Intel Security Camera NSC2U User Manual

Intel® IP Network Server NSC2U  
Configuration Guide System / Spares / Accessories List  
March 2008  
Rev 2.2  
Reference guide to assist customers and the field in ordering the servers,  
accessories and spares  
~Subject to Change Without Notice~  
 
I. Introduction  
Product Description:  
The Intel® IP Network Server NSC2U system is the second generation product of 2U  
Intel® IP Network Server products, having long product life and 20-inch depth  
chassis. This server combines network port density and processor performance in a  
compact 2U package. The NSC2U supports a number of processor speeds for the  
Quad-Core Intel® Xeon® 5300 and 5400 series processors, coupling high performance  
with power efficiency to provide improved performance-per-watt over previous-  
generation rack-mount servers. The NSC2U also supports a number of processor  
speeds for the Dual-Core Intel® Xeon® 5100 series processors.  
The NSC2U is an excellent choice for network data applications with large I/O  
requirements, while providing extended lifecycle support, DC power capabilities,  
compact form factor, and the ruggedness found on carrier-grade servers. Ideal for  
network security, it is an excellent choice for intrusion detection/intrusion  
prevention, VPN/firewall, and unified threat management solutions. In addition, it  
is a valuable platform for running Telco SoIP, including IMS, IPTV, Video on Demand  
(VoD), SIP application servers, IP-PBX, and IP-PSTN Gateways. Other network  
applications well-suited for this platform are enterprise application acceleration and  
content caching.  
More product information is available at the following websites:  
NSC2U Product Overview:  
NSC2U Product Support:  
Purpose of this Document:  
This document provides details on what parts are available for ordering of the Intel®  
IP Network Server NSC2U production systems. This includes PID and MM#  
information for System SKUs, Accessories & Spares, as well as other Intel parts that  
are supported by the NSC2U product.  
Supported third-party components are not covered by this document, and may be  
found in the Tested Hardware and Operating System List (THOL) for this product.  
3/28/2008  
v 2.2  
4 of 20  
 
 
II. Production System SKUs  
The NSC2U Production System SKUs that can be ordered are listed below:  
Product  
Identification Code  
Min. Order  
Description  
MM#  
Qty.  
Intel® IP Network Server NSC2U,  
Base Model 0 with AC Power Supply  
NSCA0201W  
NSCD0201W  
889358  
1
Intel® IP Network Server NSC2U,  
Base Model 0 with DC Power Supply  
889357  
1
See the NSC2U Base Model 0 Configuration table further down in this section for a  
list of components included in each base model 0 SKU.  
Production SKUs are offered as either an AC or DC version. The Product  
Identification code, or PID, of all SKUs contains either the letter “A” for AC or “D”  
for DC as the 4th digit of the PID.  
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard  
drive, power cord, operating system, or plug-in adapters are provided). Those  
components must be ordered separately as Accessories from Intel or from third  
party vendors listed in the Tested Hardware and Operating System List (THOL).  
Power Cords are not included with the Mod 0 system. For AC Power cords, order the  
NA – North American power cord below. This power cable is RoHS-compliant.  
PID  
MM#  
Comments  
This AC power cable can be ordered by North  
America (NA) customers. International customers  
should procure their specific power cords directly.  
PWRCABLEUS 816324  
Note: Ensure that customers have the appropriate technical support and contact  
before placing their first order.  
3/28/2008  
v 2.2  
5 of 20  
 
