KitchenAid Microwave Oven KHHC209OS User Manual

®
Microwave Hood Combination  
CABINET OPENING DIMENSIONS  
PRODUCT MODEL NUMBERS  
A
B
KHHC209OS  
NOTE: The grounded 3 prong outlet  
must be inside the upper cabinet.  
Electrical: A 120-volt, 60-Hz, AC-only, 15- or  
20-amp electrical supply located in the upper  
cabinet as close as possible to the microwave  
oven hood. A time-delay fuse or circuit breaker  
and separate circuit is recommended.  
*33" (83.2 cm) is typical for 69"  
(175.3 cm) installation height. Exact  
dimension may vary depending on  
type of range/cooktop below.  
30"  
(76.2 cm)  
min.  
33"  
(83.2 cm)  
typical*  
12" (30.5 cm) min.  
13" (33.0 cm) max.  
OVERALL DIMENSIONS  
69" (175.3 cm) min.  
18¹⁄₄"  
(46.4 cm)  
29⁷⁄₈" (76.0 cm)  
15¹⁄₂"  
(39.4 cm)  
18¹⁄₄"  
(46.4 cm)  
A. 2" x 4" wall stud  
B. Grounded 3 prong outlet  
VENTING REQUIREMENTS  
Roof venting  
Wall venting  
roof cap  
Recommended vent length  
Use 3-1/4" x 10" or 6" vent. The total length of the vent system  
including straight vent, elbow, transitions, wall or roof caps  
must not exceed the equivalent of 140 feet of  
wall cap  
3-1/4" x 10" rectangular or 6" diameter round vent. For best  
performance, use no more than three 90° elbows. To calculate  
the length of system you need, add the equivalent feet for  
each vent piece used in the system. See examples below.  
3-1/4" x 10"  
through-the-wall  
3-1/4" x 10"  
through-the-roof  
3-1/4" x 10" vent system  
For wall or roof venting methods:  
Recommended standard fittings  
3-1/4" x 10"  
90° elbow  
If the wall exhaust method is chosen, be sure that  
there is proper clearance within the wall so the vent  
fits properly and the damper blade opens fully.  
wall cap  
6 ft.  
Wall and roof caps must have back-draft damper.  
We recommend:  
using rigid metal vent.  
2 ft.  
1 - 3-1/4" x 10"  
90° elbow  
= 25 ft.  
= 40 ft.  
3-1/4" x 10"  
90° elbow = 25 ft.  
3-1/4" x 10"  
to 6" = 5 ft.  
3-1/4" x 10"  
roof cap = 24 ft.  
that length of vent and number of elbows should  
be kept to a minimum to provide efficient  
performance.  
1 - wall cap  
8 feet straight  
Length of  
=
8 ft.  
that size of vent should be uniform.  
using duct tape to seal all joints in the vent  
system.  
using caulking compound to seal exterior wall or  
roof opening around cap.  
two elbows should not be installed together.  
3-1/4" x 10" system  
= 73 ft.  
6" vent system  
90° elbow  
3-1/4" x 10"  
90° flat  
3-1/4" x 10" 45° elbow  
90° elbows  
6 ft.  
6" = 10 ft.  
wall cap  
5 ft.  
= 20 ft.  
= 40 ft.  
8 ft.  
wall cap =  
40 ft.  
6" = 5 ft.  
elbow= 10 ft.  
If the existing vent is round, a rectangular-  
to-round adapter must be used and a  
rectangular 3" extension vent between the  
damper assembly and the adapter must be  
installed to prevent sticking of the exhaust  
damper.  
We do NOT recommend:  
flexible metal vent.  
1 - transition  
2 - 90° elbows  
1 - wall cap  
=
2 ft.  
NOTE: If flexible metal vent must be used, calculate  
each foot of flexible metal vent as two feet of rigid  
metal vent. Flexible metal elbows count twice as  
much as standard elbows.  
8 feet straight  
=
Length of 6" system = 73 ft.  
transition  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8206590  
04-17-07  
 

Indesit Dishwasher IDL 500 User Manual
Intex Recreation Swimming Pool 88PO User Manual
Johnson Hardware Door 1500 Series User Manual
Joovy Stroller 320 User Manual
JVC CRT Television AV 30W476 User Manual
JVC Stereo Receiver KD S737R User Manual
JVC Stereo System 0205NYMCREBET User Manual
Kenmore Vacuum Cleaner 11629914 User Manual
KitchenAid Clothes Dryer 86 User Manual
Kompernass CD Player KH 7000 User Manual