SIGNALING
U
L
LISTED
Sm o ke Ala rm
User’s Guide
Model: i9030, i9040, i9040RV i9050, i9060,
i9060RV a n d i9080
i9040
a n d
i9040RV
i9030
i9060
a n d
i9050
i9080
i9060RV
• 9 Volt Battery Operated
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide w hich should be saved for future reference and
passed on to any subsequent ow ner.
Manual P/N 820-1493 Rev. A
Pro d u ct Sp e cifica t io n s
1. Re co m m e n d e d Lo ca t io n s fo r Sm o ke Ala rm s
This alarm detects products of combustion using the ionization tech-
nique. It contains 0.9 microcurie of Americium 241, a radioactive materi-
al (see section 9). Distributed under U.S. NRC License No. 32-23858-01E.
Manufactured in compliance with U.S. NRC safety criteria in 10 CFR
32.27. The purchaser is exempt from any regulatory requirements. Do
not try to repair the smoke alarm yourself. Refer to the instructions in
section 12 for service.
•
Locate the first alarm in the immediate
area of the sleeping rooms. Try to monitor
the exit path as the sleeping rooms are
usually farthest from the exit. If more than
one sleeping area exists, locate additional
alarms in each sleeping area (See figure 3).
•
•
Locate additional alarms to monitor any
stairway as stairways act like chimneys for
smoke and heat.
LOSS OF POWER TO THE ALARM WILL RENDER THIS ALARM
INOPERATIVE.
FIGURE 1
Locate at least one alarm on every floor
level.
•
•
Locate an alarm in every sleeping room.
Co n t e n t s o f Th is Use r’s Gu id e
Locate an alarm in every room where elec-
trical appliances are operated (i.e. portable
heaters or humidifiers).
1. Recommended Locations for Smoke Alarms
2. Locations to avoid
•
•
Locate an alarm in every room where
someone sleeps with the door closed. The
closed door may prevent an alarm not
located in that room from waking the
3. Installation Instructions
4. Operation and testing
5. Nuisance Alarms
sleeper.
FIGURE2
6. Maintenance
Smoke, heat, and combustion products
rise to the ceiling and spread horizontally.
Mounting the smoke alarm on the ceiling
in the center of the room places it closest
to all points in the room. Ceiling mount-
ing is preferred in ordinary residential con-
struction.
7. Limitations of Smoke Alarms
8. Good Safety Habits
9. NRC Information
10. NFPA Protection Standard 72
11. California State Fire Marshal Required Information
12. Service and Warranty
•
For mobile home installation, select loca-
tions carefully to avoid thermal barriers
that may form at the ceiling. For more
details, see MOBILE HOME INSTALLATION
below.
•
•
When mounting an alarm on the ceiling,
locate it at a minimum of 4” (10 cm) from
the side wall (see figure 1).
FIGURE 3
ANYWHERE ALONG
THIS BOLD SURFACE
When mounting the alarm on the wall, use
an inside wall with the top edge of the
alarm at a minimum of 4” (10 cm) and a
maximum of 12” (30.5 cm) below the ceil-
ing (see figure 1).
12”
(300mm)
FIGURE 4
1. Re co m m e n d e d Lo ca t io n s fo r Sm o ke Ala rm s
2. Lo ca t io n s To Avo id
•
In the garage. Products of combustion are present when you start
your automobile.
•
•
Put smoke alarms at both ends of a hallway or large room if the hall-
way or room is more than 30 ft (9.1 m) long. For large rooms, one
smoke alarm is recommended for every 500 square feet of floor
space.
•
•
Less than 4” (10cm) from the peak of an “A” frame type ceiling.
In an area where the temperature may fall below 40ºF or rise above
100ºF, such as garages and unfinished attics; this should also include
electrical boxes exposed to these environments.
