Triton Le - System Version 1.0.3
Availability: May, 2002 Production
General – TRITON Le 76
[Improvement of function]
The Velocity Sensitivity scaling for the 76 key model has been improved.
Media Mode
[Bug Fix]
When using a CD-ROM (ISO9660 Format), if several .KSC files were located in
the same folder (directory), then occasionally the corresponding .KMP/.KSF files
would not load correctly. This has been fixed.
Triton Le - System Version 1.0.2
Availability: December, 2001 Production
MIDI
[Improvement of function]
The setting of Global P2.1 "MIDI Filter" Control Change has been improved to no
longer filter the reception of Channel Messages, Local Control On/Off,
All Note Off, Omni On/Off, Mono Mode On and Poly Mode On.
Arpeggiator
[Bug fix]
When using "Copy Arpeggiator" Utility on page P6.1 (Combination or Sequencer
mode), the settings of the Arpeggiator Run functions were not copied correctly.
This has been fixed.
Program mode
[Bug fix]
You cannot write to the ROM [G, g(d)] banks. However, a bug enabled this
operation, which would result in corrupting the ROM data. When the REC/WRITE
key is pressed, the "Update Program" dialog box will open automatically. If the
TRITON Le received a Program Change command– either via MIDI or from the
foot switch (set to Program Up/Down) – then a ROM bank could be selected
while this dialog box was open. Executing the UPDATE operation could corrupt
the ROM data. This has been fixed.
[Improvement of function]
Global P1.1 "Memory Protect".
When trying to load in a PCG file with the Memory Protect on, unnecessary
messages were displayed before the "Memory protected" message was shown.
These messages have been removed.
[Bug fix]
When a multisample having the same name as the volume label was saved to
the root directory using “SAVE ALL” or “Save Multisamples and Samples”, errors
would occur. This has been fixed.
[Bug fix]
Using the “Copy” utility on a directory containing more than 17 layers produced a
malfunction. This has been fixed.
END.
|