HDTV ENCODER
INSTRUCTIONS
DM-JV600U
POWER
ON
OFF
For Customer Use:
Enter below the Serial No. which is
located on the rear of cabinet. Retain
this information for future reference.
Model No.
Serial No.
DM-JV600U
Thank you for purchasing this JVC product.
Before operating this unit, please read the instructions
carefully to ensure the best possible performance.
This instruction book is made from 100% recycle paper.
LST0159-001C
SAFETY PRECAUTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION
RISQUE D’ELECTROCUTION
NE PAS OUVRIR
ATTENTION: POUR EVITER TOUT RISQUE D’ELECTROCUTION
NE PAS OUVRIR LE BOITER.
AUCUNE PIECE INTERIEURE N’EST
A REGLER PAR L’UTILISATEUR.
SE REFERER A UN AGENT QUALIFIE EN CAS DE PROBLEME.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
Lesymboledel’éclairàl’intérieurd’untriangleéquilatéralest
destiné à alerter l’utilisateur sur la présence d’une “tension
dangereuse” non isolée dans le boîtier du produit. Cette
tension est suffisante pour provoquer l’électrocution de
personnes.
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
Le point d’exclamation à l’intérieur d’un triangle équilatéral
estdestinéàalerterl’utilisateursurlaprésenced’opérations
d’entretien importantes au sujet desquelles des
renseignements se trouvent dans le manuel d’instructions.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
*Ces symboles ne sont utilisés qu’aux Etats-Unis.
WARNING:
AVERTISSEMENT:
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
POUR EVITER LES RISQUES D’INCENDIE OU
D’ELECTROCUTION, NE PAS EXPOSER
L’APPAREIL A L’HUMIDITE OU A LA PLUIE.
This unit should be used with 120 V AC only.
CAUTION:
To prevent electric shocks and fire hazards, DO
NOT use any other power source.
Ce magnétoscope ne doit être utilisé que sur
du courant alternatif en 120 V.
ATTENTION:
Afin d’éviter tout resque d’incendie ou
d’électrocution, ne pas utiliser d’autres
sources d’alimentation électrique.
NOTE:
The rating plate (serial number plate) is on the rear of the unit.
INFORMATION for USA
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his own expense.
REMARQUE:
La plaque d’identification (numéro de série) se trouve
sur le panneau arrière de l’appareil.
WARNING:
The battery used in the DM-JV600U must be replaced
by a JVC authorized service dealer only.
CAUTION
CAUTION
CHANGES OR MODIFICATIONS NOT APPROVED BY
JVC COULD VOID USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
Use of controls or adjustments or performance of proce-
dures other than those specified herein may result in haz-
ardous radiation exposure.
THIS DEVICE COMPLIES WITH PART 15 OF THE
FCC RULES. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE
MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFER-
ENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
Note
Place a cover on the terminal not in use.
Static may cause a malfunction or failure of the unit.
INFORMATION for Canada
This Class A digital apparatus meets all requirements of
the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les
exigences du Reglement sur le matériel brouilleur de
Canada.
3
Main Features
Encoded to MPEG-2(ISO/IEC13818-2)
Thank you for purchasing this
HDTV ENCODER DM-JV600U.
Input SMPTE292M(1080i/720p) standard HDTV digital se-
rial video signal, encode it to MPEG-2(ISO/IEC13818-2)
and output as DVB-ASI TS(Transport Stream).
Supports SDI embedded Audio signal 2 channels
Encodes SMPTE299M standard SDI embedded Audio sig-
nal 2 channels to MPEG-1Layer 2 (ISO/IEC11172-3) and
output as TS format.
Dolby™ Digital (AC-3) pass through Compli-
ance
When Dolby™ Digital bitstream is applied to [AES/EBU] ter-
minal, TS Format output could be obtained as this equip-
ment is Dolby™ Digital (AC-3) 1-5.1 channel pass through
compliant.
In addition, when PCM signal is applied to [AES/EBU] termi-
nal, it is possible to encode with MPEG-1 Layer 2.
Equipped with RS-232C terminal
Each feature can be set or operated on the front panel with
FL display. Besides, this unit can be remote-controlled
through the 9-pin connector on the rear panel.
If should be noted that it may be unlawful to re-record
pre-recorded tapes, records, or discs without the con-
sent of the owner of copyright in the sound or video re-
cording, broadcast or cable program and in any literary,
dramatic musical, or artistic work embodied therein.
1U EIA size can be mounted to the rack
Owing to the compact size design, it can be mounted to the
EIA rack.
3-2 Pull down feature
Prior to important video/ audio recording, always perform
a test recording to confirm that video/ audio is properly
recorded.
By converting to the SMPTE292M (1080i/720p) standard
HDTV digital serial video signal, input movie film image that
is 24 frame per one second can also be compressed to
high quality using 3-2 Pull down feature.
Please note that we will not provide compensation for
contents of video/ audio recording due to improper video/
audio recording caused by defects when using this equip-
ment.
Equipped with ASI output terminal
Video recording is possible by connecting to D-VHS digital
video recorder from JVC that is equipped with ASI input ter-
minal.
Dolby is a trademark of Dolby Laboratories.
4
Table of Contents
Main Features ...................................... 4
Table of Contents................................. 5
Precautions .......................................... 6
Introduction
ODUC
Front Panel........................................... 7
Rear Panel ........................................... 8
Names and Functions
I
Connecting ........................................... 9
Mounting to a Rack ............................ 10
Preparation
Menu setting
Basic operation
Menu Flow Chart................................ 11
Menu Setting ...................................... 12
How to Change Menu Setting ............ 16
Restoring the Default Menu
Setting Value...................................... 17
Starting the Encoding......................... 18
Checking Operation Status ................ 20
Checking Error Log ............................ 21
Using the Administration Menu............ 22
Error Log ............................................ 24
Setting the 3-2 Pulldown .................... 26
Specifications ..................................... 27
Others
5
Precautions
Maintenance and operating environment
Transportation
ⅥDo not store or use this equipment in the following envi-
ronments. This will cause malfunctioning and damage.
