®
AUX2000
Auxiliary Control
Box
Installation/
Operation Manual
C916M (11/90)
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
INSTALLATION/OPERATION MANUAL
AUX2000 AUXILIARY CONTROL BOX
FOR THE COAXITRON® AND
WIRETRON RECEIVER/DRIVER
1.0 WARNINGS
Prior to installation and use of this product, the follow-
ing WARNINGS should be observed.
4. Only use replacement parts recommended by
Pelco.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all Lo-
cal codes.
5. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
between line and exposed parts to verify the ex-
posed parts have not been connected to line cir-
cuitry.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is de-
signed for Indoor use only and it must not be in-
stalled where exposed to rain and moisture.
6. The installation methods and materials should be
capable of supporting four (4) times the weight of
the AUX2000.
3. The product may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C916M (11/90)
1
2.0 SCOPE
3.2 RECOMMENDED CONTROLS
CX9024RX
Coaxitron® receiver in weatherproof
The information contained within this manual covers
the installation and operation of the AUX2000.
box for 24 VAC pan/tilts, zoom lens,
24 VAC camera power, and four ac-
cessory functions.
3.0 DESCRIPTION
The AUX2000 is an auxiliary control box for the
Coaxitron® and Wiretron receiver/drivers. It enables the
logic level AUX 1-3 signals from the Coaxitron® and
Wiretron receiver/drivers to control devices such as
motors for motor operated gates, lights for parking ar-
eas, or power relays for high power requirements.
CX9024RX-12V SameasCX9024RXexceptsupplied
with 12 VDC camera power.
CX9024RXI
Coaxitron® receiver. Same as
CX9024RX, except for indoor use.
CX9024RXI-12V Same as CX9024RXI except sup-
plied with 12 VDC camera power.
3.1 MODEL NUMBERS
AUX2000
Auxiliary control box for the
Coaxitron® and Wiretron receiver/
drivers.
CX9115RX
Coaxitron® receiver in weatherproof
box for 120 VAC pan/tilt, zoom lens,
120 VAC camera power, and four
accessory functions.
CX9115RXI
CX9224RX
CX9224RXI
Same as CX9115RX except for in-
door use.
Same as CX9024RX except with 24
VAC power input.
Same as CX9224RX except for in-
door use.
CX9224RXI-12V Same as CX9224RXI except with 12
VDC camera power.
WX8024RX
Wiretron receiver in weatherproof
box for 24 VAC pan/tilts, zoom lens,
24 VAC camera power, and four ac-
cessory functions.
WX8024RXI
WX8224RXI
WX8115RX
Same as WX8024RX except for in-
door use.
Same as WX8024RXI except with
24 VAC power input.
Wiretron receiver in weatherproof
box for 120 VAC pan/tilts, zoom
lens, 120 VAC camera power, and
four accessory functions.
2
Pelco Manual C916M (11/90)
4.0 INSTALLATION
Refer to the following instructions when installing the
AUX2000 auxiliary control box for the Coaxitron® and
Wiretron receiver/drivers.
1. Determine the location for the AUX2000 auxiliary
control box for the Coaxitron® or Wiretron receiver/
drivers. To determine the mounting location, con-
sider the distance between the AUX2000 auxiliary
control box for the Coaxitron® and Wiretron receiver/
drivers and auxiliary functions used. Attention
should be given to the wire distance table shown
above.
2. Using the AUX2000 auxiliary control box for the
Coaxitron® and Wiretron receiver/drivers box as a
template, mount the box to the desired location
using the fasteners (not supplied) which will sup-
port the full load of the unit.
3. Assemble the mating connector as described in
Section 4.1.
4. Connect the auxiliary device as shown in Figure 1.
5. Plug the AUX2000 into a 120 VAC source.
1
2
3
P/T COMMON
MANUAL IRIS
LEFT
5
DOWN
6
UP
7
RIGHT
8
GROUND
FEED THROUGH TO ENCLOSURE
9
CAMERA AC (HIGH)
IRIS
FOCUS
ZOOM
LENS COMMON
CAMERA AC (LOW)
10
11
12
13
14
OUTPUT TO A LAMP
15
16
18
AUX 1
AUX 2
AC HI
OUTPUT TO A MOTOR
RELAY OUTPUT
1
2
4
3
17
19
AUX 3
AC NEUTRAL
OUTPUT CIRCUITS ARE RATED FOR 120 VAC,
1 AMP, (120 VA) MAXIMUM EACH
Figure 1. Typical Output Circuits
Pelco Manual C916M (11/90)
3
4.1 MATING CONNECTOR ASSEMBLY
4. The contact pins supplied with the mating connec-
tor are the “crimp” type which may also be sol-
dered if you so desired (item 4).
Installation and/or testing will require you to assemble
the connector parts provided. Fabricate the intercon-
necting cable according to the following steps (refer-
ence Figure 2).
5. After crimping or soldering the contact pins to the
conductors, push them into the proper holes in the
connector until they snap in place.
1. Slide partAof the cable clamp (item 1) over the end
of the cable (item 1, part C) with the threaded end
of the cable clamp facing the connector (item 5).