In homes that are not well insulated, extreme heat or cold can be
transferred from the outside to the inside through poorly insulated
walls and roof. This may create a thermal barrier which can prevent
the smoke from reaching an alarm mounted on the ceiling. If you are
not sure about the insulation in your home, or if you notice that the
outer walls and ceiling are either hot or cold, install the alarm on an
inside wall. In such homes, install the smoke alarm with the top edge
of the alarm at a minimum of 4” (10 cm) and a maximum of 12”
(30.5 cm) below the ceiling (see figure 1).
•
In dusty areas. Dust particles may cause nuisance alarm or failure to
alarm.
•
•
•
In very humid areas. Moisture or steam can cause nuisance alarms.
In insect-infested areas.
Smoke alarms should not be installed within 3 ft (.9m) of the following:
the door to a kitchen, the door to a bathroom containing a tub or
shower, forced air supply ducts used for heating or cooling, ceiling or
whole house ventilating fans, or other high air flow areas.
•
•
Install Smoke Alarms on sloped, peaked or cathedral ceilings at or
within 3ft (0.9m) of the highest point (measured horizontally). NFPA
72 states: “Smoke alarms in rooms with ceiling slopes greater than 1
ft in 8 ft (.3m in 2.4 m) horizontally shall be located on the high side
of the room.” NFPA 72 states: “A row of detectors shall be spaced
and located within 3 ft (0.9m) of the peak of the ceiling measured
horizontally” (see figure 2).
•
Kitchens. Normal cooking may cause nuisance alarms. If a kitchen
alarm is desired, it should have an alarm silence feature or be a photo-
electric type.
•
•
Near fluorescent lights. Electronic “noise” may cause nuisance alarms.
Smoke alarms are not to be used with detector guards unless the
combination (alarm and guard) has been evaluated and found suitable
for that purpose.
Install Smoke Alarms on tray-shaped ceilings (coffered ceilings) on the
highest portion of the ceiling or on the sloped portion of the ceiling
within 12” (305mm) vertically down from the highest point (see figure
4).
Mobile Home Installation
Modern mobile homes have been designed and built to be energy effi-
cient. Install smoke alarms as recommended above (refer to RECOM-
MENDED LOCATIONS and Figures 1 and 2). In older mobile homes that
are not well insulated compared to present standards, extreme heat or
cold can be transferred from the outside to the inside through poorly
insulated walls and roof. This may create a thermal barrier which can
prevent the smoke from reaching an alarm mounted on the ceiling. In
such units, install the smoke alarm on an inside wall with the top edge
of the alarm at a minimum of 4” (10cm) and a maximum of 12”
(30.5cm) below the ceiling (see figure 1).
If you are not sure about the insulation in your mobile home, or if you
notice that the outer walls and ceiling are either hot or cold, install the
alarm on an inside wall. For minimum protection, install at least one
alarm close to the sleeping rooms. For additional protection, see SINGLE
FLOOR PLAN in figure 2.
WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER RV
OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE, BEFORE
EACH TRIP AND AT LEAST ONCE A WEEK DURING USE.
3. In st a lla t io n In st ru ct io n s
3. In st a lla t io n In st ru ct io n s
MOUNTING INSTRUCTIONS
CAUTION: This unit is sealed. The cover is not removable!
O
1. Remove the mounting plate from the back of the alarm by holding the
mounting plate and twisting the alarm in the direction indicated by the
“OFF” arrow on the alarm cover.
A
A
2. To insure aesthetic alignment of the alarm with the hallway or wall, the
“A” line on the mounting plate should be parallel with the hallway when
ceiling mounting or horizontal when wall mounting.
mounting
i9030 mounting
bracket for all
3. After selecting the proper smoke alarm location as described in section 1,
attach the mounting plate to the ceiling as shown in figure 5 and figure
5A. For wall mounting see figure 6 and figure 6A. Place mounting plate
on the wall as described in the mounting illustrations. Use the screws
and anchors provided to secure the mounting plate (use 3/16” drill bit for
anchor holes).
bracket shown
other models
FIGURE 5
FIGURE 5A
FIGURE 6
The “A” line should be hori-
zontal and the “UP FOR
WALL MOUNTING” arrow
must be pointing up.