 
NSC2U Base Model 0 Configuration:  
All Production SKUs are base model 0 SKUs (no processor, heatsink, memory, hard drive,  
power cord, operating system, or plug-in adapters are provided). Those components must  
be ordered separately as Accessories from Intel or from third party vendors listed in the  
Tested Hardware and Operating System List (THOL).  
The table below lists which components are included in the base model 0 SKUs and which  
ones must be ordered separately or as optional accessories.  
AC Mod 0  
Configuration Configuration  
DC Mod 0  
Component Description  
AC power supply (600 W)  
DC power supply (600 W)  
1 included  
-
-
1 included  
Filler Panel in 2nd power supply bay  
Chassis (bezel, sheet metal, top cover, PCI carrier)  
Server Board T5000PAL  
1 included  
1 included  
1 included  
Bezel (gray)  
1 included  
PCI Riser FH-FL (two PCI-Express and one PCI-X slots)  
PCI Riser LP (two PCI-Express slots)  
FB-DIMM slots (memory not included)  
Trays for hot-swap 2.5” SAS Hard Disk Drives  
Filler Panel in optical device bay  
Rear Panel GbE NIC (Cu) ports (via Server Board)  
Server Deployment Toolkit (CD)  
Quick Start Guide  
1 included  
1 included  
8 included  
6 included  
1 included  
2 included  
1 included  
1 included  
Power Cable  
SW RAID 0/1/10  
Purchase separately1  
Included  
HW RAID 5  
Optional Accessories2  
Optional Accessory2  
Optional Accessory2  
Optional Accessory2  
Optional Accessories2  
Optional Accessory2  
Optional Accessory2  
Optional Accessory4  
Purchase separately5  
Accessory or purchase separately  
Purchase separately5  
Purchase separately5  
Purchase separately5  
Intel® Z-U130 Value Solid State Drive  
Mounting kit for Intel® Z-U130 Value Solid State Drive  
Remote Management Module 2  
PCI-X FH-FL Riser (3 PCI-X slots)  
Ethernet I/O Module (dual Gigabit rear ports)  
SAS I/O Expansion Module (x4 external rear port)  
Rack Mount Kits  
Processor (refer to “Details on Ordering Processors”)  
Heatsink  
Memory  
Hard Disk Drive  
Optical Drive  
Accessories for NIC-in-Front Capability3  
Quad Port Bypass Adapter (Copper)  
Quad Port Bypass Adapter (Fiber)  
Optional Accessory3  
Optional Accessory3  
Optional Accessory3  
Optional Accessory3  
Quad NIC-in-Front Mounting Kit (Copper)  
Quad NIC-in-Front Mounting Kit (Fiber)  
1Refer to AC power cord accessory in this section  
2Refer to “Production Spares/Accessories List” in section III  
3Refer to “Quad Port Bypass NIC Capability” in section IV  
4Refer to “Rack Mounting Options” in the Appendix  
5Should be purchased separately (parts not listed in this document)  
3/28/2008  
v 2.2  
6 of 20  
 
Notes on the NSC2U Model 0 Configuration and Options:  
ƒ PCI Risers  
o The base configuration comes standard with two PCI Risers supporting up  
to five PCI slots. These include:  
¾ One low-profile riser supporting two PCI-Express (PCIe) slots  
¾ One full-height, full-length riser supporting three slots: two PCIe  
x4 and one PCI-X.  
o Additional full-height, full-length risers (below) are supported and  
available as accessories (refer to “Production Spares/Accessories List” in  
section III).  
¾ PCI-X (active): three independent PCI-X, each with maximum 133  
MHz  
¾ PCI-X (passive): two PCI-X with maximum 100 MHz and one PCI-X  
(66 MHz) all on a shared PCI bus  
ƒ HW RAID  
o While SW RAID 0/1/10 is supported on the base configuration, HW RAID 5  
support can be enabled via a set of optional accessories (refer to  
“Production Spares/Accessories List” in section III).  
o Components required are NSCRAID01W (NSC2U RAID5 Kit – includes the I-  
Button (license), battery cable) and the AXXMINIDIMM (128 MB Mini DIMM  
registered DDR-2 for RAID cache.)  
o An additional option is the AXXRSBBU3 (Intel® RAID Smart Battery Backup  
module provides up to 72 hours of cache memory retention when used  
with AXXMINIDIMM). The cable to connect the battery is included in the  
NSCRAID01W kit.  
ƒ Intel® Z-U130 Value Solid State Drive  
o Support for the Intel® Z-U130 Value Solid State Drive is available via a  
selection of optional accessories (refer to “Production Spares/Accessories  
List” in section III).  
o Components required are an Intel® Z-U130 Value Solid State (select  
desired capacity) as well as a mounting kit (TMWVSSDRIVE01W) to mount  
it inside the chassis.  
o Solid state drives are available in several sizes, enabling an array of  
product customization options. These drives securely mount inside the  
chassis offering  
¾ Storage: independent of traditional disk drives  
¾ Boot OS from solid state drive; store data on hard drive  
¾ Store backup image of boot drive  
¾ Add a server partition to the server  
¾ Any other customer design options  
3/28/2008  
v 2.2  
7 of 20  
 