Ⅵ Turn off the power and unplug the power cord from AC
outlet before transportation.
This may cause damage to power cord, fire or electrical
shock.
• Locations beyond the allowable operating temperature
range of 5 °C and 40 °C.
Ⅵ When moving or carrying the main unit, do no hold it
by the front panel as this can easily be detached by
pulling it toward you.
If moving or carrying the main unit while holding it by the
front panel, the main unit might be caused to fall as a
result of the front panel becoming detached. Such an in-
cident may cause unexpected injury or a malfunction of
the main unit.
• Locations beyond the allowable operating humidity
level of 30 % and 80 %.
•
Near equipment that produces strong magnetic fields, such
as transformers or motors.
• Near equipment that emits radio waves, such as trans-
ceivers and mobile phones.
• Locations with excessive dust and sand.
• Locations that are subject to excessive vibration.
• Locations prone to condensation.
Saving Energy
• Locations that emit radiation, X-rays or corrosive gases.
Ⅵ Turn off the power to save energy when the equipment is
not to be used for extensive periods of time.
Handling
ⅥDo not stack up the equipment to prevent temperature
within from rising.
ⅥDo not stand this equipment vertically during use.
ⅥHandle this equipment with care. Do not subject it to
physical shock.
ⅥDo not place heavy objects or ride on this equipment.
Placing heavy object such as TV monitor or placing big-
ger object than this unit may cause injury as the object
may become unbalanced and fall.
Fan Replacement
Fans mounted on the inner side of front panel and rear
panel are subject to wear and tear. Replace them every 3
years. It is recommended to fill in the provided label with
replacement date and paste it on this unit.
Consult your local JVC dealer when replacing fan.
In addition, the cover may deform due to the weight and
the component inside may damage resulting in fire and
electrical shock.
Power Cord
ⅥWipe this equipment using soft rags.
Ⅵ Do not use the power cord supplied with this equipment
on other devices.
Ⅵ Do not place heavy object on the power cord nor
placing the power cord under this unit.
This may cause damage to power cord, fire or electrical
shock.
Ⅵ Use the power cord supplied to this unit.
Using the power cord with different voltage rating or dam-
aged power cord may cause fire or electrical shock.
Wiping with thinner or benzene may dissolve or tarnish
its surface. For dirt that cannot be easily removed, wipe
using a neutral detergent diluted with water, followed by
wiping with a dry cloth.
ⅥDo not place object filled with water (vase, flowerpot,
cup, cosmetics and medicine etc).
It will result in fire and electrical shock if water is spilt into
the equipment.
ⅥDo not insert anything into the equipment. It will result in
fire and electrical shock if metal or inflammable object is
inserted from the ventilation hole.
Precautions on operation
Ⅵ The display of this unit may appear 2 seconds after turn-
ing on the power. This is compliant to the regulation of
high frequency of power supply and is not faulty.
6
Front Panel
6
5
4
1
POWER
POWER
ON
OFF
MULTI FORMAT
HIGH DEFINITION
TELEVISION
ENTER
ESC
FAULT
ENCODER
7
3 2
[POWER] Power switch
Switch to turn on/off power. After this is switched
to ON, a “Now Initializing” will be displayed on the
1
About Display
Ⅵ Normal display
Display
displayed.
of front panel before normal screen is
5
HDTV ENCODER
DM-JV600U
After turning on the power, it may take 2 sec-
onds before display light up.
Memo
Press the 8 / 9 buttons
Names
Display the control set-
ting status of this unit
[ESC] button
Press this button when switching Display
the front panel from menu setting display to nor-
mal display.
Changing of the setting value in Menu item can
also be cancelled by this button.
2
3
on
5
Displays the current
operation status
Local Running
SYN:HD-IN START:Auto
Display the setting sta-
tus of how encoding
will start
[ENTER] button
Press this button when switching Display
the front panel from normal display to menu set-
ting display.
Display the setting sta-
tus of reference syn-
chronized signal
on
5
Press the 8 / 9 buttons
Changing of the setting value in Menu item can
also be confirmed by this button.
V:1080i 20000kbps
Display the setting sta-
tus of encoding of
video signal
Refer to page 16 for changing the menu.
Memo
A:MPEG
384kbps
Display the setting sta-
tus of encoding of au-
dio signal
[8 / 9 / ; / :] buttons
4
5
Press this button to select menu item or change
the setting value of menu item during menu set-
ting display.
ⅥMain Menu
Main Menu
+Configuration Menu
Display
Indicate that sub menu is
present
The operation status, error content and menu
item of this unit will be displayed.
☞ Following item “About display”
ⅥSub Menu
C o n f i g u r a t i o n M e n u
> S a v e & R e b o o t
[POWER] indicator
Light up in green during operation.
6
7
I
ndicate executable
menu items or alterable
menu setting value
[FAULT] indicator
Status Menu
Light up in orange when error occurs on this unit.
- S t a t u s
: R u n n i n g
Indicate that sub menu is
not present
7
Rear Panel
8
9 0
!
@
#
$
AC 120V
~
50 Hz/60 Hz
IN
MONI
OUT
2
1
RS-232C
HD-
SDI
ASI OUT
REF IN(D1)
AES/EBU IN
[AC IN] Power input terminal
Use the power cord supplied to connect to an AC
120 V 50 Hz/60 Hz outlet.
8
9
[AES/EBU IN] Audio signal input terminal
(BNC)
Input terminal for digital audio signal (PCM or
Dolby™ Digital bitstream). Connect to the digital au-
dio signal output terminal of the device outputting
audio signal.
#
[HD-SDI IN] Video signal input terminal (BNC)
Input terminal for HD serial digital video signal.
This terminal also receives audio signal when
audio signal is embedded into HD serial digital
video signal.
Memo
When using the audio signal input terminal,
set the audio input item in the Configuration
Menu to “AES/EBU”.