4. Battery installation instructions are provided on the inside of the battery
door. To ensure proper installation of the smoke alarm battery, follow
the instructions.
5. When installing the battery, press the battery reminder finger down into
the battery compartment and install the battery (see figure 7 and figure
7A for the i9080 alarm).
5º
CAUTION! IF THE BATTERY REMINDER FINGER IS NOT HELD DOWN IN
THE BATTERY COMPARTMENT BY THE BATTERY, THE BATTERY DOOR
WILL NOT CLOSE AND THE UNIT WILL NOT ATTACH TO THE MOUNT-
ING BRACKET. NOTE: THE I9030 AND I9040 DO NOT HAVE A BATTERY
DOOR.
FIGURE 6A
FIGURE 7
FIGURE 7A
When wall mounting,
mount flat side to the
wall and rotate mount-
ing plate approximately
5º to the right as shown.
6. Alignment marks are provided on the edge of the trim plate and the
alarm. After installing the mounting plate, place the alarm on the
mounting plate with the alignment marks lined up. Twist the alarm in the
direction indicated by the “ON” arrow on the alarm cover (see figure 8)
until it locks in place.
7. USING TAMPER RESIST LOCKING PIN (all models except i9040 and
i9040RV): To make your smoke alarm tamper resistant, a locking pin has
been provided in the bag with the screws and anchors. Using this pin will
help deter children and others from removing the alarm from the mount-
ing plate. To use the pin, insert it into the hole in the side of the alarm
after the alarm has been installed on the mounting plate (see figure 9).
Alignment marks
Remove
Install
NOTE: THE TAMPER RESIST PIN WILL HAVE TO BE REMOVED IN
ORDER TO CHANGE THE BATTERIES. USE LONG NOSE PLIERS TO PULL
THE PIN OUT OF THE HOLE. IT IS NOW POSSIBLE TO REMOVE THE
ALARM FROM THE MOUNTING PLATE.
8. After installation, test your alarm by depressing and holding down the
test button for at least 5 seconds. This should sound the alarm.
FIGURE 8
FIGURE 9
4. Op e ra t io n a n d Te st in g
5. Nu isa n ce Ala rm s
OPERATION: The smoke alarm is operating once a fresh battery is
installed and testing is complete. When products of combustion are
sensed, the unit sounds a loud 85db pulsating alarm until the air is
cleared.
Smoke alarms are designed to minimize nuisance alarms. Cigarette
smoke will not normally set off the alarm, unless the smoke is blown
directly into the alarm. Combustion particles from cooking may set off
the alarm if the alarm is located close to the cooking area. Large quanti-
ties of combustible particles are generated from spills or when broiling.
Using the fan on a range hood which vents to the outside (non-recircu-
lating type) will also help remove these combustible products from the
kitchen. If the alarm does sound, check for fires first. If a fire is discov-
ered, get out and call the fire department. If no fire is present, check to
see if one of the reasons listed in section 2 may have caused the alarm.
HUSH CONTROL: The “HUSH” feature has the capability of temporarily
desensitizing the alarm circuit for approximately 8 minutes. This feature
is to be used only when a known alarm condition, such as smoke from
cooking, activates the alarm. Models i9060, i9060RV and i9080 are
desensitized by pushing the “HUSH” button on the smoke alarm cover.
Models i9030, i9040, i9040RV and i9050 are desensitized by pushing
the TEST/HUSH button on the cover. If the smoke is not too dense, the
alarm will silence immediately and the Red LED will flash once every 10
seconds for approximately 8 minutes. This indicates that the alarm is in a
temporarily desensitized condition. The smoke alarm will automatically
reset after approximately 8 minutes and sound the alarm if particles of
combustion are still present. The “HUSH” feature can be used repeated-
ly until the air has been cleared of the condition causing the alarm.
6. Ma in t e n a n ce
BATTERY REPLACEMENT
Note: Replacement batteries are available where you purchased your
alarm.
If tamper resist pin has been used, refer to TAMPER RESIST LOCKING PIN
in section 3 for removal instructions. To replace the battery, remove the
alarm from the mounting plate by rotating the alarm in the direction of
the “OFF” arrow on the cover (see figure 8).
