Ingersoll Rand Water Pump 650517 User Manual

650517  
OPERATOR’S MANUAL  
650518  
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE  
ALSO INCLUDE MANUALS: PH10AĆXĆX HIGH PRESSURE DIAPHRAGM PUMP (PN 97999Ć801), 6661MXĆXĆC DIAPHRAGM PUMP  
(PN 97999Ć619), L262X1ĆXXX REGULATOR (PN 100400Ć7), P292X1ĆXXX PIGGYBACK FILTER / REGULATOR (PN 100400Ć8).  
RELEASED: 4-10-97  
REVISED:  
(REV. C)  
9-15-00  
650517 & 650518  
DELIVERY SYSTEM  
1” DIAPHRAGM PUMP, 3:1 RATIO, WITH WALL MOUNT  
SERVICE KITS  
OPERATING INSTRUCTIONS  
Use only genuine ARO replacement parts to assure compatible presĆ  
sure rating and longest service life.  
WARNING DO NOT EXCEED MAXIMUM OPERATING PRESĆ  
SURE OF 300 P.S.I. (20.4 BAR) AT 100 P.S.I. (6.9 BAR) AIR INĆ  
LET PRESSURE.  
Fluid Section Repair Kit 637179.  
Air Section Repair Kit 637178.  
Refer to the 6661MXĆXĆC Operator's Manual for parts / repair and serĆ  
vice information (model 650517).  
WARNING READ THE PUMP MANUAL FOR ADDITIONAL  
OPERATING AND SAFETY PRECAUTIONS AND OTHER IMĆ  
PORTANT INFORMATION.  
Refer to the PH10AĆXĆX Operator's Manual for parts / repair and serĆ  
vice information (model 650518).  
INITIAL SETUP PROCEDURE  
PUMP SYSTEM DATA  
Install the connector to the air supply hose.  
Attach (17) ground kit to ground lug.  
Attach the ground wire to a suitable ground.  
Keep containers covered to prevent contamination.  
When using an agitator, install a T" at the air inlet or use a sepĆ  
arate air supply source.  
System Model . . . . . . . . . . 650517(aluminum)  
650518 (stainless steel)  
Basic Pump Model . . . . . 6661M0Ć2A4ĆC (aluminum)  
PH10AĆASSĆSST (stainless steel)  
Pump Type . . . . . . . . . . . 3:1 Ratio, Metallic Air Operated Double  
Diaphragm with stainless steel seats  
Material . . . . . . . . . . . . . . Aluminum  
START-UP  
Air Inlet . . . . . . . . . . . . . . 3/8" Ć 18 N.P.T.F.  
Maximum Air Inlet Pressure 100 p.s.i.g. (6.9 bar)  
Maximum Outlet Pressure 300 p.s.i.g. (20.4 bar)  
Maximum Flow Rate . . . . 24 g.p.m. (90.7l/m)  
Maximum Particle Size . . 1/8" (3.2 mm)  
1. Turn the knob on the air regulator counterclockwise to zero p.s.i.  
2. Place (11) tube into the container of material.  
3. Start the pump to cycle by turning the air regulator knob clockwise.  
The pump will cycle several strokes until pressure is built up in the  
system, at which time it will stop. Check for any loose fittings or  
leakage.  
Maximum Temp. Limits . . 35_ to 150_F (2_ to 66_C)  
Noise Levelh . . . . . . . . . . 84.5 db(A) @ 70 psi, 60 cycles per minute.  
h ThepumpsoundpressurelevelspublishedherehavebeenupdatedtoanEquivalentContinuousSoundLevel  
(L ) to meet the intent of ANSI S1.13Ć1971, CAGIĆPNEUROP S5.1 using four microphone locations.  
Aeq  
GENERAL DESCRIPTION  
The 650517& 650718 Wall Mount Pumping System includes fittings,  
wall bracket, regulator, siphon tube, gauge and hardware.  
The diaphragm pump uses stainless steel balls and seats, and teflon  
diaphragms and is designed to be used with waterborne paints. The  
gun and low pressure air and material hoses are not included.  
INGERSOLL-RAND COMPANY  
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 43506Ć0151  
&
(419) 636-4242  
D
FAX (419) 633-1674  
E2000 D PRINTED IN U.S.A.  
 

Indesit Cooktop KG6044WV G User Manual
Indesit Washer WI 101 User Manual
IOGear Network Card GBU421 User Manual
John Deere Compact Loader 544J User Manual
JVC Computer Monitor GM X50S User Manual
JVC Stereo System UX T150 User Manual
Kaidan Camcorder Accessories Digital Camera Tripod User Manual
Kalorik Coffeemaker USK CM 4 User Manual
Kidde Carbon Monoxide Alarm KN COPF I User Manual
Kobe Range Hoods Ventilation Hood IS2036GS User Manual