KitchenAid Ventilation Hood KIRD801V User Manual

®
30" (76.2 CM) and 36" (91.4 CM) Retractable Downdraft Vent System  
PRODUCT MODEL NUMBERS  
ELECTRICAL REQUIREMENTS  
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical  
cIrcuit is required. Use copper wire only.  
KIRD801V  
KIRD861V  
KIRD862V  
PRODUCT DIMENSIONS  
Interior-mounted blower motor model  
Top trim widths:  
Exterior-mounted blower motor model -  
used with Part Number KPEC992M  
30¹⁄₄" (76.8 cm) for 30" (76.2 cm) vent  
36¹⁄₄" (92.1 cm) for 36" (91.4 cm) vent  
13¹⁄₂" (34.3 cm)  
retractable  
vent height  
¹⁄₄" (0.6 cm)  
13" (33.0 cm)  
1¹⁄₂" (3.8 cm)  
³⁄₈" (0.95 cm)  
27" (68.6 cm) for 30" (76.2 cm) vent  
33" (83.8 cm) for 36" (91.4 cm) vent  
6¹⁄₂"  
(16.5 cm)  
Terminal box cover  
10" (25.4 cm)  
diameter  
vent collar  
28³⁄₄"  
(73.0 cm)  
6¹⁄₂"  
³⁄₄" (1.9 cm)  
(16.5 cm)  
13" (33.0 cm)  
13" (33.0 cm)  
³⁄₄"  
(1.9 cm)  
13" (33.0 cm)  
9¹⁄₄"  
(23.5 cm)  
6" (15.2 cm)  
diameter  
vent collar  
2¹⁄₈" (5.4 cm)  
CABINET DIMENSIONS  
Interior-mounted blower motor model  
Exterior-mounted blower motor model  
7⁵⁄₈" (19.4 cm)  
¹⁄₂" (12.7 mm)  
minimum  
A= ¹⁄₂" (12.7 mm)  
minimum  
23³⁄₄"  
(60.3 cm)  
21⁄₁₆"  
(54.1 cm)  
21⁄₁₆"  
(54.1 cm)  
All cutouts are  
for 6" (15.2 cm)  
diameter vent  
system.  
Locate power  
supply junction  
box at lower  
left hand  
Centerline of cooktop cutout  
Locate power  
rear corner  
supply junction  
box at lower  
left hand  
of the cabinet.  
rear corner  
of the cabinet.  
Page 1 of 3  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10187117  
11-06-08  
 
®
30" (76.2 CM) and 36" (91.4 CM) Retractable Downdraft Vent System  
VENTING REQUIREMENTS  
It is recommended that you use round vent instead of rectangular vent, especially  
if elbows are required. If rectangular vent is required, it should be transitioned to  
6" (15.2 cm) round vent as soon as possible.  
Example Vent System  
C
6 ft  
(1.8 m)  
To calculate the length of the system you need, add the equivalent feet (meters)  
for each vent piece used in the system.  
B
A
Maximum Length of Vent System  
2 ft (0.6 m)  
Vent  
Length  
6" (15.2 cm) round  
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)  
35 ft (8.9 m)  
35 ft (8.9 m)  
D
A. Blower motor  
B. Transition  
To calculate the length of the system you need, add the  
equivalent feet (meters) for each vent piece used in the system.  
C. 90° elbows  
D. 6" backdraft damper (supplied)  
Vent Piece  
6" (15.2 cm) Round  
IMPORTANT: Make sure there is proper clearance within the wall or  
45° elbow  
2.5 ft  
(0.8 m)  
floor before making exhaust vent cutouts.  
Use heavy (rigid) metal vent.  
Venting system must terminate to the outside.  
Do not terminate the vent system in an attic or other enclosed area.  
Do not use 4" (10.2 cm) laundry-type wall caps.  
Do not install 2 elbows together.  
90° elbow  
5.0 ft  
(1.5 m)  
Do not use plastic or metal foil vent.  
The length of vent system and number of elbows should be kept to a  
minimum to provide efficient performance.  
6" (15.2 cm)  
wall cap  
0.0 ft  
(0.0 m)  
Use no more than three 90° elbows  
Make sure there is a minimum of 24" (61 cm) of straight vent between  
the elbows if more than one elbow is used.  
Use clamps to seal all joints in the vent system.  
Use caulking tape to seal the exterior wall or floor opening around cap.  
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft  
to 6" (15.2 cm) transition  
(1.4 m)  
Do not cut joist or stud. If vent cutout falls over a joist or stud, a  
supporting frame must be constructed.  
Flexible metal vent is not recommended. If it is used, calculate each foot  
of flexible vent as 2 ft (0.6 m) of rigid metal vent. Flexible elbows count  
twice as much as standard elbows.  
6" (15.2 cm) to 3¹⁄₄" x 10"  
(8.3 cm x 25.4 cm) transition  
1 ft  
(0.3 m)  
Recommended vent system length:  
For either interior-mounted or exterior-mounted blower installations, the  
vent system length should not exceed the maximum lengths listed in the  
Maximum Length of Vent System chart.  
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft  
to 6" (15.2 cm) 90° elbow  
transition  
(1.5 m)  
6" (15.2 cm) to 3¹⁄₄" x 10"  
5.0 ft  
(8.3 cm x 25.4 cm) 90° elbow (1.5 m)  
transition  
Page 3 of 3  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10187117  
11-06-08  
 

Infinity Speaker Kappa Series User Manual
Insignia DVD Recorder NS 1DRVCR User Manual
Intelligent Motion Systems Computer Hardware UDAS 1001E User Manual
IOGear GPS Receiver GICe711S3W6 User Manual
Ironman Fitness Home Gym 530e User Manual
John Lewis Dishwasher JLBIDW 1201 User Manual
JVC Car Speaker KD A95BT User Manual
JVC Flat Panel Television 1203TNH II IM User Manual
Keys Fitness Treadmill CZE Plus User Manual
Kompernass Drill PTBM 350 13 User Manual