ƒ IO Option Modules  
o These modules, available as optional accessories, attach to the system  
board via a proprietary connector, and provide additional IO through the  
rear bulkhead.  
¾ The AXXGBIOMO option module provides two Gigabit Ethernet NICs.  
¾ The AXXSASIOMOD option module provides one x4 external SAS  
port.  
o For ordering details, refer to “Production Spares/Accessories List” in  
section III.  
ƒ Quad Port Bypass NIC Capability  
o The NSC2U is capable of supporting up to eight ports of front or rear-  
accessible Gigabit Ethernet (either Copper or Fiber) using Quad NIC  
adapters designed by Intel. Optional accessories are available to enable  
these features. For more information and ordering details, refer to  
“Quad Port Bypass NIC Capability” in section IV.  
For more detailed information on the NSC2U, refer to the web links below.  
Additional Product Details  
Check the following web site for more information on the NSC2U:  
Support.Intel.Com Users  
Product information including specifications, compatibility, user’s guides, drivers,  
firmware, and software associated with the Intel® Network Server NSC2U is  
available from Intel Customer Support.  
Intel® Network Server NSC2U Support Web Site  
If you can not access the documents using the links provided, please contact your  
FAE/FSE for assistance.  
3/28/2008  
v 2.2  
8 of 20  
 
Details on Ordering Processors:  
The NSC2U is designed for the Quad-Core Intel® Xeon® 5400 and 5300 processor series,  
and also supports selected SKUs from the Dual-Core Intel® Xeon® 5100 series processors.  
Ordering details for the supported processors for the NSC2U are listed below. These  
include the choice of either Tray (for OEMs) or Boxed (Retail channel) processors.  
Intel® Xeon® Processors Supported by NSC2U:  
Processor  
Number  
E5440  
Long  
Life  
Yes  
Boxed Processor  
Tray Processor  
Product Code  
Cores  
Speed  
TDP  
FSB  
Product Code  
MM#  
MM#  
Quad  
2.83 GHz  
80W  
1333 MHz  
BX80574E5440P 894824  
EU80574KJ073N  
893484  
L5410  
E5345  
E5335  
E5320  
E5310  
5160  
Yes  
Yes  
Yes  
No  
Quad  
Quad  
Quad  
Quad  
Quad  
Dual  
Dual  
Dual  
Dual  
2.33 GHz  
2.33 GHz  
2.00 GHz  
1.86 GHz  
1.60 GHz  
3.00 GHz  
2.33 GHz  
2.00 GHz  
1.86 GHz  
50W  
80W  
80W  
80W  
80W  
80W  
65W  
65W  
40W  
1333 MHz  
1333 MHz  
1333 MHz  
1066 MHz  
1066 MHz  
1333 MHz  
1333 MHz  
1333 MHz  
1066 MHz  
BX80574L5410P 894835  
EU80574JJ053N  
893491  
891115  
891116  
BX80563E5345P 892334 HH80563QJ0538M  
BX80563E5335P 892335 HH80563QJ0418M  
BX80563E5320P 892337 HH80563QH0368M 891118  
BX80563E5310P 892333 HH80563QH0258M 891121  
No  
No  
BX805565160P  
BX805565140P  
BX805565130P  
N/A  
892200  
892169  
884531  
N/A  
HH80556KJ0804M  
HH80556KJ0534M  
HH80556KJ0414M  
HH80556JH0364M  
891706  
891730  
891731  
891704  
5140  
Yes  
Yes  
Yes  
5130  
LV 5128  
Notes:  
ƒ
ƒ
ƒ
Although all of the above processors have been certified on the NSC2U, Intel recommends the  
use of the following processors from Intel’s Embedded Communications and Processor Division  
(ECG) for long availability and support:  
o E5440 (Quad-Core, 2.83 GHz, 1333 MHz FSB, TDP=80 W)  
o L5410 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=50W)  
o E5345 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=80 W)  
o E5335 (Quad-Core, 2.00 GHz, 1333 MHz FSB, TDP=80 W)  
o 5140  
o 5130  
(Dual-Core, 2.33 GHz, 1333MHz FSB, TDP=65W)  
(Dual-Core, 2.00 GHz, 1333MHz FSB, TDP=65W)  
o LV 5128 (Dual-Core, 1.86 GHz, 1066MHz FSB, TDP=40W)  
Heatsinks  
o This product requires Passive heatsinks. The boxed processors listed above include a  
Passive Heatsink Kit, made of aluminum. Do not use Active Fan Heatsinks, which are  
provided in some Retail Boxed Processors.  
o For Tray processors, you will need to procure a Heatsink for each processor (see  
NSCSNKCLP01 in the Spares/Accessories list below). This is a copper heatsink. There  
are no clips needed for this heatsink, since the heatsink includes captive screws.  
o If ordering other Boxed Processors (not listed here), do not use the fansink, which  
might be included.  
Note that processor product codes can change, and that the above is a snapshot current as of  
3/28/2008. Please consult with your Intel representative for SSpec or MM# which might be  
needed for ordering the processor. Any differences in functionality are reported in the  
Monthly Specification updates available at http://developer.intel.com.  
3/28/2008  
v 2.2  
9 of 20  
 