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEA-
TURE AND SOUND A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY
THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION
EXISTS.
i9030, i9040, i9050, i9060 and i9080 Smoke Alarms are powered by a
9V carbon zinc battery (alkaline and lithium batteries may also be used).
A fresh battery should last for one year under normal operating condi-
tions. This alarm has a low battery monitor circuit which will cause the
alarm to “chirp” Approximately every 30 - 40 seconds for a minimum
of seven (7) days when the battery gets low. Replace the battery when
this condition occurs.
FLASHING LED LIGHT: This smoke alarm is equipped with a flashing
red indicator light. The light is located under the test button and will
flash every 40 seconds to indicate that the smoke alarm is receiving
power.
TESTING: Test by pushing the test button on the cover and holding it
down for a minimum of 5 seconds. This will sound the alarm if the elec-
tronic circuitry, horn, and battery are working. If no alarm sounds, the
unit has defective batteries or other failure. DO NOT use an open flame
to test your alarm, you could damage the alarm or ignite combustible
materials and start a structure fire.
NOTE: ANY STATEMENTS REFERRING TO A BATTERY, APPLIES TO
BOTH BATTERIES USED WITH THE i9080
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM
BATTERY REPLACEMENT.
Carbon-zinc type:
Alkaline type:
EVEREADY 1222; GOLD PEAK 1604P OR 1604S
TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION.
ENERGIZER 522; DURACELL MN1604, MX1604;
GOLD PEAK 1604A; PANASONIC 6AM6, 6AM-6,
6AM-6PI, 6AM6X, AND 6LR61(GA)
Erratic or low sound coming from your alarm may indicate a defective
alarm, and it should be returned for service (see section 12).
NOTE: WEEKLY TESTING IS REQUIRED.
Lithium type:
ULTRALIFE U9VL-J
Models i9040RV and i9060RV are powered by a 9V alkaline battery.
A
fresh battery should last for one year under normal operating conditions.
This alarm has a low battery monitor circuit which will cause the alarm
to “chirp” approximately every 30 - 40 seconds for a minimum of seven
(7) days when the battery gets low. Replace the battery when this condi-
tion occurs.
6. Ma in t e n a n ce
6. Ma in t e n a n ce
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR i9040RV AND
i9060RV SMOKE ALARM BATTERY REPLACEMENT:
lamp holder assembly. Slide the old lamp out of the lamp holder and
replace it with a new lamp. Replace with the correct lamp type: Vanco
#FTB 6 which is available at most radio/tv repair stores.
Alkaline type:
ENERGIZER 522; DURACELL MN1604, MX1604;
PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X,
AND 6LR61(GA)
Reinstall the lamp holder. It will snap easily into the base. Put working
batteries back in the alarm and remount the alarm on its mounting
bracket.
NOTE: WEEKLY TESTING IS REQUIRED.
CAUTION: Use only the lamp specified. Use of a different lamp
may have a detrimental effect on the smoke alarm or the safety
light operation.
WARNING! USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFER-
ENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE
SMOKE ALARM.
NOTE: The safety light is not intended to satisfy the requirements
for approved illumination under various local codes. Very thick
and/or dense smoke may obscure the light.
CLEANING YOUR ALARM
YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR
To clean your alarm, remove it from the mounting bracket as outlined in
the beginning of this section. You can clean the interior of your alarm
7. Lim it a t io n s o f Sm o ke Ala rm s
WARNING: PLEASE READ CAREFULLY AND THOROUGHLY
(sensing chamber) by using compressed air or a vacuum cleaner hose
and blowing or vacuuming through the openings around the perimeter
of the alarm. The outside of the alarm can be wiped with a damp cloth.
•
NFPA 72 states: Fire-warning equipment for residential occupancies
are capable of protecting about half of the occupants in potentially
fatal fires. Victims are often intimate with the fire, too old or too
young, or physically or mentally impaired such that they cannot
escape even when warned early enough that escape should be possi-
ble. For these people, other strategies such as protection-in-place or
assisted escape or rescue would be necessary.