Connect to the HD serial digital video signal out-
put terminal of the device outputting video signal.
☞ Page 13 “Configuration Menu”
[HD-SDI MONI OUT] Video signal output
terminal (BNC)
Output terminal for through HDTV serial digital
video signal.
0
Cautions
• For the audio signal to be input to AES/EBU
IN terminal, use the 48 kHz audio signal that
is synchronized with video signal.
For checking the video signal inputted into HD-
• If Dolby™ Digital bitstream is inputted when
the Audio Format under the Initial Param
Menu is set as “MPEG”, loud sound might
be produced. Make sure that “DD-PT” is set
before inputting Dolby™ Digital bitstream.
SDI IN video signal input terminal
on the rear
9
panel.
The output signal of HD-SDI MONI.OUT termi-
nal that has not gone through re-clock process
cannot be used as a formal SMPTE292M
(1080i/720p) standard HDTV serial digital
video signal.
Memo
[RS-232C]Remote terminal (D-sub 9pin)
By connecting to the device for remote control, con-
trol of this unit can be performed externally.
$
[ASI OUT] TS output terminal (BNC ×2)
!
TS output terminal.Encodes and outputs the
video signal inputted into HD-SDI IN video signal
Ⅵ
Pin assignment of RS-232C remote terminal
input terminal
into AES/EBU IN terminal
and the audio signal inputted
9
Pin No. Signal name
Content
.
#
9
6
This terminal also outputs encoded audio signal
when audio signal is embedded into HD serial
digital video signal.
1
2
3
4
5
6
7
8
9
N.C
RxD
TxD
N.C
SG
5
Received data
1
Transmitted data
[REF IN (D1)] External reference
@
Ground
synchronized signal input terminal (BNC)
Input external reference synchronized signal.
For reference synchronized signal, use the signal
that is compliant to SMPTE259M (D1).
N.C
N.C
N.C
N.C
When using the external reference synchronized
signal input terminal, set the Sync Mode item in
Memo
Tranfer speed 38.4 kbps
Data bit
Parity
StopBit
Flow Control
8 bit
None
1 bit
the Configuration Menu to “REF”.
☞ Page 13 “Configuration Menu”
None
• When using the external reference synchronized
signal, keep the phase difference of external ref-
erence synchronized signal and input video sig-
nal within 5H (1H: D1signal cycle).
Cautions
(Phase zero is defined when the forth pin of D1 sig-
nal matches with first pin of input video signal.)
• Input D1 signal before turning on the power of this
unit. The encoding may not start if D1 signal is not
input when the power of this unit is turned on.
8
Connecting
One example of the basic systems using this unit is described below.
Turn OFF the power of all devices before connecting or disconnecting.
HDTV VTR
AUDIO
INPUT
VIDEO
INPUT
AUDIO INPUT
SDI CH1
/
AUDIO MONITOR SELECT
POWER
CH2
CH2
CH2
CH3
CH3
CH3
CH4
CH4
CH4
SIF
ON
I
AUDIO
MONITOR
AES/EBU
CH1
L
ANALOG
CH1
R
LINE
CPN
Synchronized Signal
Generator
OFF
O
REF signal
CH1
CH2
P
CH3 CH4/TRACKING
SEARCH VAR
PLAYERRECORDER
R
P
R
R
P
R
P
COUNTER RESET
VCON
HOLD
REMOTE
525
TE 625
CONDITION
CTLTCUB DF SERVOCFGEN16:9 AP
AUTOOFFP.READV.V RPB/EE
dBOVER dB
dBOVER dB
dBOVER dB
dBOVER dB
0
0
0
0
A
R
E
M
O
UB
+4
+4
+4
+4
PB
PB/EE
+2
0
+2
0
+2
0
+2
0
P.PLAY
MENU
REC
SET
STILL
H
M
S
F
ASSEM VIDEO
DA1
DA2
DA3
DA4
EJECT
PLAY
PAUSE/STILL
X1
X-1
CH1
CH2
CH3
CH4
PHONES
TRACKING
REC
INSERT
IN
ENTRY OUT
TC
TOP
VIDEO
STOP
AUDIO
FF
PULL FOR VARIABLE
PLAY
STAND BY
REW
METER MODE
FINE TRACKING
AUTO EDIT
CANCELPREVIEW
REVIEW
PREROLL
USER
PULL
RELEASE
PULL
RELEASE
FWD
D1 signal
SHIFT
SERVO/SYS
TIME CODE
ON SCREEN
OTHERS
REV
HD-SDI OUT
AES/EBU OUT
DIGITAL AUDIO signal
Dolby™ Digital
ENCODER
HD-SDI signal
Dolby™
Digital bitstream
DM-JV600U
HD-SDI IN
IN
REF IN(D1)
AES/EBU IN
AC IN 120V ~ 50 Hz/60 Hz
MONI.
OUT
RS-232C
2
1
HD-
SDI
ASI OUT
AES/EBU IN
REF IN(D1)
ASI OUT
ASI OUT
Supplied power cord
DVB-ASI signal
DVB-ASI signal
AC 120V 50 Hz/60 Hz
P
DIGITAL VIDEO RECORDER
SR-VDA300U
DVB-ASI IN
HDTV DECODER
DM-D4600U
CABLE BOX
VHF/UHF
ANTENNA
Y
PR/CR
IN(L-1)
IN
ASI IN
R
AUDIO
L
VIDEO
R
AUDIO
VIDEO
TRISYNC IN
AES/EBU OUT CH1
2
HD
Pr
AC IN
POWER
1
3
REMOTE PAUSE/
AV COMPULINK
TV
IN(L-2)
S
VIDEO
S
VIDEO
OUT
OUT
G
ALARM
OUT
OUT
IN
SDI OUT
IN
ASI
Pb
Y
1
2
3
AC120V
1A
RS-422
RS-232C
10BASE-T
AUDIO VIDEO OUT
B
.