III. Production Spares/Accessories List  
Below are the Spare parts and Accessories that can be ordered with the NSC2U system.  
Any of these parts can be ordered as spares for part replacement purposes or as additional  
customer inventory. Some of the parts below are not included in the NSC2U system base  
model and can be ordered as accessories for purposes of upgrading the base model to  
include additional features.  
For a listing of additional compatible accessories, such as Optical Devices for use with the  
CD-ROM carrier, please refer to the Tested Hardware and Operating System List (THOL).  
Included in  
Base Model MM#  
(Y/N)  
Min.  
Order  
Qty  
PID Order Code  
Description  
Contents  
Y (one in AC  
880110  
SKU)  
AC power supply  
TIGI2U AC Power Supply  
TIGI2U DC Power Supply  
NSC2U Processor Heatsink  
1
1
1
TLIACPSU003  
TLIDCPSU003  
NSCSNKCLP01  
DC power supply,  
input power connector  
Y (one in DC  
880116  
SKU)  
Heat sink (copper)  
N
891200  
12  
Bezel, packaged in  
cartons of 12  
Y
(order in  
multiples  
of 12)  
NSC2U Bezel (Unpainted), 12-pack  
NSCBEZEL01W  
889820  
(one bezel)  
Unpainted blank  
48  
2 blank panels  
installed in base  
model  
NSC2U Blank Escutcheons (unpainted)  
– 48 pack  
escutcheon panel  
(filler panel if front-  
NICs are not present)  
(order in  
multiples  
of 48)  
NSCESCBLNK01W  
HW RAID  
897011  
890202  
I-Button (license),  
battery cable (battery  
or mini-DIMM not  
included)  
NSC2U RAID5 Kit  
N
N
1
5
NSCRAID01W  
Intel® RAID Smart Battery Backup  
module: for use with Intel® Integrated  
Server RAID (requires NSCRAID01W  
plus mini DIMM), provides up to 72  
hours of cache memory retention when  
used with AXXMINIDIMM.  
(order in  
multiples  
of 5)  
Battery backup kit  
Mini-DIMM  
AXXRSBBU3  
883471  
881258  
5
128 MB Mini DIMM registered DDR-2  
for RAID cache. Note: enabling RAID  
capability also requires Intel RAID  
Activation Key– NSCRAID01W  
(order in  
multiples  
of 5)  
N
AXXMINIDIMM  
Remote Management  
Intel® Remote Management Module 2  
(RMM2) - Single Pack  
RMM2 with GCM  
(single-pack)  
N
N
1
AXXRMM2  
894383  
894385  
1
(specify  
‘1’ for  
Intel Remote Management Module 2  
(RMM2) – 10-Pack  
RMM2 with GCM (10-  
pack)  
AXXRMM2BULK  
each 10-  
pack)  
3/28/2008  
v 2.2  
10 of 20  
 
