FL-10
Standard Features
• Water usage — 6.5 gallons per cycle
• 12 cycles per hour
• Construction - 12 & 14 gauge
stainless steel
• Operational and cleanability features
• Fully automatic cycle - 260 seconds
• Incoming water pressure regulator
- High pressure, all stainless steel
wash arms
- 28 3/4” wide x 30 1/2” high door
opening
- Double filtration system
- Externally mounted spray down
hose with spray gun nozzle
• Internally mounted electric booster
heater
- Capable of minimum 60°F temper-
ature rise for required 180°F
minimum sanitizing rinse temperature
• One (1) 9 KW Heating Element in a
9 1/2 gallon rinse tank
- Waterproof LED ditigal gauges
- Three wash cycles
• Two (2) Rotating Wash Arms -
1 upper & 1 lower
• Installation features
- Stainless steel control panel - easily
accessible
- Adjustable bullet feet
- Detergent/rinse additive signal
connection fuse box
• Stationary Rinse Nozzles -
Top & Bottom
• 30 Gallon Wash Tank
• Electromechanical controls
- Safety door switch
- Temperature control thermostat
and low water protection
Power/Connections
Electrical Rating
Wash Pump Motor Horsepower
Performance/Capacities
7.5
Full Load Amps
Electric
208V
230V 460V
Operating Capacity
Frame Dimensions (Inches)
71.0
46.0
22.0
46.0
65.2
42.6
20.0
42.6
33.6
22.3
11.0
22.3
Racks per Hour
12
Width
32
Steam Injectors
Steam Coils
Gas
Operating Cycle (Seconds)
Light
Depth
Height
44 (46 gas)
84 1/2
Gas Requirements
Gas Connection (NPT)
Natural Gas (Inches-water column)
Minimum inlet
Wash Time
180
20
1/2
Height (door open)
Electric
Dwell Time
103 1/2
106
Rinse Time
60
6.0
3 1/2
Gas
Total Cycle
260
Main Manifold
BTU
36,000
Wall Clearanse (Minimum)
16
Medium
Propane (Inches-water column)
Minimum inlet
Main Manifold
BTU
3” Stainless steel chimney on back of machine
Wash Time
Dwell Time
Rinse Time
Total Cycle
300
20
Wall Clearance
11.0
6.0
36,000
(Control Panel Side)
36 Wall
12
60
Clearance (Back)
380
Shipping Weight (Lbs.)
950
Steam Requirements
Steam connection (NPT)
Injectors (Lbs per hour)
Coils (Lbs per hour)
Heavy
3/4
15
33
Wash Time
Dwell Time
Rinse Time
Total Cycle
420
20
Shipping Size (Inches)
Width
Depth
Height
42
60
90
60
Water Requirements
Inlet Temperature (Minimum)
Gallons per Hour
500
140°F
78
6.5
1/2
1 1/2
15-25
Operating Temperatures
Wash — °F (Minimum)
Rinse — °F (Minimum)
Gallons per Rack
150
180
Waterline Size IPS (Minimum) (Inches)
Drainline Size IPS (Minimum) (Inches)
Flow Pressure (PSI)
|