B
I
N
AES/EBU OUT CH2
SD
DVSI
SYNC
POL
+
ANALOG VIDEO OUT
(Y, Pb, Pr)
AES/EBU OUT
DIGITAL AUDIO signal
AMP
Speaker
DIGITAL
AUDIO IN
Monitor
ANALOG VIDEO signal
VIDEO IN
If there is interruption of input signal due to switching of HD-SDI input signal or reconnection of signal cable,
video or audio signal may not output for about 20 seconds.
Cautions
When [AES/EBU] terminal is set and used as Audio Input (
Page 13) terminal under the Initial Param Menu
☞
screen, noise may be introduced into the audio signals if [REF IN] and [HD-SDI IN] are stopped halfway.
In addition, when the Dolby™ Digital bitstream is inputted from devices such as DVD player that is not synchro-
nized externally, audio signal might be mixed with noise.
Use the following specified cables to avoid misoperation.
• HD-SDI input cable
: 5C-FB, less than 10 m
• HD-SDI monitor output cable : 5C-FB, less than 3 m
This unit may output a full-screen grey signal depends on the following input signal status.
• When the input video signal that is not compliant to SMPTE292M (1080i/720p) is detected
• If the phase difference against input video signal exceeds the range of 5H when synchronizing to external
signal generator
9
Mounting to a Rack
By making use of the hole on inner side of front panel, this unit can be mounted to EIA rack.
Caution
• When mounting this unit to
rack, mount the L shape
bracket to both ends of the
rack to ensure strength.
• When mounting to the rack,
mount it in the way such that
this unit will not protrude out
from the rack.
Remove the foot
(The depth of the rack should
be at least 700 mm)
Foot
P
O
W
E
R
O
N
Remove the front panel
O
F
F
EIA Rack
Mount this unit to rack using the supplied
4 screws
Return the front panel to its original sta-
tus
P
O
W
E
R
O
O
N
FF
Front Panel
Caution
Do not remove the mounting bracket.The
mounting may become unstable due to
loosen screws. In addition, if the mounting
direction of the bracket is wrong, it will be
extremely dangerous as the bracket will not
be properly mounted onto the rack.
10
Menu Flow Chart
The menu of this unit consists of 3 level of menus namely “Main menu”, “Sub menu” and “Setting items”.
Display screen
Menu Item
Main Menu
Sub Menu
Setting
HDTV ENCODER
DM-JV600U
ENTER
• Video Rate
• Asp
ENTER
ENTER
ESC
• 32Pulldown
• Audio Mode
• Audio Rate
• Start
Main Menu
Configuration Menu
+ Operate Param Menu
+ Configuration Menu
ESC
Setting of the encoding bit rate/starting
method of encoding/various parameters,
saving and reset of the menu item setting
are possible.
☞ Page 12
• Stop
“Operate Param Menu”
• Control Mode
• Start Mode
ENTER
ESC
Configuration Menu
+ Initial Param Menu
• Sync Mode
• TS Rate
• Video Mode
• Audio Format
• Audio Input
☞ Page 13
“Initial Param Menu”
u
ENTER
ESC
Main Menu
+ Status Menu
• Audio ExDelay
• Audio Enable
• PSI Enable
Men
Configuration Menu
>Save & Reboot
Current operation status and error log can
be confirmed.
• PAT TS ID
• PMT PID
☞ Page 16
• PCR PID
“
How to Change Menu Setting”
• Video PID
• Audio PID
• Video Stream ID
• Audio Stream ID
• Video Copyright
• Video Org/Copy
• Audio Copyright
• Audio Org/Copy
Configuration Menu
>Default & Reboot
Main Menu
+ Administration Menu
☞ Page 17
“
Restoring the Default Menu Setting Value”
Administrator menu. Password is required
to operate.
Status Menu
☞
Page 22
”
“Using the Administration
- Status
: Running
Menu
☞ Page 20
“
Checking Operation Status”
Status Menu
+ Log
☞ Page 21
Checking Error Log
“
”
11
Menu Setting
Configuration Menu
ꢀ : Default setting
Item
Setting value
Content
Operate Param
Menu
Memo
Video Rate
9000kbps
to
20000kbps ꢀ
to
Set the bit rate of the encoded video signal.
The setting value can be set in 10 kbps step.
When the Audio Enable un-
der the Initial Param Menu
screen is set to ON, the up-
per limit value of Video
Rate is
When the Audio Format un-
der the Initial Param Menu
screen is set as
40000kbps
Asp
Ⅵ When the Video Mode
item in the menu is set
to “1080i”
Set the horizontal size of the encoded video signal.
16:9 1920 × 1080: Encode with 1920(H) × 1080(V) size
16:9 1440 × 1080: Encode with 1440(H) × 1080(V) size
16:9 1280 × 1080: Encode with 1280(H) × 1080(V) size
16:9 1280 × 720: Encode with 1280(H) × 720(V) size
• MPEG: TS Rate - 700kbps
•
DD-PT (Dolby™ Digital
Pass Through) : TS Rate -
1000kbps
16:9 1920
16:9 1440
16:9 1280
×
×
×
1080 ꢀ
1080
When Audio Enable is set to
OFF,
1080
• TS Rate - 200kbps
Ⅵ When the Video Mode
item in the menu is set
to “720p”
16:9 1280
×
720
3-2Pulldown
Auto ꢀ
Set the 3-2 Pulldown.
OFF
Auto
:
Perform 3-2 Pulldown process automatically
depends on the video signal.
OFF : Does not perform 3-2 Pulldown process.
☞ Page 26 “Setting the 3-2 Pulldown”
Memo
•
•
The setting value of the
Audio Rate item in the
Operate Param Menu
may change if Audio
Mode setting is changed.
The setting of Audio
Mode and Audio Rate un-
der the Operate Param
Menu are disallowed
when Audio Format under
the Initial Param Menu is
Audio Mode
Audio Rate
Stereo ꢀ
Set the channel mode of the audio encoded signal.
Stereo : Encode with stereo mode.