 
Production Spares/Accessories List (continued)  
Included in  
Min.  
Order  
Qty  
MM#  
PID Order Code  
Description  
Contents  
Base Model  
(Y/N)  
PCI Risers and I/O Options  
SR2400 (2U) Full Height PCI-Express  
riser (two PCI-Express slots, one PCI-  
X slot)  
Riser  
Riser  
Y
1
ASR2500FHR  
880515  
SR2500 (2U) Full Height PCI-X  
"active" high performance riser card  
(three PCI-X slots)  
N
N
1
1
ADRACTRIS  
ADRPCIXRIS  
856546  
863135  
SR2500 (2U) Full Height PCI-X  
“passive” riser card (three PCI-X slots)  
Riser  
Riser  
Two-slot Low Profile PCI-Express riser  
Dual Gigabit Ethernet I/O Module  
Y
N
N
1
1
1
FSR2500LPR  
880516  
880518  
880517  
Dual Gigabit rear  
ports  
AXXGBIOMOD  
Four-port external SAS I/O Expansion  
Module  
x4 external rear port  
AXXSASIOMOD  
Solid State Drives  
Mounting kit for Intel® Z-U130  
Value Solid State Drive  
Interposer board,  
cable, mounting  
screws (flash drive  
not included)  
N
1
TMWVSSDRIVE01W  
893165  
Requires Intel® Z-U130 Value Solid State  
Drive (purchased separately).  
Intel® Z-U130 Value Solid State Drive  
- 1 GB, Low Profile Connector  
1 GB Module – Low  
Profile Connector  
N
N
N
10  
10  
10  
SSDUSMS0001GL10  
SSDUSMS0002GL10  
SSDUSMS0004GL10  
890945  
890943  
890941  
Requires TMWVSSDRIVE01W  
Intel® Z-U130 Value Solid State Drive  
– 2 GB, Low Profile Connector  
2 GB Module – Low  
Profile Connector  
Requires TMWVSSDRIVE01W  
Intel® Z-U130 Value Solid State Drive  
- 4 GB, Low Profile Connector  
4 GB Module – Low  
Profile Connector  
Requires TMWVSSDRIVE01W  
Spares  
Power distribution  
board, with integrated  
wire harness  
NSC2U Power Distribution Board  
Y
Y
1
1
NSCPWRDISBDW  
889805  
889812  
NSC2U Front Panel IO Board with LED  
pipe  
Board, set of front  
panel light pipes  
NSCFPIOBDLPW  
Board  
NSC2U T5000PAL Server board  
NSC2U SAS Backplane  
NSC2U Bridge board  
Y
Y
Y
1
1
1
NSCSASBSBDW  
NSCSASBKPLNW  
NSCBRIDGEBDW  
889828  
889829  
889852  
Backplane  
Board, insulator  
3/28/2008  
v 2.2  
11 of 20  
 
