650517
OPERATOR’S MANUAL
650518
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
ALSO INCLUDE MANUALS: PH10AĆXĆX HIGH PRESSURE DIAPHRAGM PUMP (PN 97999Ć801), 6661MXĆXĆC DIAPHRAGM PUMP
(PN 97999Ć619), L262X1ĆXXX REGULATOR (PN 100400Ć7), P292X1ĆXXX PIGGYBACK FILTER / REGULATOR (PN 100400Ć8).
RELEASED: 4-10-97
REVISED:
(REV. C)
9-15-00
650517 & 650518
DELIVERY SYSTEM
1” DIAPHRAGM PUMP, 3:1 RATIO, WITH WALL MOUNT
SERVICE KITS
OPERATING INSTRUCTIONS
Use only genuine ARO replacement parts to assure compatible presĆ
sure rating and longest service life.
WARNING DO NOT EXCEED MAXIMUM OPERATING PRESĆ
SURE OF 300 P.S.I. (20.4 BAR) AT 100 P.S.I. (6.9 BAR) AIR INĆ
LET PRESSURE.
•
•
Fluid Section Repair Kit 637179.
Air Section Repair Kit 637178.
Refer to the 6661MXĆXĆC Operator's Manual for parts / repair and serĆ
vice information (model 650517).
WARNING READ THE PUMP MANUAL FOR ADDITIONAL
OPERATING AND SAFETY PRECAUTIONS AND OTHER IMĆ
PORTANT INFORMATION.
Refer to the PH10AĆXĆX Operator's Manual for parts / repair and serĆ
vice information (model 650518).
INITIAL SETUP PROCEDURE
PUMP SYSTEM DATA
•
•
•
•
•
Install the connector to the air supply hose.
Attach (17) ground kit to ground lug.
Attach the ground wire to a suitable ground.
Keep containers covered to prevent contamination.
When using an agitator, install a T" at the air inlet or use a sepĆ
arate air supply source.
System Model . . . . . . . . . . 650517(aluminum)
650518 (stainless steel)
Basic Pump Model . . . . . 6661M0Ć2A4ĆC (aluminum)
PH10AĆASSĆSST (stainless steel)
Pump Type . . . . . . . . . . . 3:1 Ratio, Metallic Air Operated Double
Diaphragm with stainless steel seats
Material . . . . . . . . . . . . . . Aluminum
START-UP
Air Inlet . . . . . . . . . . . . . . 3/8" Ć 18 N.P.T.F.
Maximum Air Inlet Pressure 100 p.s.i.g. (6.9 bar)
Maximum Outlet Pressure 300 p.s.i.g. (20.4 bar)
Maximum Flow Rate . . . . 24 g.p.m. (90.7l/m)
Maximum Particle Size . . 1/8" (3.2 mm)
1. Turn the knob on the air regulator counterclockwise to zero p.s.i.
2. Place (11) tube into the container of material.
3. Start the pump to cycle by turning the air regulator knob clockwise.
The pump will cycle several strokes until pressure is built up in the
system, at which time it will stop. Check for any loose fittings or
leakage.
Maximum Temp. Limits . . 35_ to 150_F (2_ to 66_C)
Noise Levelh . . . . . . . . . . 84.5 db(A) @ 70 psi, 60 cycles per minute.
h ThepumpsoundpressurelevelspublishedherehavebeenupdatedtoanEquivalentContinuousSoundLevel
(L ) to meet the intent of ANSI S1.13Ć1971, CAGIĆPNEUROP S5.1 using four microphone locations.
Aeq
GENERAL DESCRIPTION
The 650517& 650718 Wall Mount Pumping System includes fittings,
wall bracket, regulator, siphon tube, gauge and hardware.
The diaphragm pump uses stainless steel balls and seats, and teflon
diaphragms and is designed to be used with waterborne paints. The
gun and low pressure air and material hoses are not included.
INGERSOLL-RAND COMPANY
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 43506Ć0151
&
(419) 636-4242
D
FAX (419) 633-1674
E2000 D PRINTED IN U.S.A.
|