Maytag Range MGT8655X User Manual

30" (76.2 cm) Freestanding Gas Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
MGT8655X  
MGT8775X  
MGT8885X  
B*  
GAS SUPPLY REQUIREMENTS  
Gas supply line:  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range  
location. A smaller size pipe on longer runs may result in  
insufficient gas supply. With LP gas, piping or tubing size can  
be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine  
the size and materials used in the system.  
NOTE: Pipe-joint compounds that resist the action of LP gas  
®†  
must be used. Do not use TEFLON tape.  
C**  
Flexible metal appliance connector:  
If local codes permit, a new CSA design-certified, 4 to 5 ft  
(122 to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D.,  
flexible metal appliance connector may be used for connecting  
range to the gas supply line.  
A
D
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to  
the female pipe threads of the inlet to the appliance pressure  
regulator.  
E***  
Do not kink or damage the flexible metal tubing when moving  
the range.  
F
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve.  
This valve should be located in the same room but external to  
the range opening, such as an adjacent cabinet. It should be in a  
location that allows ease of opening and closing. Do not block  
access to shutoff valve. The valve is for turning on or shutting  
off gas to the range.  
A. 35³⁄₄" ¹⁄₈" (90.8 0.3 cm)  
cooktop height (minimum)  
with leveling legs screwed  
all the way in  
B. Model/serial/rating plates  
(located behind the control  
panel)*  
C. 47¹⁄₈" ¹⁄₈" (119.7 0.3 cm)  
overall height (minimum) with  
leveling legs screwed all the  
way in**  
D. 28¹⁄₂" ¹⁄₄" (72.4 0.6 cm)  
depth with handle  
B
E. 26¹⁄₈" to 27¼" ¹⁄₈"  
(66.4 0.3 cm)***  
F. 29¹⁵⁄₁₆" ¹⁄₁₆" (76.0 0.2 cm)  
width  
A
*Model/serial/rating plates may be rotated up from behind the  
control panel for viewing from the front of the range.  
**Range can be raised approximately 1" (2.5 cm) by adjusting  
the leveling legs.  
C
A. Gas supply line  
B. Shutoff valve openposition  
C. To range  
***Excludes handle. Dimension given is from wall to front of oven  
door and will vary based on electrical outlet receptacle  
installation.  
Type of Gas  
Natural gas:  
This range is design-certified by CSA International for use with  
Natural gas or, after proper conversion, for use with LP gas.  
ELECTRICAL REQUIREMENTS  
This range is factory set for use with Natural gas. See “Gas  
Conversions” section. The model/serial rating plate located  
behind the control panel has information on the types of gas  
that can be used. If the types of gas listed do not include the  
type of gas available, check with the local gas supplier.  
IMPORTANT: The range must be electrically grounded in accordance with local  
codes and ordinances, or in the absence of local codes, with the National Electrical  
Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.  
If codes permit and a separate ground wire is used, it is recommended that a  
qualified electrical installer determine that the ground path is adequate.  
LP gas conversion:  
Conversion must be done by a qualified service technician.  
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-  
No attempt shall be made to convert the appliance from the gas  
specified on the model/serial rating plate for use with a different  
gas without consulting the serving gas supplier. See “Gas  
Conversions” section.  
delay fuse or circuit breaker is also recommended. It is recommended that a  
separate circuit serving only this range be provided.  
Electronic ignition systems operate within wide voltage limits, but proper  
grounding and polarity are necessary. Check that the outlet provides 120-volt  
power and is correctly grounded.  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.  
Page 1 of 2  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10345639B  
12/21/10  
 

Laarsen Associates Swimming Pool Heater LG LD User Manual
Leica Camcorder Accessories FTA360 User Manual
Leviton Switch LE RZCZ User Manual
LG Electronics Washer WD 14110FDF User Manual
Life Fitness Elliptical Trainer CT85 0XXX 02 User Manual
Life Fitness Elliptical Trainer X35 01 User Manual
Lincoln Electric Welder 11079 User Manual
Makita Sander 900BL User Manual
Marantz CD Player DR4160 User Manual
Metra Electronics Automobile Accessories 99 7893 User Manual