Single
Single : Encode with single channel mode (monaural).
Ⅵ
When the Audio Mode
item in the menu is set
to “Stereo”
Set the bit rate of the encoded audio signal.
384kbps ꢀ
256kbps
192kbps
set as DD-PT (Dolby
Digital Pass Through).
™
Ⅵ When the Audio Mode
item in the menu is set
to “Single”
192kbps
128kbps
96kbps
Start
Stop
Start the encoding.
☞ Page 18 “Starting the Encoding”
Stop the encoding.
☞ Page 19 “Stop the encoding manually”
12
Configuration Menu
ꢀ : Default setting
Item
Setting value
Content
Initial Param
Menu
Set the operation mode of this unit.
Control Mode
Local
ꢀ
Local : Set to this mode when operating this unit
using the buttons on the front panel.
Remote
Remote : Set to this mode when using RS-232C
terminal
on the rear panel to perform
$
remote control of this unit.
Set the starting mode of encoding.
Start Mode
Auto
ꢀ
Auto
: Start the encoding automatically.
Manual
Manual : Start the encoding using the menu.
☞ Page 18 “Starting the Encoding”
Memo
When input video sig-
nal is used in synchro-
nized mode, video sig-
nal may not output for
about 20 seconds due
to switching of signal or
reconnection of signal
cable.
Set the synchronized signal that is the reference for encoding.
HD-IN : Synchronize with the input video signal.
REF : Synchronize with the D1 signal input into
Sync Mode
TS Rate
HD-IN
REF
ꢀ
REF IN terminal on the rear panel.
@
Set the TS bit rate.
The setting value can be changed in 10 kbps step.
10000kbps
to
u
21000kbps
to
ꢀ
Memo
Men
50000kbps
The setting value of the
Video Rate item in the Op-
erate Param Menu may
change if TS Rate setting
value is changed.
Set the Video Mode.
Encode with 1080i: 1080i format.
Encode with 720p: 720p format.
Video Mode
1080i
720p
ꢀ
Memo
Setting the Audio Format.
Audio Format
MPEG
DD-PT
(Dolby™ Digital Pass
Through)
ꢀ
The setting value of the Asp
item in the Operate Param
Menu may change if Video
Mode setting value is
changed.
MPEG : Encoding with MPEG Layer 2.
DD-PT(Dolby™ Digital Pass Through) :
Dolby™ Digital bitstream will be output in TS
Format.
Select the input audio signal.
AES/EBU : Encode the audio signal input into AES/EBU
Audio Input
AES/EBU
EMB
ꢀ
terminal
on the rear panel.
#
EMB
: Encode the Embedded audio signal
input into HD-SDI IN terminal
rear panel.
on the
9
Memo
This setting is meant for compensating the delays
introduced when encoders are connected to
external equipment.
(Denary, Millisecond unit)
Setting value is 1 ms step variable.
Audio ExDelay
Audio Enable
1ms
to
10ms
to
This setting is only valid
when Audio Format is set
ꢀ
as DD-PT (Dolby
™
Digital
Pass Through).
500ms
Set whether to output audio signal or not.
ON : Output audio information.
ON
ꢀ
OFF
OFF : Does not output audio information.
13
Menu Setting
Configuration Menu (continued)
ꢀ : Default setting
Item
Setting value
Content
Initial Param
Menu
PSI Enable
ONꢀ
Set the PSI (Program Specific Information) to ON/
OFF.
OFF
ON : PAT and PMT will be output.
OFF : PAT and PMT will not be output.
PAT TS ID
PMT PID
0001
to
Set the ID of PAT TS.
PAT TS ID is the Transport Stream ID within PAT.
PAT (Program Association Table) is the correspondences
table of Program number and PMT PID.
0001ꢀ
to
FFFF
0010
to
Set the PMT Packet ID.
PMT (Program Map Table) is an index table that
designates the various stream PIDs which
constituted the program.
0010ꢀ
to
1FFE
PCR PID
0010
to
Set the PCR Packet ID.
PCR (Program Clock Reference) is clock data that is
output periodically.
It is used by the decoder to synchronize with internal
clock for PLL synchronization.
0101ꢀ
to
1FFE
Video PID
Audio PID
Video Stream ID
0020
to
Set the Video Packet ID.
0102ꢀ
to
1FFE
0020
to
Set the Audio Packet ID.
0103ꢀ
to
1FFE
E0
to
Set the ID of Video PES stream.
E0ꢀ
to
EF
14
Configuration Menu (continued)
ꢀ : Default setting
Item
Setting value
Content
Initial Param
Menu
Memo
This setting is disabled
when Audio Format under
the Initial Param Menu
screen is set as DD-PT
(Dolby™ Digital Pass Through).
(Fixed as 0xBD)
Audio Stream ID
C0
to
Set the ID of Audio PES stream.
C0ꢀ
to
DF
Video Copyright
OFFꢀ
Set the copyright flag of Video PES.
ON
OFF : Set the copyright flag of Video PES to OFF.
ON : Set the copyright flag of Video PES to ON.
Video Org/Copy
Audio Copyright
Orgꢀ
Copy
Set the Original/ Copy of Video PES.
Org : Set the Video PES to Original.
Copy: Set the Video PES to Copy.
OFFꢀ
Set the copyright flag of Audio PES.
ON
OFF : Set the copyright flag of Audio PES to OFF.
ON : Set the copyright flag of Audio PES to ON.
u
Men
Audio Org/Copy
Orgꢀ
Copy
Set the Original/ Copy of Audio PES.
Org : Set the Audio PES to Original.
Copy : Set the Audio PES to Copy.
Save & Reboot
Save the setting value of the menu and restart this unit.
☞ Page 18 “Starting the Encoding”
Default & Reboot
Return the setting value of the menu to default and
restart this unit.
☞
Page 17 “Restoring the Default Menu Setting Value”
15
How to Change Menu Setting
The various features of this unit can be set using the menu. The setting value, which is stored in the
internal memory will reappear upon turning on the power.