Production Spares/Accessories List (continued)  
Included in  
Min.  
Order  
Qty  
MM#  
PID Order Code  
Description  
Contents  
Base Model  
(Y/N)  
Spares  
Flex cable (SAS  
interface, front panel  
signals), front panel  
power cable, serial  
port cable, CD-ROM  
cable, alarm cable,  
TAM module cable  
NSC2U System Interconnect Cable Kit  
Y
1
NSCCBLMSCW  
889819  
80 mm CPU fans (2),  
40 mm PCI fans (2),  
plastic fasteners (8)  
NSC2U Fan Assembly (set of four)  
NSC2U DVD Drive Engagement Tab  
Y
Y
1
1
NSCFANSETW  
889822  
889845  
Blue plastic  
engagement bracket  
and black plastic  
locking clip, screws  
NSCDVDENGTABW  
10  
Carrier, black plastic  
filler, screws (4)  
(order in  
multiples  
of 10)  
TIGW1U SAS HDD carrier  
Y
FXX25HDDCAR  
881681  
Note: There are also accessories/spares specific to Quad Port Bypass NIC capability. For  
these items, please refer to Section IV “Quad Port Bypass NIC Capability”.  
3/28/2008  
v 2.2  
12 of 20  
 
IV. Quad Port Bypass NIC Capability  
This section is intended for customers that plan to use the Quad Port NIC with Bypass  
capability on the NSC2U. It describes what parts must be ordered to enable this capability.  
The NSC2U is capable of supporting:  
Up to eight ports of front-accessible Gigabit Ethernet (either Copper or Fiber) using  
Quad NIC adapters designed by Intel. The front-accessible NIC configuration also  
requires the purchase of an internal cabling/mounting kit including an escutcheon for  
securing the front ports.  
Up to eight ports of rear-accessible Gigabit Ethernet (Copper or Fiber) using Quad NIC  
adapters also designed by Intel.  
The Quad Bypass adapters and the cabling/mounting kits come in packages of five units  
each. These kits include five of the NIC cables designed for the NSC2U system, as well as  
the escutcheons, cable management bracket, and associated screws to complete the  
installation of the Bypass adapter in the system. Also there are bulk pack (48 count)  
escutcheon kits (copper, fiber, and filler panel) available to streamline the customization  
and painting process of the system.  
Below are the Accessories that may be ordered to enable the Quad Port Bypass NIC  
capability on the NSC2U system. Note: For a list of other tested Network Interface Cards  
(NICs) refer to the Tested Hardware and Operating System List (THOL).  
Included in  
Base Model MM#  
(Y/N)  
Min.  
Order  
Qty  
PID  
Order Code  
Description  
Contents  
Copper NIC  
Quad-port design,  
based on two Intel®  
82571GB dual-port  
PCI Express*  
Intel® PRO/1000 PT Quad Port  
Bypass Adapter (Copper)  
– 5 Pack  
EXPI9014PTBLK  
(Bypass rear access)  
N
N
5
876697  
876699  
GbE controllers  
Quad-port design,  
based on two Intel®  
82571GB dual-port  
PCI Express*  
Intel® PRO/1000 PT Quad Port  
Bypass Adapter (Copper, NIC-in-  
Front) – 5 Pack  
EXPI9024PTBLK  
(Bypass NIC-in-front)  
5
5
GbE controllers  
Quad NIC-in-front  
cable assembly,  
escutcheon and  
screws for copper  
ports, cable  
NSC2U Quad NIC-in-Front  
Mounting Kit (Copper) – 5 Pack  
N
N
NSCCBLFNICW  
890325  
(order in  
multiples  
of 5)  
management bracket  
and screw  
Unpainted  
48  
escutcheons for use  
with NSCCBLFNICW  
Intended for prep  
(painting) purposes.  
Note: Five  
escutcheons are  
included in  
NSC2U Escutcheons for Copper  
ports (unpainted) – 48 Pack  
(order in  
multiples  
of 48)  
NSCESCCPR01W  
898020  
NSCCBLFNICW  
3/28/2008  
v 2.2  
13 of 20  
 