After cleaning, reinstall your alarm and test your alarm by using the test
button. If cleaning does not restore the alarm to normal operation the
alarm should be replaced.
SAFETY LIGHT
MODEL i9080
•
Smoke alarms are devices that can provide early warning of possible
fires at a reasonable cost; however, alarms have sensing limitations.
Ionization sensing alarms may detect invisible fire particles (associated
with fast flaming fires) sooner than photoelectric alarms. Photoelectric
sensing alarms may detect visible fire particles (associated with slow
smoldering fires) sooner than ionization alarms. Home fires develop in
different ways and are often unpredictable. For maximum protection,
Kidde recommends that both Ionization and Photoelectric alarms be
installed.
NOTE: If the safety light appears dim during regular testing, replace
both batteries immediately. Use only the following 9 volt batteries for
powering the safety light:
Alkaline Type
Energizer 522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI, 6AM6X and
6LR61 (GA)
•
•
A battery powered alarm must have a battery of the specified type, in
good condition and installed properly.
The safety light has a 6.3 V 250mA fuse lamp with an average life of 50
hours. If the safety light fails to operate with a fresh alkaline battery,
then replace the lamp. To replace the lamp, remove the alarm from the
mounting bracket by rotating the alarm in the direction of the “OFF”
arrow on the cover (See Figure 7, and Alarm Tamper Resist Feature sec-
tion if this feature has been activated).
AC powered alarms (without battery backup) will not operate if the
AC power has been cut off, such as by an electrical fire or an open
fuse.
•
•
Smoke alarms must be tested regularly to make sure the batteries and
the alarm circuits are in good operating condition.
Smoke alarms cannot provide an alarm if smoke does not reach the
alarm. Therefore, smoke alarms may not sense fires starting in chim-
neys, walls, on roofs, on the other side of a closed door or on a differ-
ent floor.
Open the battery door and remove both batteries from the unit. Grip
the lamp holder handle with your thumb and finger and pull out the
7. Lim it a t io n s o f Sm o ke Ala rm s
8. Go o d Sa fe t y Ha b it s
- Fires where the victim is intimate with a flaming initiated fire; for
example, when a person's clothes catch fire while cooking.
•
•
If the alarm is located outside the sleeping room or on a different
floor, it may not wake up a sound sleeper.
- Fires where the smoke is prevented from reaching the detector due
to a closed door or other obstruction.
The use of alcohol or drugs may also impair one’s ability to hear the
smoke alarm. For maximum protection, a smoke alarm should be
installed in each sleeping area on every level of a home.
- Incendiary fires where the fire grows so rapidly that an occupant's
egress is blocked even with properly located detectors
•
Although smoke alarms can help save lives by providing an early
warning of a fire, they are not a substitute for an insurance policy.
Home owners and renters should have adequate insurance to protect
their lives and property.
9. NRC In fo rm a t io n
Ionization type smoke alarms use a very small amount of a radioactive ele-
ment in the sensing chamber to enable detection of visible and invisible
combustion products. The radioactive element is safely contained in the
chamber and requires no adjustments or maintenance. This smoke alarm
meets or exceeds all government standards. It is manufactured and distrib-
uted under license from the U.S. Nuclear Regulatory Commission.
8. Go o d Sa fe t y Ha b it s
DEVELOP AND PRACTICE A PLAN OF ESCAPE
•
Make a floor plan indicating all doors and windows and at least two
(2) escape routes from each room. Second story windows may need a
rope or chain ladder.
10. NFPA Re q u ire d Pro t e ct io n
•
•
•
•
Have a family meeting and discuss your escape plan, showing every-
one what to do in case of fire.
The National Fire Protection Association’s Standard 72 provides the following
information:
Determine a place outside your home where you all can meet if a fire
occurs.