Display
8 / 9 / ; / :buttons
Ⅵ Example
Remote control of this unit
can be achieved by using
POWER
POWER
FAULT
ON
MULTI FORMAT
ENTER
ESC
HIGH DEFINITION
TELEVISION
ENCODER
OFF
the RS-232C terminal on
the rear panel.
[Configuration Menu]
ENTER ESC
button button
≠
[Initial Param Menu]
≠
[Control Mode]
≠
Operation Flow Chart
Display Flow Chart
“Remote”
Press the ENTER button
Main Menu
Main Menu screen will be displayed.
+Configuration Menu
Press the 8 / 9 buttons
Main Menu
Select the Configuration Menu.
+Configuration Menu
Press the ENTER button
Configuration Menu screen will be displayed.
Configuration Menu
+Operate Param Menu
Press the 8 / 9 buttons
Select the Initial Param Menu.
Configuration Menu
+Initial Param Menu
Press the ENTER button
Initial Param Menu screen will be displayed.
Initial Param Menu
>Control Mode :Local
Press the 8 / 9 buttons
Select the Control Mode item and press the ENTER button.
Initial Param Menu
>Control Mode: Local
Press the 8 / 9 buttons
Select the “Remote” and press the ENTER button.
Initial Param Menu
>Control Mode:Remote
Memo
The Operate Param Menu
setting will be reflected in
the output even if “Save &
Reboot” is not executed.
Press the ESC button
Initial Param Menu
>Save & Reboot ?
Press the ENTER button
Caution
. . N o w I n i t i a l i z i n g . .
Do not turn off the power
switch during “Now Initializ-
ing” display.
The setting value may not
be saved or may return to
default setting.
HDTV ENCODER
DM-JV600U
16
Restoring the Default Menu Setting Value
Each feature that has been set using the menu can be returned to default (factory setting).
All the menu settings return to default.
Operation Flow Chart
Display Flow Chart
Press the ENTER button
Main Menu
Main Menu screen will be displayed.
+Configuration Menu
Press the 8 / 9 buttons
Main Menu
Select the Configuration Menu.
+Configuration Menu
Press the ENTER button
Configuration Menu screen will be displayed.
Configuration Menu
+Operate Param Menu
Press the 8 / 9 buttons
Select the Default & Reboot.
Configuration Menu
>Default & Reboot
Caution
Do not turn off the
power switch during
“Now Initializing” dis-
play.
Press the ENTER button
Execution confirmation screen will be displayed.
Configuration Menu
>Default & Reboot ?
Bas
Press the ENTER button
Setting to default of the menu setting and reboot of this
unit will be performed.
. . N o w I n i t i a l i z i n g . .
HDTV ENCODER
DM-JV600U
17
Starting the Encoding
There are 2 ways to start the encoding. One is to start the encoding automatically and the other one
is to start it manually by setting the menu.
Display
8 / 9 / ; / :buttons
POWER
POWER
FAULT
ON
MULTI FORMAT
ENTER
ESC
HIGH DEFINITION
TELEVISION
ENCODER
OFF
ENTER ESC
button button
Start the encoding automatically
Memo
Operation Flow Chart
Display Flow Chart
The default setting of the
Start Mode item is set to
“Auto” in order to start the
encoding automatically.
☞ Page 13 “Start Mode
item”
Press the ENTER button
Display the Initial Param Menu screen according to
steps 1~5 on Page 16 “How to Change Menu Setting”.
I n i t i a l P a r a m M e n u
>Control Mode :Local
Press the 8 / 9 buttons
I n i t i a l P a r a m M e n u
Select the Start Mode item and press the ENTER but-
>Start Mode
:Auto
ton.
Memo
The encoding can be man-
ually started or stopped if
the Start Mode item in the
menu is set to “Manual”.
☞ Page 19 “Start the
encoding manually”
Press the 8 / 9 buttons
Select the “Auto” and press the ENTER button.
I n i t i a l P a r a m M e n u
>Start Mode :Auto
Press the ESC button
I n i t i a l P a r a m M e n u
>Save & Reboot ?
Press the ENTER button
The encoding will start after the menu setting is saved
and reboot of this unit is performed.
. . N o w I n i t i a l i z i n g . .
HDTV ENCODER
DM-JV600U
18
Ⅵ Set the Start Mode item
in the menu to “Manual” ac-
cording to the procedure on
☞ Page 18 “Start the
encoding automati-
cally”.
Start the encoding manually
Memo
Operation Flow Chart
Display Flow Chart
The encoding will stop if menu
item has been changed dur-
ing manual encoding and
“>Save&Reboot” has been
excecuted.
Press the ENTER button
Main Menu screen will be displayed.
Main Menu
+Configuration Menu
Start the encoding manually
once again.
Press the 8 / 9 buttons
Select the Configuration Menu and press the ENTER
button.
C o n f i g u r a t i o n M e n u
+Operate Param Menu
Press the 8 / 9 buttons
Select the Operate Param Menu and press the EN-
TER button.
Operate Param Menu
VideoRate:20000kbps
Press the 8 / 9 buttons
Select the Start item and press the ENTER button.
Operate Param Menu
>Start?
Press the ENTER button
This starts the encoding.
Stop the encoding manually
Bas
Operation Flow Chart
Display Flow Chart
Press the ENTER button
Main Menu
Main Menu screen will be displayed.
+Configuration Menu
Press the 8 / 9 buttons
Select the Configuration Menu and press the ENTER
C o n f i g u r a t i o n M e n u
+Operate Param Menu
button.
Press the 8 / 9 buttons
Select the Operate Param Menu and press the EN-
Operate Param Menu
VideoRate:20000kbps
TER button.
Press the 8 / 9 buttons
Select the Stop item and press the ENTER button.
Operate Param Menu
>Stop?
Press the ENTER button
Stop the encoding.
19
Checking Operation Status
The operation status of this unit can be confirmed from the display.
