J
Framing Width
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size
5” W.C.(1.25 kPa)
3.5” W.C. (0.87 kPa)
1.6” W.C. (0.40 kPa)
#30 DMS
12” W.C. (3.00 kPa)
10” W.C. (2.49 kPa)
6.4” W.C. (1.59 kPa)
#49 DMS
K***
L
Framing Height***
50-3/4” (1289mm)*** + Hearth
26-1/2” (673mm)
60” (1524mm)
Framing Depth
M
N
Minimum Height to Combustibles
Corner Wall Length
63-15/16” (1624mm)
90-7/16” (2286mm)
53” (1346mm)
O
P
Corner Facing Wall Width
Vent Centerline Height
Non-combustible facing height
Gas Connection Opening Height
Gas Connection Height
Gas Connection Inset
Gas Connection Opening Width
Minimum Input
Altitude 0-4500 ft. (0-1372m)
28,000 BTU/h (8.20 kW)
31,000 BTU/h (9.08 kW)
Q
R
17-7/16” (443mm)
2” (51mm)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
41,500 BTU/h (12.16 kW)
5” Inner / 8” Outer
38,500 BTU/h (11.28 kW)
5” Inner / 8” Outer
S
11-1/4” (286mm)
6” (152mm)
T
Vent Sizing
U
5” (127mm)
***Important: Framing height requires consideration of the hearth
Approved Venting Systems
depth. Dimension K = K + the thickness of installed hearth.
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
Unit Dimensions:
Unit Dimensions
Description
L900-1
A
B
C
D
E
F
G
H
I
Firebox Width w/ Standoff
Rear Firebox Width
Firebox Height
51-1/2” (1308mm)
40-5/8” (1032mm)
41-3/8” (1051mm)
50-3/8” (1270mm)
27” (686mm)
Height w/ Standoff
Unit Depth
Height to Vent
44-1/2” (1130mm)
32-1/16” (814mm)
33-5/8” (853mm)
3” (76mm)
Fireplace Opening Height
Fireplace Opening Width
Height to Fireplace Opening
Non-Combustible Requirements:
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifications may change without notice.
You must use the actual manual for exact installation specifications.
WARNING
Failure to maintain required clearances is a major cause of chimney related fires.
Installation of this fireplace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifications
are subject to change without notice.
|
Radio Shack Speaker System 40 1430 User Guide
RCA CD Player RP 9300 User Guide
RCA Tablet RCT6672W23 User Guide
RCA TV Antenna VH126N User Guide
Realistic Stereo Receiver PRO 2004 User Guide
Reliable Sewing Machine MSK 8400B User Guide
Rheem Water Heater 136 1826 User Guide
Ricoh Answering Machine 43 3808A User Guide
Ryobi Blower RY42110 User Guide
Samsung Switch SCM 100R User Guide