 
Included in  
Base Model MM#  
(Y/N)  
Min.  
Order  
Qty  
PID  
Order Code  
Description  
Contents  
Fiber NIC  
Quad-port design,  
based on two Intel®  
82571GB dual-port  
PCI Express*  
EXPI9014PFBLK  
(Bypass rear access)  
Intel® PRO/1000 PF Quad Port  
Bypass Adapter (Fiber) – 5 Pack  
N
N
5
876696  
876694  
GbE controllers  
Quad-port design,  
based on two Intel®  
82571GB dual-port  
PCI Express*  
Intel® PRO/1000 PF Quad Port  
Bypass Adapter (Fiber, NIC-in-  
Front) – 5 Pack  
EXPI9024PFBLK  
(Bypass NIC-in-front)  
5
5
GbE controllers  
Quad NIC-in-front  
escutcheon, and LED  
cable for fiber ports,  
cable management  
bracket and screw  
NSC2U Quad NIC-in-Front  
Mounting Kit (Fiber) – 5 Pack  
N
NSCCBLFNICFBRW  
NSCESCFBR01W  
897002  
898021  
(order in  
multiples  
of 5)  
Unpainted  
escutcheons for use  
with  
NSCCBLFNICFBRW  
Intended for prep  
(painting) purposes.  
N
48  
Note: Five  
escutcheons are  
included in  
NSCCBLFNICFBRW  
NSC2U Escutcheons for Fiber  
ports (unpainted) – 48 Pack  
(order in  
multiples  
of 48)  
Miscellaneous  
48  
Unpainted blank  
2 blank panels  
installed in base  
model  
NSC2U Escutcheons filler panel  
(unpainted) – 48 pack  
escutcheon panel  
(filler panel if front-  
NICs are not present)  
(order in  
multiples  
of 48)  
NSCESCBLNK01W  
897011  
Overview of Intel® PRO/1000 Quad Port Bypass Server Adapters:  
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters provide in-line server  
appliances, such as Intrusion Protection Servers (IPSes), with high-performance, low-latency,  
in-line connectivity, and a bypass mode to ensure business continuity. These adapters also use  
the PCI Express* serial bus for greater throughput, and they support Intel® I/O Acceleration  
Technology (Intel® I/OAT) for further performance enhancement, including the reduced  
overhead so important to IPS applications.  
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters are intended for use by  
equipment manufacturer hardware designers in application-specific in-line server appliances,  
where a bypass mode is desirable. Given that equipment manufacturers typically write specific  
software applications for their in-line platforms, Intel only provides open source reference  
drivers for these adapters. Interested hardware designers may contact their local Intel  
representative for additional product or purchase information.  
More information on Intel® PRO/1000 Quad Port Bypass Server Adapters is available at:  
3/28/2008  
v 2.2  
14 of 20  
 
Appendix A. Rack Mounting Options for 1U and 2U  
Intel® Communications Rack Mount Servers  
Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for this  
product. Please refer to the tables below for the correct options to suit your needs.  
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack Mount  
Servers. Installation instructions are included in each kit.  
2-post Rack Mounting Kit Options  
Rack width  
Post depth  
Rack fastener hole spacing  
Applicable kits:  
19 inch  
23 inch  
3 inch  
5 inch  
EIA-Wide  
EIA-Universal ETSI  
TMLCMOUNT21  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
4-post Rack Mounting Kit Options  
Front-post to  
Rack fastener  
hole spacing  
Rack width  
rear-post distance  
Applicable kits:  
Min  
(inches)  
Max  
(inches)  
EIA-  
Wide  
EIA-  
Universal  
19 inch  
23 inch  
ETSI  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
TMLPSLIDE01†  
20  
20  
24  
24  
20  
24  
22.5  
28 or 34††  
The TMLPSLIDE01 kit contains server securing brackets. The rails and other options for  
mounting the server are available through other venders such as Accuride  
††34-inch span requires the optional Accuride "Long Bracket" kit.  
3/28/2008  
v 2.2  
15 of 20  
 
 
TMLCMOUNT21  
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-post,  
central office type, 19-inch wide rack. This kit consists of L-shaped brackets that fasten to  
the sides of the server and to the rack.  
TMLCMOUNT21  
3/28/2008  
v 2.2  
16 of 20  
 