Display
8 / 9 / ; / :buttons
POWER
POWER
ON
MULTI FORMAT
HIGH DEFINITION
TELEVISION
ENCODER
ENTER
ESC
FAULT
OFF
ENTER ESC
button button
Operation Flow Chart
Display Flow Chart
Press the ENTER button
Main Menu screen will be displayed.
Main Menu
+Configuration Menu
Press the 8 / 9 buttons
Select the Status Menu.
Main Menu
+Status Menu
Press the ENTER button
Status Menu screen will be displayed.
Status Menu
- S t a t u s
: R u n n i n g
: R u n n i n g
Press the 8 / 9 buttons
Current operation status will be displayed by selecting
the Status item.
Status Menu
- S t a t u s
Memo
Indicate that the encoding
is in process.
Status Menu
- S t a t u s
: R u n n i n g
: R e a d y
Indicate that the encoding
is in standby status.
Status Menu
- S t a t u s
Indicates that fatal error
has occurred.
Status Menu
- S t a t u s : F a t a l e r r o r
☞ Page 24 “Error Log”
20
Checking Error Log
The error occurrence can be confirmed on the display. Up to 64 occurrences can be stored.
Operation Flow Chart
Display Flow Chart
Press the ENTER button
Main Menu
Main Menu screen will be displayed.
+Configuration Menu
Press the 8 / 9 buttons
Main Menu
Select the Status Menu.
+Status Menu
Press the ENTER button
Status Menu
Status Menu screen will be displayed.
- S t a t u s
: R u n n i n g
Press the 8 / 9 buttons
Select the Log item and press the ENTER button.
Status Menu
+Log
Press the 8 / 9 buttons
The error log stored will be displayed.
00:Feb07 14:06 0001
-system boot
For detailed error log display, read page 24 “Error log”.
Bas
21
Using the Administration Menu
The information regarding built-in program or firmware version can be obtained from the
Administration Menu. In addition, clock setting and the display brightness could be adjusted.
* Please carry out the clock setting before use.
Display
8 / 9 / ; / :buttons
POWER
Ⅵ Examples of setting
Setting the clock using
the Administration Menu
screen.
POWER
FAULT
ON
MULTI FORMAT
ENTER
ESC
HIGH DEFINITION
TELEVISION
ENCODER
OFF
ENTER ESC
button button
Operation Flow Chart
Display Flow Chart
Press the ENTER button
Main Menu screen will be displayed.
Main Menu
+Configuration Menu
Press the 8 / 9 buttons
Main Menu
Select the Administration Menu.
+Administration Menu
Press the ENTER button
The Administration Menu screen will be displayed.
Administration Menu
-Model
:DM-JV600U
Press the 8 / 9 buttons
Choose the Time item and press ENTER button.
Administration Menu
>Time : 04/03/19 22:00
Press the 8 / 9/; / : Buttons
; / : Buttons
: Move the cursor to the highlight
Administration Menu
>Time : 04/03/19 22:0
the places when changes are to
be made.
At the selected places,
cursor will start to blink.
8/ 9 Buttons
: Change the values highlighted by
the cursor.
Press the [ENTER] button once charges are made.
22
Administration menu
Item
Content
Model
SerNo
Time
Displays the model name.
Displays the serial number.
Setting the Clock.
Year/Month/Day Hour : Minute (For the Year setting,
only the last 2 digits of the year will be used)
FL Brghtness
(Initial Setting: 0)
Setting the Display brightness.
Setting range is between 0 to 3.
0 : Brightest setting.
Firm
Displays the firmware version.
Ucode
Displays the version of the µ code.
Displays the version of boot program.
Displays the version of MISC FPGA.
Displays the version of STC FPGA.
Displays the version of I/O PWB.
Displays the version of I/O VI PLD.
Displays the version of I/O AU PLD.
Boot
MISC FPGA
STC FPGA
I/O PWB
I/O VI PLD
I/O AU PLD
Bas
23
Error Log
The stored error log can be displayed by performing the operation on page 21 “Checking Error Log”.
The error content is displayed by error code.
Display
a
b
c
d
e
a: Error log No.
b: Error occurrence date
c: Error occurrence time
d: Error code
00 : Feb07 14 : 06 0001
-system boot
e: Error content
*For the error content with plenty of characters, press
the ; / : buttons to scroll the display.
*The date and hour of this unit is adjusted to Green-
wich Mean Time (GMT).
Error code
Cause of error
Troubleshooting
Error code:Error content
Restart of this unit has been performed.
0001:
system boot
The communication error caused by control
device communication has occurred.
Confirm the connection to external
device.
0020:
communication error
Confirm the setting of external de-
vice.
The value of command and parameter created
by control device communication is abnormal.
0021:
command parameter error
This unit has received action command
when it is busy.
0022:
command busy
The synchronized signal cannot be de-
tected.
Confirm the connection to external
synchronized signal generator and
the synchronized signal itself.
0040:
sync input error
0041:
sync input error recover
The detection of the synchronized signal
has timed out when this unit restarts.
0050:
sync no input timeout error
The video input signal is abnormal.
Confirm the connection between
HD-SDI IN terminal and connected
device.
0080:
enc hardware video input error
Confirm the signal input into HD-
SDI IN terminal
0081:
enc hardware video input error recover
The audio input signal is abnormal.
Confirm the connection between
AES/EBU IN terminal and con-
nected device.
0084:
enc hardware audio input error
Confirm the signal input into AES/
EBU IN terminal.
0085:
enc hardware audio input error recover
Resync process has occured when syn-
chronizing to video input signal.
Confirm the connection between HD-
SDI IN terminal and connected
device(Frequent reconnection of the
connector may cause the error).
Confirm the signal input into HD-SDI IN
terminal.
0088:
enc hardware resync
24
Error code
Error code:Error content
Cause of error
Troubleshooting
0002:
parameter error
The content of the internal parameter
(default parameter and others) is ab-
normal.
This unit is abnormal.
