IR230 Infrared Receiver Specifications:
IR230
Installation Instructions v1.2
Peep-hole Infrared Receiver
Specifications
Infrared carrier frequency: 30-60kHz
Indoor reception range:
Nominal reception angle:
Maximum wire length:
30-40 feet (6-8 meters)
50 degrees off axis
1000’ (300m) or more with larger
Warning: To be installed and/or used in accordance with
appropriate electrical codes and regulations.
gauge wire
Introduction: Thank you for your purchase of a Knoll IR230
infrared receiver. This receiver features the ability to pick up a
remote control infrared signal and relay it on wires to another
location up to 1000’ (or more).
Wire requirements:
3 conductors, minimum 24-gauge
to 200’; 22-gauge up to 500’;
20-gauge to 1000’
Unregulated 12VDC, 40mA
0.6” x 2” (15mm x 50mm)
½” (12mm)
Power requirements:
Dimensions:
Cut out hole dimensions
Cord length
Features:
75” (2 meters)
Primarily designed to for mounting in panels, doors,
cabinets etc.
Will relay almost all remote control types (except som
B & O and Elite models).
Can be connected with almost any 3-conductor wire
including cat 5.
Requires very little power. Suggest using PS1202 12
VDC (200 mA) for up to 5 IR21s.
Up to 10 or IR230s, IR21s and other compatible mode
can be connected in a single system.
Brass and white color bezel supplied
Small and CFL and sunlight ready design
Requires 12VDC power supply, emitter(s) and IR54, or
IR55 connection block.
Warranty
Knoll Systems warrants its products sold in the USA and Canada by authorized
Knoll dealers to be free of defects in materials and workmanship. This warranty
extends for three full years from the date of purchase by the original consumer.
Any products returned to Knoll Systems and found to be defective by Knoll
Systems within the warranty period will be repaired or replaced at Knoll Systems
option, at no charge. Knoll Systems will not be responsible for the actual cost of
installation or removal of the product, nor for any incidental or consequential
damages. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you. This
warranty gives you specific legal rights. You may have additional legal rights
that vary from state-to-state.
Installation Tips
1. Follow all local electrical & building code requirements.
2. The IR230 is usually mounted in a panels, door, cabinet or
plate. It does not normally require a junction box. For easy
installation and to ensure reliability, it is suggested that a
PS1205 (500 mA) 12 VDC unregulated power supply, IR31
(single) or IR34 (dual) emitters and one of the following: IR54
(decora inwall style, 4 output) or IR55 (tabletop style, 4 output)
connection block, be used.
145 Tyee Drive Point Roberts, WA 98281
12140 Horseshoe Way, Richmond BC V7A 4V4
Telephone: (604) 272-4555, Fax: (604) 272-5595
Made in China Knoll Systems All Rights Reserved
3. Wires can be solid or stranded, shielded or unshielded with a
minimum of 28-gauge for runs under 200’, 22-gauge for runs
|