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52  
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2-  
post or 4-post racks.  
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19-inch wide racks.  
These racks are considered standard EIA (universal hole spacing) racks.  
TMLPMOUNT52 is used for mounting servers on 23-inch wide racks. These racks could be  
standard EIA (universal or wide hole spacing) or ETSI (European) racks.  
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although the  
mounts are designed as rails, they are not sliding rails. This means the servers can be slid  
into the racks for installation purpose, but the rails are not designed to support a mounted  
server during service.  
TMLPMOUNT4x/5x Feature Comparison  
Plastic  
strips2  
Not  
included  
Side  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
No1  
Yes  
Yes  
EIA-Universal  
Interference  
No Interference  
N/A  
access6  
Xylan  
EIA-Wide or EIA-  
Universal4  
Front  
access  
Included5  
Included5  
coating3  
Xylan  
EIA-Wide, EIA-  
Universal or ETSI  
Front  
access  
coating3  
Notes:  
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server with one's hands  
when sliding it out of the rack; otherwise, the server could fall to the ground as it is being  
removed.  
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations. The result of  
this is that the parts are usable, but the server could have somewhat of a "scrape-in feel" rather  
than "slide in". Also, the rails will fit sloppier, so the side-located chassis securing screws could  
be difficult to align in 2-post installations. Replacement material is available from the plastic  
strip manufacturer.  
3. Xylan is a tough, low-friction coating similar to Teflon.  
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-Universal.  
TMLPMOUNT51 contains an adapter bracket to overcome this EIA-Wide issue.  
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot when there is  
already equipment installed both above and below that open slot.  
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post racks.  
3/28/2008  
v 2.2  
17 of 20  
 
The diagrams above summarize the components and “slide-in rail-type” system of the  
TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.  
3/28/2008  
v 2.2  
18 of 20  
 
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is that the  
TMLPMOUNT41 series uses a screw to lock the server in place using the Universal  
Mounting Bracket, whilst the TMLPMOUNT51/52 series has an additional Slide Pull-Out  
Locking feature.  
Universal Front Mounting Bracket on the TMLPMOUNT41  
Slide Pull-Out Locking feature on the TMLPMOUNT51/52  
3/28/2008  
v 2.2  
19 of 20  
 
TMLPSLIDE01  
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide rails to  
produce a rack mounted serviceable server. The TMLPSLIDE01 kit contains two Universal  
Front Mounting Brackets that secure the server to the front of the rack. The sliding rails  
and optional mounting brackets required to mount the server must be purchased through  
the channel. For example, the Accuride 22-inch Model 305A-LR slide rails are designed to  
mount a server for “in-rack service.” This example would also use an Accuride mounting  
bracket kit and the TMLPSLIDE01.  
Universal Front Mounting Bracket with securing tab  
Note: Using slide rails could result in non-compliance with Seismic Zone 4 requirements of  
NEBS-3 certification.  
Ordering Information  
Minimum Order  
PID  
Non-RoHS MM#  
RoHS MM#  
Quantity  
TMLCMOUNT21  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
TMLPSLIDE01  
862501  
838890  
851760  
851745  
845583  
881904  
881907  
881934  
881935  
881915  
10  
10  
1
1
10  
Customers should order RoHS items for shipments going to the European Union (EU).  
Although these mounts have been designed for industry standard racks, please consult  
with your Intel Field Application or Sales Engineer before selecting racks for these servers.  
Compatible rack mounting kits can also be obtained from 3rd party suppliers.  
3/28/2008  
v 2.2  
20 of 20  
 

Jet Tools Air Cleaner AFS 1000B User Manual
JVC CRT Television C 13310 User Manual
Kenwood Car Stereo System KCA 20FM User Manual
Kenwood Two Way Radio TK 6110 User Manual
Keys Fitness Treadmill 1350 User Manual
KitchenAid Ice Maker KUIS185EAL0 User Manual
Kodak Digital Camera AFi II User Manual
Konica Minolta Drums CM 2500d User Manual
Konica Minolta Two Way Radio FRS 1000 User Manual
Korg Recording Equipment krog User Manual