Switch the power to “OFF” and turn
on the power again. Consult your
local JVC dealer if the problem is
still unsolved.
0008:
FAN operation is abnormal.
FAN stop error
0009:
FAN stop error recover
001a:
FAN stop timeout error
0013:
hardware fatal error
The hardware of this unit is abnormal.
The software of this unit is abnormal.
The restart of this unit is abnormal.
0014:
software fatal error
0015:
system boot fatal error
0044:
The interruption of video frame has
timed out.
video frame interrupt timeout error
0045:
video frame interrupt timeout error recover
0060:
The IC inside this unit is abnormal.
domino chip running error
0061:
domino chip running error recover
0072:
domino chip boot fatal error
0073:
domino chip running fatal error
00a0:
The process of the input stage of video
signal is abnormal.
enc software video input error
00a1:
enc software video input error recover
s
00a2:
enc software video running error
O
00a3:
enc software video running error recover
00a8:
The process of the input stage of audio
signal is abnormal.
enc software audio input error
00a9:
enc software audio input error recover
00aa:
enc software audio running error
00ab:
enc software audio running error recover
25
Setting the 3-2 Pulldown
Encoding image film material
It is required to convert the video signal (Pulldown) in order to view the image recorded with
24 frames per second such as movie film on a system for HDTV video signal that is 30
frames per second (60 field) used in TV broadcasting. Normally, HDTV VTR utilize 3 - 2
Pulldown (Telecine) method to achieve image signal conversion before recording on tape.
When this equipment is encoding signals which have been recorded with 3 - 2 Pulldown
processing, it is possible to encode by automatically skip 24 frames in order to increase
compression ratio. (Inverse Telecine)
3-2 Pulldown auto setting
For 3-2 Pulldown method, the odd number frame is converted to 2 fields and the even num-
ber frame is converted to 3 fields. With this feature, it is possible to convert 2 frames into 5
fields which means that 24 frames could be converted into 60 fields.
Film
1st scene
2nd scene
3rd scene
4th scene
Field Field Field Field Field Field Field Field Field Field
HDTV VTR
1
2
1
2
1
2
1
2
1
2
Frame 1
Frame 2
Frame 3
Frame 4
Frame 5
Frame 4
ENCODER
Frame 1
Frame 2
Frame 3
When 3- 2 Pulldown under the Operate Param Menu is set to AUTO, input image signals will
automatically be detected for 3 -2 Pulldown processing information, unnecessary fields will
be discarded and only the original 24 frames will be encoded.
26
Specifications
<Input signal>
Ⅵ Video input
SMPTE292M (common for 1080i/720p)
SMPTE299M (Embedded Audio)
HD SDI IN ×1
800 mVp-p, 75 Ω (BNC unbalanced)
1080i:1920 × 1080 frame frequency 29.97Hz
720p:1280 × 720 frame frequency 59.94Hz
Ⅵ Audio input
AES/EBU
AES/EBU IN ×1
(48 kHz sampling frequency synchronized with video
signal)
1 Vp-p, 75 Ω (BNC unbalanced)
Ⅵ Synchronized input
SMPTE259M
REF IN ×1
800 mVp-p, 75 Ω (BNC unbalanced)
<Output signal>
Ⅵ Video output
SMPTE292M(common for 1080i/720p)
MONITOR OUT ×1
800 mVp-p, 75 Ω (BNC unbalanced)
DVB/ASI(188byte format,packet mode)
ASI OUT ×2
800 mVp-p, 75 Ω (BNC unbalanced)
<Video encoding>
<Audio encoding>
Video encoding profile
1080i MP@HL
1080i MP@HL
1080i MP@HL
Video bit rate
MPEG-2
1920 × 1080 59.94 Hz
1440 × 1080 59.94 Hz
1280 × 1080 59.94 Hz
9Mbps~40 Mbps
9Mbps~40 Mbps
9Mbps~40 Mbps
9Mbps~40 Mbps
(ISO/IEC13818-2)
720p MP@H14L 1280 × 720 59.94 Hz
MPEG-1 Layer 2
ꢀ Stereo mode
ꢀ Single mode
(ISO/IEC11172-3)
Bit rate
Bit rate
384 kbps
256 kbps
192 kbps
48 kHz
192 kbps
128 kbps
96 kbps
48 kHz
Sampling
Sampling
Channel : 1-5.1 channel
Sampling : 48 kHz
Dolby™ Digital(AC-3) Pass
Through
Bit rate : 56 kbps to 640 kbps
<General>
RS-232C ×1
Ⅵ Interface
AC 120 V 50 Hz/60 Hz
70 W , 0.6 A
5 °C to 40 °C
–20 °C to 60 °C
30 % to 80 %
Approx. 10 k˝
Ⅵ Power supply
Ⅵ Power consumption
Ⅵ Allowable operating temperature
Ⅵ Allowable storage temperature
Ⅵ Allowable operating humidity
Ⅵ Mass
<Appearance>
<Accessories>
Ⅵ Instruction Manual .............. ×1
465
430
Ⅵ
Power cord (2.4 m) ................... ×1
[unit : mm]
Ⅵ Screws for mounting rack ... ×4
A
E
S
/
E
B
U
I
N
R
E
F
I
N
(
D
1
)
A
S
I
O
U
T
S D I
H D -
O U T
R S - 2 3 2 C
1
2
M O N I
I N
A C 1 2 0 V
~
5 0 / 6 0 H z
Ⅵ Label ................................... ×1
POWER
ON
OFF
482
*Dolby is a trademark of Dolby Laboratories.
27
*Specifications and appearance of this unit are subject to change for improvement without prior notice.
VICTOR COMPANY OF JAPAN, LIMITED
¨
¨
is a registered trademark owned by VICTOR COMPANY OF JAPAN, LTD.
is a registered trademark in Japan, the U.S.A., the U.K. and many other countries.
© 2004 VICTOR COMPANY OF JAPAN, LIMITED
Printed in japan
LST0159-001C
|