NOTE: Contacts cannot be removed from the
connector without the use of the appropriate
AMP extraction tool which is available from
Pelco.
2. If the cable has a diameter less than 1/2 inch (1.3 cm),
slide the rubber boot (item 2) over the end of the
cable and pull through the cable clamp to so that the
boot encases the cable and forms a good seal.
6. Slide partAof the cable clamp toward the connec-
tor and screw the parts together.Attach part B (item
1) onto part A and connect both parts with the
screws provided.
3. Strip back the cable jacket approximately 1-1/4
inches (3.2 cm) and separate the individual con-
ductors (item 3).
7. Connect the cable assembly to the unit and seat
the connector by twisting the locking collar until it
snaps into position.
5
1
threaded end of
cable clamp
A
B
C
STEP 1
FLEXIBLE RUBBER BOOT
5
1
A
B
STEP 2
C
2
5 **
3
1
4
A
B
STRIP 1/8"
C
STEPS 3-7
CRIMP
INSULATION
CRIMP
WIRE
OUTSIDE
JACKET
OF CABLE
STRIP 1"
4
1
5
2
1
1
**
3
8
9
ITEM 5 DETAIL
4
6
15
10
16
23
3
9
14
22
28
10
15
21
20
25
28
7
33
14
11
29
37
34
26
16
15
FRONT VIEW
FRONT VIEW
FRONT VIEW
37-PIN CONNECTOR
28-PIN CONNECTOR
16-PIN CONNECTOR
3
1
3
1
4
7
4
6
THE MOST COMMONLY USED
CONNECTOR PIN-OUT CONFIG-
URATIONS ARE SHOWN HERE.
REFERENCE THE CONNECTOR
DRAWING APPLICABLE TO
YOUR SITUATION.
11
8
9
7
14
12
FRONT VIEW
9-PIN CONNECTOR
FRONT VIEW
14-PIN CONNECTOR
Figure 2. Mating Connector Assembly Diagram
4
Pelco Manual C916M (11/90)
5.0 OPERATION
The AUX2000 is operated by the Coaxitron® or
Wiretron controller.
5.1 SYSTEM TEST
Using the systems controller, verify that the auxiliary
devices function.
6.0 TROUBLESHOOTING GUIDELINES
In the event that the auxiliary equipment do not work,
retrace the wiring and verify correctness and check the
fuse to make sure it did not open.
Correct all errors in wiring and replace the fuse if
opened.
Retry to operate the auxiliary equipment.
If the auxiliary equipment does still not operate, call
Pelco’s Technical Assistance Program (TAP) line at
1-800-289-9100. The TAP Line is available 24 hours
a day, seven days a week.
Pelco Manual C916M (11/90)
5
7.0 AUX2000 MECHANICAL PARTS LIST
Description
Part Number
DS100JA4000COMP
Enclosure
Fuse holder
Terminal Strip
Strain Relief
Mating Connector (Sockets)
Mating Connector (Pins)
FUS357001
TRS20007
EH5510043
CONA37S
CONA37P
8.0 ELECTRICAL PARTS LIST
Schematic ID
Description
Part Number
CON206151-1
CON1
Connector, 37 pins
CON2-CON3
CON4-CON5
CON6
Connector, 6 position
Connector, 2 position
Connector, 37 sockets
Fuse, 3 AMP, 3AG
CON640428-6
CON640428-2
CON206306-1
FUS3
F1
L1-L3
Plug 1
RY1-RY3
Choke, 6.2 Microhenery’s
Cord, 18 AWG, SJT
Relay, 120VAC, SPST
CHO4610
WIRC1318006BL
REL120A01MP
6
Pelco Manual C916M (11/90)
9.0 SCHEMATICS
Figure 3. AUX2000 Schematics
Pelco Manual C916M (11/90)
7
10.0 SPECIFICATIONS
MECHANICAL
Enclosure:
ULlistedgrayindustrialcontrolpanel
enclosure
Weatherproofing: Cover and connectors fully gasketed
Mounting Means: 6 - 0.31" (.79 cm) diameter holes
Dimensions:
Unit Weight:
11.31" H x 9.44" W x 4.32" D
(28.7 cm x 4.25 cm x 10.97 cm)
7 lbs (3.15 kg)
Shipping Weight: 9 lbs (36.45 kg)
ELECTRICAL
Input Voltage: 120 VAC
Power
Requirements: 360 VA
Power Cord:
18/3 AWG, listed SJT
Fuse Protection: 3 amp
Connectors:
AMP CPC type
Conductor
Requirements: Minimum 20 AWG
Cable Distance:
Wire
Maximum Distance Maximum Distance
Gauge
In Feet (meters) *
In Feet (meters) **
1,490 (454.2)
940 (286.5)
16
18
20
495 (150.9)
310 (94.5)
195 (59.4)
590 (179.8)
* One amp load for each auxiliary function and one
common neutral.
** One amp for each auxiliary function and one neutral
conductor for each auxiliary function.
8
Pelco Manual C916M (11/90)
NOTES
Pelco Manual C916M (11/90)
9
11.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
•
•
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),
and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 1990, Pelco. All rights reserved.
|