Smoke Detection - Where required by applicable laws, codes, or standards
for a specific type of occupancy, approved single- and multiple-station
smoke alarms shall be installed as follows:
Familiarize everyone with the sound of the smoke alarm and train
them to leave your home when they hear it
(1) In all sleeping rooms and guest rooms
Practice a fire drill at least every six months, including fire drills at
night. Ensure that small children hear the alarm and wake when it
sounds. They must wake up in order to execute the escape plan.
Practice allows all occupants to test your plan before an emergency.
You may not be able to reach your children. It is important they know
what to do.
(2) Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft)
of any door to a sleeping room, the distance measured along a path of travel
(3) On every level of a dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small facility),
including basements and excluding crawl spaces and unfinished attics
•
Install and maintain fire extinguishers on every level of the home and
in the kitchen, basement and garage. Know how to use a fire extin-
guisher prior to an emergency.
(5) In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy (small facility)
• Current studies have shown smoke alarms may not awaken all sleep-
ing individuals, and that it is the responsibility of individuals in the
household that are capable of assisting others to provide assistance to
those who may not be awakened by the alarm sound, or to those
who may be incapable of safely evacuating the area unassisted.
Are More Smoke Alarms Desirable? The required number of smoke alarms
might not provide reliable early warning protection for those areas separated
by a door from the areas protected by the required smoke alarms. For this
reason, the use of additional smoke alarms for those areas for increased pro-
tection is recommended. The additional areas include the basement, bed-
rooms, dining room, furnace room, utility room, and hallways not protected
by the required smoke alarms. The installation of smoke alarms in kitchens,
attics (finished or unfinished), or garages is not normally recommended,
because these locations occasionally experience conditions that can result in
improper operation.
• There are situations where a smoke alarm may not be effective to pro-
tect against fire as noted by the NFPA and UL. For instance:
- Smoking in bed.
- Leaving children unsupervised.
- Cleaning with flammable liquids, such as gasoline.
11. CAUTION (AS REQUIRED BY THE CALIFORNIA
STATE FIRE MARSHAL)
12. Se rvice a n d Wa rra n t y
If after reviewing this manual you feel that your smoke alarm is defective
in any way, do not tamper with the unit.
Ionization type smoke alarms use a very small amount of a radioac-
tive element in the sensing chamber to enable detection of visible
and invisible combustion products. The radioactive element is safely
contained in the chamber and requires no adjustments or mainte-
nance. This smoke alarm meets or exceeds all government stan-
dards. It is manufactured and distributed under license from the U.S.
Nuclear Regulatory Commission.
Return for servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane,
NC 27302. 800-880-6788 (See Warranty for in-warranty returns)
LIMITED WARRANTY
Kidde warrants to the original purchaser that the enclosed smoke alarm will
be free from defects in material and workmanship or design under normal
use and service for a period of three (3) years for i9030, i9040 and
i9040RV smoke alarms and ten (10) years for the i9050, i9060,
i9060RV, and i9080 smoke alarms from the date of purchase. The obli-
gation of Kidde under this warranty is limited to repairing or replacing the
smoke alarm or any part which we find to be defective in material, work-
manship or design, free of charge to the customer, upon sending the
smoke alarm with proof of date of purchase, postage and return postage
prepaid, to Warranty Service Department, Kidde, 1016 Corporate Park Dr.,
Mebane, NC 27302.
This warranty shall not apply to the smoke alarm if it has been damaged,
modified, abused or altered after the date of purchase or if it fails to oper-
ate due to improper maintenance or inadequate AC or DC electrical power.
THE LIABILITY OF KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPO-
RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER
THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE
EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND, IN NO
CASE, SHALL KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORA-
TIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING
FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR
DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.
Since some states do not allow limitations on the duration of an implied
warranty or do not allow the exclusion or limitation of incidental or conse-
quential damages, the above limitations or exclusions may not apply to
you. While this warranty gives you specific legal rights, you may also have
other rights which vary from state to state.
The above warranty may not be altered except in writing signed by both
parties hereto.
QUESTIONS OR FOR MORE INFORMATION
Call our Consumer Hotline at 1-800-880-6788 or contact
us at our website at w w w.kidde.com
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302
|